文献速递主动脉疾病

针对非复杂性B型主动脉夹层行2区锚定胸主动脉腔内修复并测量假腔腔内压力

Thoracic Endovascular Aortic Repair on Zone 2 Landing for Uncomplicated Type B Aortic Dissection with Measurement of Intra-False Lumen Pressure.
PubMed 文献 · Ann Vasc Surg · 2023-06-23

回顾15例非复杂性B型主动脉夹层患者行2区胸主动脉腔内修复(TEVAR),术中测量假腔腔内压力(IFLP),评估中期主动脉重塑与假腔血栓化。封堵主要破口后各水平收缩期压差显著下降,远端弓部真腔扩大82%、假腔完全血栓化100%,随访41个月无主动脉相关死亡。

要点

  • 2区TEVAR治疗非复杂性B型主动脉夹层,13例(87%)通过覆膜支架开窗保留左锁骨下动脉。
  • 封堵主要破口后各水平收缩期压差较术前显著下降,远端弓部由-5.2±9.6降至-22.2±10.8 mm Hg。
  • 12个月时远端弓部真腔扩大82%、假腔完全血栓化100%,向远端逐级降低(L2真腔扩大50%、假腔完全血栓化0%)。

核心结论

  • 2区TEVAR治疗非复杂性B型主动脉夹层可能预防TEVAR相关并发症。
  • 测量假腔腔内压力可能成为评估主动脉重塑程度的新预测标志物。

研究设计与样本

  • 回顾性分析15例(男性9例,平均年龄57岁)因非复杂性B型主动脉夹层接受2区TEVAR的患者。
  • 在封堵主要破口前后测量收缩期压差(定义为全身压力与假腔腔内压力之差)。
  • TEVAR后12个月在主动脉5个不同水平评估主动脉重塑及假腔血栓闭塞情况。

主要发现

  • 发病至TEVAR的中位时间为34天,13例(87%)通过覆膜支架开窗保留左锁骨下动脉。
  • 1例(6%)发生短暂性脑梗死,无严重TEVAR相关并发症。
  • 封堵破口后各水平收缩期压差(mm Hg)较术前显著下降:远端弓部-22.2±10.8 vs -5.2±9.6,Th8 -20.1±12.4 vs -6.9±7.2,Th10 -14.3±14.6 vs -4.7±7.5,Th12 -14.4±14.5 vs -4.9±7.8,L2 -14.5±14.2 vs -3.4±6.9。
  • 12个月时真腔扩大的主动脉重塑比例:远端弓部82%,Th8 80%,Th10 54%,Th12 45%,L2 50%。
  • 12个月时假腔完全血栓化比例:远端弓部100%,Th8 100%,Th10 67%,Th12 11%,L2 0%。

临床怎么用

  • 原文结论指出,2区TEVAR治疗非复杂性B型主动脉夹层可能预防TEVAR相关并发症。
  • 原文结论指出,测量假腔腔内压力可能成为评估主动脉重塑程度的新预测标志物。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to evaluate the midterm results of zone 2 thoracic endovascular aortic repair (TEVAR) for uncomplicated type B aortic dissection (TBAD) by measuring the intra-false lumen pressure (IFLP) during TEVAR. METHODS: Fifteen patients (9 men; mean age, 57 years) who underwent zone 2 TEVAR for uncomplicated TBAD were reviewed. Delta systolic pressure (defined as the difference between systemic pressure and IFLP) was measured before and after primary entry closure, and aortic remodeling and thrombo-occlusion of the false lumen (FL) were evaluated 12 months after TEVAR at 5 different levels of the aorta. RESULTS: Median duration from onset to TEVAR was 34 days. The left subclavian artery was preserved in 13 patients (87%) by using stent graft fenestration. Although 1 patient (6%) had a transient cerebral infarction, there were no severe TEVAR-related complications. Entry closure significantly reduced delta systolic pressure (mm Hg) compared to preoperative pressure at all levels (distal arch: -22.2 ± 10.8 vs. -5.2 ± 9.6; Th8: -20.1 ± 12.4 vs. -6.9 ± 7.2; Th10: -14.3 ± 14.6 vs. -4.7 ± 7.5; Th12: -14.4 ± 14.5 vs. -4.9 ± 7.8; L2: -14.5 ± 14.2 vs. -3.4 ± 6.9). The percentages of aortic remodeling with expansion of the true lumen (distal arch: 82%; Th8: 80%; Th10: 54%; Th12: 45%; L2: 50%) and complete false lumen thrombosis (distal arch: 100%; Th8: 100%; Th10: 67%; Th12: 11%; L2: 0%) were approximately consistent with the change in delta systolic pressure. During a follow-up of 41 months, distal stent-induced new entry occurred in 2 patients (13%) requiring secondary intervention; however, there were no cases of FL enlargement or aorta-related mortality. CONCLUSIONS: Zone 2 TEVAR for uncomplicated TBAD may prevent TEVAR-related complications. Measuring IFLP could be a new predictive marker for assessing the extent of aortic remodeling.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Miura S, Kurimoto Y, Maruyama R, et al. Thoracic Endovascular Aortic Repair on Zone 2 Landing for Uncomplicated Type B Aortic Dissection with Measurement of Intra-False Lumen Pressure. Ann Vasc Surg. 2023. PMID: 37355017. doi:10.1016/j.avsg.2023.06.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。