文献速递主动脉疾病

传统血管腔内动脉瘤修复(EVAR)移植物主动脉分叉抬高后3型内漏的全血管腔内衬里术单中心病例系列

A Single-Institution Case Series of Total Endovascular Relining for Type 3 Endoleaks in Traditional Endovascular Aneurysm Repair (EVAR) Grafts with Raised Bifurcations.
PubMed 文献 · Ann Vasc Surg · 2023-10-13

单中心回顾性分析4例既往EVAR移植物主动脉分叉抬高后需干预的内漏患者,采用Ovation支架移植物行全血管腔内衬里术,技术成功率100%,随访无1型或3型内漏,1例因动脉瘤增长和2型内漏再干预,平均随访2.44年,动脉瘤相关死亡率0%,全因死亡率25%。

要点

  • 对主动脉分叉抬高的既往EVAR移植物3型内漏,可采用Ovation支架移植物行全血管腔内衬里术。
  • 本组4例技术成功率100%,随访无1型或3型内漏。
  • 1例因动脉瘤增长和2型内漏需再干预,平均随访2.44年全因死亡率25%。

核心结论

  • 作者采用Ovation支架移植物对既往移植物主动脉分叉抬高的3型内漏患者行血管腔内衬里术,随访影像未见1型或3型内漏。
  • 作者认为该方法可能使3型内漏患者获得此前不具备的微创经皮入路选择。

研究设计与样本

  • 单中心病例系列,纳入既往置入主动脉分叉抬高移植物后发生内漏需干预的患者4例。
  • 主要结局为技术成功(置入所有计划器械)、3型内漏消除、随访动脉瘤大小及再干预需求。
  • 次要结局为30天并发症、动脉瘤相关死亡率和全因死亡率。

主要发现

  • 4例患者均为男性,衬里术时平均年龄84.5岁,初次手术至衬里术均至少间隔10年。
  • 3例初始为AneuRx血管腔内动脉瘤修复,1例为Gore与Cook移植物组合。
  • 技术成功率100%,随访无1型或3型内漏,1例因动脉瘤增长和2型内漏再干预。
  • 术后并发症1例为需求性缺血继发心功能障碍,动脉瘤相关死亡率0%,平均随访2.44年全因死亡率25%。

临床怎么用

  • 作者描述的技术包括:Ovation器械台面释放、修改释放系统系绳、预置上翻0.014″导丝并经对侧抓捕外化,使主体座于分叉处后按说明书完成释放。
  • 作者认为该方法可能为3型内漏患者提供微创经皮入路选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The endovascular repair of infrarenal abdominal aortic aneurysms can be performed with a wide variety of devices. Many of these grafts elevate the aortic bifurcation which can limit future repairs if the graft material fails thereby creating a type III endoleak to aorto-uniliac grafts. Many manufacturers have grafts susceptible to this, but we have seen this in the Medtronic AneuRx graft. Our goal is to provide technical details and outcomes regarding a novel technique to reline these grafts while maintaining inline flow to the iliac arteries. METHODS: This was a single-institution review of patients who had endoleaks requiring intervention after a previously placed graft with an elevated aortic bifurcation. Primary outcomes included technical success defined as placement of all planned devices, resolution of type III endoleak, aneurysm size at follow-up, and requirement of reintervention. Secondary outcomes included 30-day complications, aneurysm-related mortality, and all-cause mortality. Technical details of the operation include back-table deployment of an Ovation device, modification of the deployment system tether and pre-emptive placement of an up and over 0.014″ wire. The wire is placed up and over and hung outside the contralateral gate. Once the main body is introduced above the old graft, the 0.014" is snared from the contralateral side and externalized. The main body is then able to be seated at the bifurcation as the limb is not fully deployed and then device deployment is completed per instructions for use. RESULTS: Our study consists of 4 individuals, 3 of which had an abdominal aortic aneurysm initially managed with an AneuRx endovascular aneurysm repair and 1 with a combination of Gore and Cook grafts. All 4 patients were male with an average age of 84.5 years at time of reline. All patients had at least 10 years between initial surgery and reline at our institution. Primary outcomes revealed no type 1 or 3 endoleaks at follow-up, technical success was 100% and 1 patient required reintervention for aneurysm growth and type 2 endoleak. In terms of our secondary outcomes, there was 1 postoperative complication which was cardiac dysfunction secondary to demand ischemia, aneurysm-related mortality was 0% and all-cause mortality was 25% at average follow-up of 2.44 years. CONCLUSIONS: As individuals continue to age, there are more patients who would benefit from less invasive reinterventions following endovascular aneurysm repair. Whether this is due to aortic degeneration, stent migration, or stent material damage is not always known. In this study, we present an endovascular approach to treating type III endoleak patients with a previous graft and elevated aortic bifurcation using Ovation stent grafts and found no evidence of type 1 or 3 endoleaks on follow-up imaging. This approach may allow patients with type III endoleak the option of a minimally invasive, percutaneous approach where they previously would not have had one.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Patel RJ, Sibona A, Malas MB, et al. A Single-Institution Case Series of Total Endovascular Relining for Type 3 Endoleaks in Traditional Endovascular Aneurysm Repair (EVAR) Grafts with Raised Bifurcations. Ann Vasc Surg. 2023. PMID: 37839654. doi:10.1016/j.avsg.2023.08.038

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。