文献速递主动脉疾病

腹主动脉瘤腔内修复术(EVAR)后肢体闭塞的相关因素

Factors Related to Limb Occlusion After Endovascular Abdominal Aortic Aneurysm Repair (EVAR).
PubMed 文献 · Ann Vasc Surg · 2023-10-17

这项病例对照研究回顾性分析了2个中心2007—2017年11年间连续接受EVAR的患者,共787例(男性702例,中位年龄78岁,范围53—94岁),50例发生肢体闭塞,总体肢体闭塞率为6.35%。髂支支架过度放大超过自体血管直径10%、髂外动脉锚定区和术后扭结在闭塞组更常见,髂支支架过度放大在闭塞组显著大于对照组(P < 0.001),回归分析中仍显著;Cook支架的肢体闭塞率为9%,Medtronic和Vascutek分别为2.4%和2.5%。作者认为髂支过度放大超过20%可能是EVAR后肢体闭塞的促进因素,应审慎选择放大比例。

要点

  • 787例EVAR患者总体肢体闭塞率为6.35%(50/787)。
  • 髂支支架过度放大在闭塞组显著大于对照组(P < 0.001),回归分析仍显著。
  • Cook支架肢体闭塞率为9%,Medtronic和Vascutek分别为2.4%和2.5%。

核心结论

  • 髂支支架过度放大超过20%可能是EVAR后肢体闭塞的促进因素,应审慎选择放大比例。

研究设计与样本

  • 回顾性病例对照研究,纳入2个中心2007—2017年11年间连续接受EVAR的患者,共787例(男性702例;中位年龄78岁,范围53—94岁)。

主要发现

  • 50例发生主要结局(髂支闭塞),总体肢体闭塞率为6.35%。
  • 闭塞组中,支架过度放大超过自体血管直径10%为预测因素,50%的闭塞病例过度放大超过20%。
  • 闭塞组中髂外动脉锚定区为12/50例(24%),术后扭结为5/50例(10%),均更常见。
  • 随机选取的50例基线特征相似的对照组中,髂支支架过度放大在闭塞组显著大于对照组(P < 0.001),回归分析中仍显著。
  • 髂动脉扭曲与肢体闭塞无相关性;Cook支架的肢体闭塞率为9%,Medtronic和Vascutek分别为2.4%和2.5%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Limb occlusion is a potentially serious consequence of endovascular abdominal aortic aneurysm (EVAR). This case-control study identifies factors that predispose to limb occlusion. METHODS: A consecutive series of patients from 2 centers undergoing EVAR over an 11-year period 2007-2017 were identified retrospectively. Patient records were interrogated allowing collations of demographics, intraoperative and perioperative data and surveillance data. The preoperative computed tomography angiogram was analyzed to determine EVAR relevant anatomical data. The primary outcome was occlusion of the iliac limb of the implanted EVAR. Raw data are presented as percentages, with comparative data analyzed using Mann-Whitney U-test and binomial logistic regression. RESULTS: A total of 787 patients (702 males; median age 78 years, range 53-94 years old) were analyzed. Fifty patients reached the primary outcome, resulting in an overall limb occlusion rate of 6.35%. Factors predictive of limb occlusion were oversizing by >10% native vessel diameter, with oversizing of >20% in 50% of those that occluded. External iliac artery landing zone (12/50 limb occlusions) 24% and postoperative kinking (5/50 limb occlusions) 10% were also more common in those that occluded. Fifty randomly selected controls with similar baseline characteristics were studied. Oversizing of the iliac endograft was found to be significantly greater in the limb occlusion group compared to the controls (P < 0.001) which remained significant on regression analysis. There was no correlation with iliac tortuosity. The Cook stent graft had a 9% limb occlusion rate across sites. Medtronic and Vascutek endografts had 2.4% and 2.5% limb occlusion rates respectively. CONCLUSIONS: Oversizing of iliac limbs by >20% could be a contributing factor to limb occlusion after EVAR and judicious oversizing should be used.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Basra M, Hussain P, Li M, et al. Factors Related to Limb Occlusion After Endovascular Abdominal Aortic Aneurysm Repair (EVAR). Ann Vasc Surg. 2023. PMID: 37858668. doi:10.1016/j.avsg.2023.08.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。