腹主动脉瘤患者临床异质性识别及新亚型预测模型构建:一项无监督机器学习研究
本研究纳入266例接受EVAR的腹主动脉瘤患者,用无监督机器学习算法按临床特征聚类,分析两簇的手术与术后结果以验证准确性,并用二元逻辑回归建立预测模型与列线图,其AUC为0.933(95%CI 0.902-0.963),C-index为0.927。
要点
- 无监督机器学习可依据临床特征将腹主动脉瘤患者有效聚类。
- 第1簇患者较第2簇更易发生肺炎、慢性阻塞性肺疾病和脑血管病。
- 基于BMI、颈角及双侧髂总动脉直径与角度构建的列线图AUC为0.933。
核心结论
- 无监督机器学习能有效合理地对异质性腹主动脉瘤患者队列进行分类,术后变量分析验证了其准确性,所建新亚型预测模型可提高腹主动脉瘤患者管理质量。
研究设计与样本
- 纳入266例接受EVAR的腹主动脉瘤患者,采用无监督机器学习算法按相似临床特征对受试者聚类,分析两簇的手术与术后结果以验证算法准确性,最后用二元逻辑回归分析建立预测模型。
主要发现
- 第1簇患者较第2簇更年长、BMI更高,且更易发生肺炎、慢性阻塞性肺疾病和脑血管病。
- 第1簇患者的瘤径、颈角、双侧髂总动脉直径与角度及髂动脉瘤发生率均显著高于第2簇。
- 第1簇手术时间更长、重症监护病房和住院时间更长、医疗费用更高,再干预发生率更高。
- 基于BMI、颈角、左髂总动脉(LCIA)直径与角度、右髂总动脉(RCIA)直径与角度建立列线图。
- 列线图经受试者工作特征曲线分析评估,曲线下面积为0.933(95%CI 0.902-0.963),C-index为0.927。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Abdominal aortic aneurysm (AAA) is one of the most common diseases in vascular surgery. Endovascular aneurysm repair (EVAR) can effectively treat AAA. It is essential to accurately classify patients with AAA who need EVAR. METHODS: We enrolled 266 patients with AAA who underwent EVAR. Unsupervised machine learning algorithms (UMLAs) were used to cluster subjects according to similar clinical characteristics. To verify UMLA's accuracy, the operative and postoperative results of the 2 clusters were analyzed. Finally, a prediction model was developed using binary logistic regression analysis. RESULTS: UMLAs could correctly classify patients based on their clinical characteristics. Patients in Cluster 1 were older, had a higher BMI, and were more likely than patients in Cluster 2 to develop pneumonia, chronic obstructive pulmonary disease, and cerebrovascular disease. The aneurysm diameter, neck angulation, diameter and angulation of bilateral common iliac arteries, and incidence of iliac artery aneurysm were significantly higher in cluster 1 patients than in cluster 2. Cluster 1 had a longer operative time, a longer length of stay in the intensive care unit and hospital, a higher medical expense, and a higher incidence of reintervention. A nomogram was established based on the BMI, neck angulation, left common iliac artery (LCIA) diameter and angulation, and right common iliac artery (RCIA) diameter and angulation. The nomogram was evaluated using receiver operating characteristic curve analysis, with an area under the curve of 0.933 (95% confidence interval, 0.902-0.963) and a C-index of 0.927. CONCLUSIONS: Our findings demonstrate that UMLAs can be used to rationally classify a heterogeneous cohort of patients with AAA effectively, and the analysis of postoperative variables also verified the accuracy of UMLAs. We established a prediction model for new subtypes of AAA, which can improve the quality of management of patients with AAA.
引用
- Zhang L, Wei J, Wei J, et al. Identification of Clinical Heterogeneity and Construction of Prediction Models for Novel Subtypes in Patients with Abdominal Aortic Aneurysm: An Unsupervised Machine Learning Study. Ann Vasc Surg. 2023. PMID: 37380047. doi:10.1016/j.avsg.2023.06.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。