既往主动脉修复术后采用髂动脉分支装置行髂内动脉挽救的结果
这项多中心研究评估既往开放主动脉修复(OAR)或血管腔内主动脉修复(EVAR)后植入髂动脉分支装置(IBD)挽救髂内动脉的结果,共纳入94例患者、104个装置。两组技术成功率均为100%,既往OAR组3年分支不稳定免除率及分支原发通畅率均低于EVAR组。
要点
- 既往EVAR后植入IBD 73个、既往OAR后31个,两组技术成功率均为100%。
- 3年分支不稳定免除率:既往EVAR后90.1% vs 既往OAR后85.4%(P = .05)。
- 3年分支原发通畅率既往OAR后89.8% vs 既往EVAR后94.9%(P = .05)。
核心结论
- 既往OAR或EVAR后采用IBD行血管腔内治疗在3年内安全有效。
- 随访期间分支不稳定免除率在既往OAR患者中低于EVAR患者。
研究设计与样本
- 多中心研究,纳入七家中心既往OAR或EVAR后连续接受IBD植入的全部患者。
- 共94例患者(82例男性),其中10例接受双侧IBD植入,最终分析共104个装置。
- 按原修复类型分为两组:既往EVAR后73个装置,既往OAR后31个装置。
主要发现
- 治疗指征为内漏1b型、髂动脉瘤进展性退变或远端吻合口旁主动脉瘤。
- 两组技术成功率均为100%。
- 3年分支不稳定免除率:既往EVAR后90.1% vs 既往OAR后85.4%(P = .05)。
- 3年分支原发通畅率:既往OAR后89.8% vs 既往EVAR后94.9%(P = .05),OAR组显著低于EVAR组。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The aim of this multicentric study was to assess the "REsults of iliac branch deviceS for hypogastriC salvage after previoUs aortic rEpair (RESCUE)." METHODS: All consecutive patients who underwent implantation of iliac branch devices (IBDs) after previous open aortic repair (OAR) or endovascular aortic repair (EVAR) at seven centers were captured. The study cohort was divided into two groups according to the type of repair originally performed. Early outcomes included immediate technical success and perioperative adverse events. Late outcomes included survival, side branch (SB) primary patency, SB instability, and new onset buttock claudication. RESULTS: A total of 94 patients (82 male) were included in the study, 10 of them received bilateral implantation of IBDs. This resulted in a total of 104 devices included in the final analysis. Indication for treatment were endoleak 1b or progressive iliac aneurysmal degeneration or distal para-anastomotic aortic aneurysms; 73 were implanted after previous EVAR and 31 after previous OAR. Technical success was 100% in both groups. The 3-year rate of freedom from SB instability was 90.1% after previous EVAR and 85.4% after previous OAR, respectively (P = .05). The 3-year estimates of SB primary patency were significantly lower in patients who had received OAR as compared with those that had received EVAR (89.8% vs 94.9%; P = .05). CONCLUSIONS: Endovascular treatment with IBDs following previous OAR or EVAR is safe and effective up to 3 years. Freedom from SB instability during follow-up was lower in patients who had previously undergone OAR than EVAR.
引用
- Mastrorilli D, Mezzetto L, Antonello M, et al. Results of iliac branch devices for hypogastric salvage after previous aortic repair. J Vasc Surg. 2023. PMID: 37343732. doi:10.1016/j.jvs.2023.06.008
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。