文献速递主动脉疾病

近端瘤颈解剖对Ovation支架移植物行腹主动脉瘤腔内修复术后5年结局的影响

The Impact of Proximal Neck Anatomy on the 5-Year Outcomes Following Endovascular Aortic Aneurysm Repair With the Ovation Stent Graft.
PubMed 文献 · J Endovasc Ther · 2023-08-30

基于6项临床试验和欧洲上市后注册数据库的前瞻性汇总数据,分析1020例择期肾下型腹主动脉瘤腔内修复患者,探讨近端瘤颈解剖对Ovation支架术后5年结局的影响。宽瘤颈(≥28 mm)与较高的5年IA型内漏估测率相关(7.1% vs 4.3%;p=0.02),而短瘤颈、倒锥形和瘤颈成角与5年IA型内漏无显著关联。

要点

  • 宽近端瘤颈直径(≥28 mm)与Ovation支架术后5年IA型内漏估测率升高相关(7.1% vs 4.3%;p=0.02)。
  • 短瘤颈(<10 mm)、倒锥形(>10%)和瘤颈成角(>45°)与5年IA型内漏无显著关联。
  • 宽瘤颈还与较高的5年移植物移位估测率(3.8% vs 0.4%;p=0.03)和复合瘤颈相关不良结局估测率(16% vs 9.5%;p=0.002)相关。

核心结论

  • 宽近端瘤颈与Ovation支架移植物治疗后较高的5年IA型内漏率相关,而短瘤颈长度、倒锥形和瘤颈成角与较高的5年IA型内漏率无关。

研究设计与样本

  • 使用Ovation定制密封效果评估:证据回顾数据库的前瞻性收集数据,该数据库汇总了6项临床试验和欧洲上市后注册研究中2009年至2017年接受择期肾下型腹主动脉瘤腔内修复术的患者数据。
  • 共纳入1020例患者,其中短瘤颈60例、宽瘤颈直径113例、倒锥形279例、瘤颈成角>45°者99例。
  • 主要结局为IA型内漏,次要结局包括任何I/III型内漏、瘤囊扩张、动脉瘤相关再干预、全因和动脉瘤相关死亡,以及IA型内漏、移植物移位、AAA相关再干预、转换手术和动脉瘤破裂的复合终点。
  • 采用Kaplan-Meier分析和Cox比例风险模型估算30天和5年发生率,并评估单因素和风险校正后的差异。

主要发现

  • 宽近端瘤颈与有利瘤颈解剖相比,5年IA型内漏估测率更高(7.1% vs 4.3%;p=0.02)。
  • 短瘤颈长度与5年IA型内漏无关联(1.7% vs 4.3%;p=0.52),倒锥形无关联(3.2% vs 4.3%;p=0.99),瘤颈成角无关联(6.1% vs 4.3%;p=0.13)。
  • 宽瘤颈直径与有利解剖相比,5年移植物移位估测率更高(3.8% vs 0.4%;p=0.03),复合瘤颈相关不良结局终点估测率更高(16% vs 9.5%;p=0.002)。
  • 不良近端瘤颈解剖队列与有利解剖队列之间,瘤囊扩张、破裂以及总体和动脉瘤相关死亡率的估测值相似。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Hostile proximal neck anatomy has historically been associated with worse outcomes for endovascular aortic aneurysm repair (EVAR) of abdominal aortic aneurysms (AAA). We investigated the impact of proximal neck anatomy on the outcomes following EVAR with the Ovation abdominal stent graft (Endologix, Irving, Calif). METHODS: We used prospectively collected data from the Effectiveness of Custom Seal with Ovation: Review of the Evidence database, compromised of pooled data from 6 clinical trials and the European Post-Market Registry of patients undergoing elective infrarenal EVAR (2009-2017). We investigated the impact of short neck length (<10 mm), wide neck diameter (≥28 mm), reverse taper shape (>10%), and neck angulation (>45°) on the outcomes. The primary outcome was type IA endoleak. Secondary outcomes included any type I/III endoleak, sac expansion, aneurysm-related reinterventions, and all-cause and aneurysm-related mortality, and a combined endpoint of type IA endoleak, graft migration, AAA-related reintervention, conversion, and aneurysm rupture. We used Kaplan-Meier analysis and Cox proportional hazards models to estimate the 30 day and 5 year rates and assess univariate and risk-adjusted differences. RESULTS: Of the 1020 patients, 60 patients had a short neck, 113 had a wide neck diameter, 279 were reverse taper shaped, and 99 had neck angulation >45°. Wide proximal neck was associated with higher 5 year type IA endoleak estimates compared with favorable neck anatomy (7.1% vs 4.3%; p=0.02). No association with 5 year type IA endoleak was found for short neck length (1.7% vs 4.3%; p=0.52), reverse taper shape (3.2% vs 4.3%; p=0.99), or neck angulation (6.1% vs 4.3%; p=0.13). A wide neck diameter compared with favorable anatomy was also associated with higher 5 year estimates of graft migration (3.8% vs 0.4%; p=0.03) and the combined neck-related adverse outcome endpoint (16% vs 9.5%; p=0.002). The estimates of aneurysm sac expansion, rupture, and overall and aneurysm-related mortality were similar between the hostile proximal neck anatomy cohorts and favorable anatomy. CONCLUSION: Wide proximal neck is associated with higher 5 year type IA endoleak rates for patients treated with the Ovation stent graft. However, short neck length, reverse taper shape, and neck angulation are not associated with higher 5 year type IA endoleak rates.Clinical ImpactHostile proximal neck anatomy has historically been associated with worse outcomes for endovascular aortic aneurysm repair of abdominal aortic aneurysms. The Ovation stent graft platform uses a different proximal sealing method using a polymer inflatable ring, aiming to improve sealing between the graft and aortic wall. This study demonstrated that short, angulated, and reverse taper-shaped neck anatomy did not result in increased type IA endoleak estimates in patients treated with the Ovation stent graft platform. Potentially, the different sealing mechanisms played a role in mitigating the historically worse outcomes in patients with short, angulated, and reverse taper-shaped neck anatomy.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Varkevisser RRB, Patel PB, Swerdlow NJ, et al. The Impact of Proximal Neck Anatomy on the 5-Year Outcomes Following Endovascular Aortic Aneurysm Repair With the Ovation Stent Graft. J Endovasc Ther. 2023. PMID: 37646116. doi:10.1177/15266028231195771

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。