文献速递主动脉疾病内脏/肾动脉与血管畸形

重新衬垫桥接覆膜支架治疗开窗腔内动脉瘤修复术后IIIC型内漏的罕见原因

Relining of a Bridging Covered Stent to Treat a Rare Cause of Type IIIc Endoleak Following Fenestrated Endovascular Aneurysm Repair.
PubMed 文献 · J Endovasc Ther · 2023-06-07

本文报告一例开窗腔内动脉瘤修复术(FEVAR)后因左肾动脉(LRA)桥接支架经肠系膜上动脉(SMA)开窗误置导致的IIIC型内漏,通过穿刺原支架并沿LRA开窗重新衬垫新桥接覆膜支架成功治疗;术后造影及3个月随访CTA显示内漏完全消失且LRA通畅。

要点

  • FEVAR术中经错误开窗放置桥接支架是IIIC型内漏的罕见原因。
  • 经正确开窗穿刺并重新衬垫误置的桥接覆膜支架可成功治疗此类内漏。
  • 术后造影及3个月随访CTA显示内漏完全消失且左肾动脉通畅。

核心结论

  • FEVAR术中经错误开窗放置桥接支架是IIIC型内漏的罕见原因,某些情况下通过穿刺并沿目标血管正确开窗重新衬垫误置的桥接覆膜支架可成功治疗该内漏。

研究设计与样本

  • 技术报告,描述一例FEVAR术后IIIC型内漏的再次介入治疗。

主要发现

  • 患者FEVAR术后出现IIIC型内漏,原因是左肾动脉桥接球囊扩张覆膜支架(BECS)经肠系膜上动脉开窗误置并部署于SMA开窗外,BECS近端位于主体外,导致经开放LRA开窗的IIIC型内漏。
  • 再次介入采用再入导管进入原BECS管腔,经LRA开窗放置新BECS进行重新衬垫。
  • 术后造影及3个月随访CTA显示内漏完全消失且LRA通畅。

临床怎么用

  • 作者认为,某些情况下通过穿刺并沿目标血管正确开窗重新衬垫误置的桥接覆膜支架可成功治疗此类内漏,该技术或可帮助临床医生处理此或类似并发症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To present a rare cause of type III endoleak via the left renal artery (LRA) fenestration following fenestrated endovascular aneurysm repair (FEVAR) and to describe a successful reintervention for treating this endoleak. TECHNIQUE: The patient presented with a type IIIc endoleak following FEVAR, due to inadvertent placement of the LRA bridging balloon expandable covered stent (BECS) via the superior mesenteric artery (SMA) fenestration, but deployed outside the SMA fenestration. The proximal part of the BECS was positioned outside of the main body. This caused a type IIIc endoleak via the open LRA fenestration. Reintervention was performed by relining the LRA with a new BECS. First, access to the lumen of the previously placed BECS was gained using a re-entry catheter, followed by placement of a new BECS via the LRA fenestration. Completion angiography, and computerized tomography angiography (CTA) at 3 months follow-up showed total obliteration of the endoleak and patency of the LRA. CONCLUSION: Placement of a bridging stent via an incorrect fenestration during FEVAR is a rare cause of type III endoleak. In certain cases, successful treatment of such an endoleak could be achieved by perforation and relining of the misplaced BECS via the correct fenestration of the target vessel.Clinical ImpactTo our best knowledge, a type IIIc endoleak following fenestrated endovascular aneurysm repair, due to placement of a bridging covered stent through an incorrect fenestration and deployed short of the fenestration, has not been described before. Reintervention was performed with perforation of the previously placed covered stent and relining using a new bridging covered stent. The technique presented here was successful for treating the endoleak in this case and could help guide clinicians when dealing with this or similar complications.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Huistra EWM, Tielliu IFJ, Kater GM, et al. Relining of a Bridging Covered Stent to Treat a Rare Cause of Type IIIc Endoleak Following Fenestrated Endovascular Aneurysm Repair. J Endovasc Ther. 2023. PMID: 37287253. doi:10.1177/15266028231179426

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。