文献速递主动脉疾病颈动脉与弓上血管

三分支主动脉弓装置联合逆行左颈总动脉分支的早期结局:病例系列

Early Outcomes on Triple-Branch Arch Device With Retrograde Left Common Carotid Branch: A Case Series.
PubMed 文献 · J Endovasc Ther · 2023-08-28

本病例系列遵循PROCESS指南,纳入2022年10月27日至2023年2月28日连续8例择期使用定制三分支弓部装置(含逆行左颈总动脉分支)行腔内修复的患者,技术成功100%,30天无死亡及脑血管事件,5例(62.5%)发生主要并发症(3例入路相关需再干预,余为充血性心力衰竭)。

要点

  • 8例择期患者使用含逆行左颈总动脉分支的定制三分支弓部装置,技术成功100%。
  • 30天随访无死亡及脑血管事件,5例(62.5%)发生主要并发症。
  • 逆行分支经股动脉入路完成左颈总动脉血运重建,作者认为可降低脑血管并发症风险。

核心结论

  • 根据作者早期经验,逆行分支经股动脉入路便于左颈总动脉血运重建,降低脑血管并发症风险,但需更长随访评估装置安全性和有效性。

研究设计与样本

  • 病例系列,遵循PROCESS指南,连续纳入2022年10月27日至2023年2月28日接受定制三分支弓部装置(含逆行左颈总动脉分支,Cook Medical)腔内修复的8例择期患者。

主要发现

  • 8例患者中87.5%为男性,平均年龄72.3±27.0岁;5例(62.5%)既往因急性A型主动脉夹层行升主动脉修复。
  • 所有患者除1例因左喉返神经受压外均无症状;平均最大主动脉直径70.4±21.0 mm。
  • 技术成功100%;30天随访无死亡及脑血管事件。
  • 5例(62.5%)发生主要并发症,其中3例为入路相关需再干预,其余为充血性心力衰竭经药物治疗成功处理。
  • 随访(范围1-4个月)除1例发生继发性Ia型内漏外无事件。

临床怎么用

  • 作者认为逆行分支经股动脉入路可促进左颈总动脉血运重建并降低脑血管并发症风险,但需进一步分析以评估装置的安全性和有效性。

局限性

  • 原文报告随访范围1-4个月,并指出需更长随访进一步分析以评估装置安全性和有效性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Endovascular aortic arch repair using multibranch devices has been applied in patients considered at high risk for open repair. The aim of this case series was to report the early outcomes in patients managed with a new design 3 branch arch custom-made device, including a retrograde left common carotid artery (LCCA) branch. METHODS: The Preferred Reporting Of CaSe Series in Surgery (PROCESS) guidelines were followed. All consecutive patients undergoing endovascular repair of an aortic arch lesion with a custom-made triple-branch device, including a retrograde LCCA branch (Cook Medical, Bloomington, IN, USA), between October 27, 2022, and February 28, 2023, were included. The presence of an arch aneurysm (degenerative or post-dissection) with diameter ≥55 mm and high risk for a conventional open repair set the indication for treatment. The primary outcomes were technical success and mortality at 30 days. Early morbidity and reinterventions were considered as secondary outcomes. RESULTS: Eight elective patients (87.5% men, mean age 72.3±27.0 years) were included. Five of them (62.5%) had undergone a previous ascending aorta repair of an acute type A aortic dissection. All patients were asymptomatic, except one, with left recurrent laryngeal nerve compression. The mean maximum aortic diameter was 70.4±21.0 mm. Percutaneous femoral and axillary access was used in all cases except three in which a cut down for right carotid access was performed. Technical success was 100%. Femoral access to the LCCA and implantation of the bridging stent was performed without technical challenges. No death nor cerebrovascular event was recorded during the 30 day follow-up. Five patients (62.5%) presented major complications, 3 related to access needing reintervention and the remaining related to congestive heart failure (CHF), which were managed successfully with medical treatment. Follow-up (range 1-4 month) was uneventful, except for one patient who presented a secondary type Ia endoleak. CONCLUSIONS: According to our early experience, the presence of a retrograde branch facilitated the revascularization of the LCCA through femoral access, decreasing the risk of cerebrovascular morbidity. Further analyses with longer follow-up are needed to evaluate the safety and efficacy of the device.Clinical ImpactData arising mainly from the retrograde branch for the revascularization of the LSA are encouraging from a variety of devices. The premiminary experience with a triple-branched arch device, with a retrograde branche for the LSA but also for the LCCA, was associated with no 30 day mortality and 100% technical success.The device's design allowed swift catheterization and completion of the LCCA revascularization using femoral access exclusively.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Nana P, Houérou TL, Guihaire J, et al. Early Outcomes on Triple-Branch Arch Device With Retrograde Left Common Carotid Branch: A Case Series. J Endovasc Ther. 2023. PMID: 37635649. doi:10.1177/15266028231195758

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。