开窗腔内主动脉修复术中开窗与靶血管错位的临床影响及决定因素
这项单中心回顾性研究(2014-2022年)纳入65例接受开窗腔内主动脉修复术(FEVAR)的肾旁、肾周或胸腹主动脉瘤患者中的60例(202条靶动脉),分析开窗与靶血管错位的临床影响及决定因素。结果显示水平错位>15°与靶血管不稳定显著相关(HR 5.19),而垂直错位无显著影响;肾旁主动脉角度、桥接距离>5 mm及高-profile支架在迂曲髂动脉入路中的使用与临床显著错位相关。
要点
- 水平错位>15°与靶血管不稳定显著相关(HR 5.19;95%CI 1.54-17.48;p=.008)。
- 垂直错位对靶血管不稳定无显著影响(HR 0.99;95%CI 0.56-1.73;p=.97)。
- 桥接距离>5 mm、基线错位程度及原发内漏持续>6个月与随访期间错位增加相关。
核心结论
- 水平错位>15°与靶血管结局恶化相关,可能由髂动脉入路过曲、肾旁主动脉角度过大及桥接距离>5 mm所致。
研究设计与样本
- 单中心回顾性研究(2014-2022年),纳入65例接受FEVAR的肾周、肾旁或胸腹主动脉瘤患者中的60例(202条靶动脉),其中肾周/肾旁占80%、胸腹占20%。
主要发现
- 平均水平错位为9±12°(中位数5°;IQR 0-16),平均垂直错位为0.7±1 mm(中位数0 mm,IQR 0-1)。
- 36个月时免于靶血管不稳定(TVI)为92%(95%CI 88-98)。
- 水平错位>15°与TVI显著相关(HR 5.19;95%CI 1.54-17.48;p=.008);垂直错位对TVI无显著影响(HR 0.99;95%CI 0.56-1.73;p=.97)。
- 多变量分析显示,肾旁主动脉角度(每增加1度OR 1.01;95%CI 1.00-1.02;p=.044)、桥接距离>5 mm(OR 1.07;95%CI 1.02-1.11;p=.003)及在迂曲髂动脉入路中使用高-profile支架(OR 7.55;95%CI 4.55-1.11;p=.003)与临床显著错位相关。
- 桥接距离>5 mm(OR 2.00;95%CI 1.02-11.29;p=.044)、基线错位程度(OR 1.04;95%CI 1.01-1.08;p=.036)及原发内漏持续>6个月(OR 5.85;95%CI 1.23-29.1;p=.023)与随访期间错位增加相关。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This single centre, retrospective study (2014 - 2022) on juxta-, pararenal, or thoraco-abdominal aortic aneurysms treated by fenestrated endovascular aortic repair (FEVAR) was conducted to investigate the clinical impact and determinants of fenestration to target vessel misalignment in FEVAR. METHODS: Pre-operative supracoeliac, pararenal, and infrarenal aortic angles were measured on three dimensional computed tomography angiography (CTA) reconstructions. Two components of misalignment were measured on the first post-operative CTA: horizontal misalignment (angle between the fenestration and the target vessel ostium on perpendicular CTA cuts) and vertical misalignment (vertical distance between the fenestration and the target vessel at its origin). Endpoints were freedom from target vessel instability (TVI) and alignment change over time. RESULTS: Of 65 patients treated by FEVAR, 60 (202 target arteries) with juxta-, pararenal (80%), or thoraco-abdominal aortic aneurysm (20%) were included. Mean horizontal misalignment was 9 ± 12° (median 5°; IQR 0 - 16) and mean vertical misalignment was 0.7 ± 1 mm (median 0 mm, IQR 0 - 1). Freedom from TVI was 92% (95% CI 88 - 98) at 36 months. Horizontal misalignment > 15° was significantly associated with TVI (HR 5.19; 95% CI 1.54 - 17.48; p = .008); vertical misalignment did not significantly impact TVI (HR 0.99; 95% CI 0.56 - 1.73; p = .97). By multivariable analysis, pararenal aortic angle (OR 1.01 per increased degree of angulation; 95% CI 1.00 - 1.02; p = .044), bridging distance > 5 mm (OR 1.07; 95% CI 1.02 - 1.11; p = .003), and use of higher profile endografts in tortuous iliac access (OR 7.55; 95% CI 4.55 - 1.11; p = .003) were associated with clinically significant misalignment. Bridging distance > 5 mm (OR 2.00; 95% CI 1.02 - 11.29; p = .044), degree of baseline misalignment (OR 1.04; 95% CI 1.01 - 1.08; p = .036), and persistence of any primary endoleak for > 6 months (OR 5.85; 95% CI 1.23 - 29.1; p = .023) were associated with misalignment increase during follow up. CONCLUSION: Horizontal misalignment > 15° is associated with worsened target vessel outcomes. This may occur as a result of excessive iliac access tortuosity, high pararenal aortic angulation, and bridging distance > 5 mm.
引用
- Squizzato F, Piazza M, Forcella E, et al. Clinical Impact and Determinants of Fenestration to Target Vessel Misalignment in Fenestrated Endovascular Aortic Repair. Eur J Vasc Endovasc Surg. 2023. PMID: 37858703. doi:10.1016/j.ejvs.2023.10.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。