文献速递主动脉疾病

破裂性腹主动脉瘤患者中基于移植物特定使用说明评估血管内动脉瘤修复适用性

Assessing Endovascular Aneurysm Repair Suitability According to Graft-Specific Instructions for Use in Patients With a Ruptured Abdominal Aortic Aneurysm.
PubMed 文献 · J Endovasc Ther · 2023-04-25

该回顾性研究利用术前CTA评估2家荷兰医院2014年1月至2019年12月收治的128例破裂性腹主动脉瘤患者的主动脉形态是否符合所用支架移植物的使用说明(IFU)。结果显示仅24%患者解剖符合IFU,不符合者中90%为瘤颈解剖不合适、64%为瘤颈长度不足;围术期死亡率27%,开放修复与EVAR间无差异。作者认为IFU外解剖是否等同于急诊EVAR不适用仍有争议,需进一步研究。

要点

  • 128例破裂性腹主动脉瘤患者中仅31例(24%)解剖符合EVAR的IFU。
  • IFU外解剖者中90%(87/97)瘤颈解剖不合适,64%(62/97)瘤颈长度不足。
  • 围术期死亡率27%(34/128),开放修复与EVAR间无差异(25/94 vs 9/34;p=0.989)。

核心结论

  • 本系列中多数破裂性腹主动脉瘤患者的主动脉解剖不符合EVAR的IFU,主要因瘤颈长度不足。
  • IFU外解剖在急诊情况下是否等同于EVAR不适用仍有争议,需进一步研究。

研究设计与样本

  • 回顾性评估2家荷兰医院2014年1月至2019年12月因破裂性腹主动脉瘤行手术修复患者的术前CTA主动脉形态。
  • 使用三维和中心腔线重建,根据所用支架移植系统的IFU定义解剖适用性。
  • 共纳入128例患者,其中男性112例(88%),平均年龄74.1岁(SD=7.6)。

主要发现

  • 解剖符合EVAR的IFU者31例(24%)。
  • 94例(73%)接受开放手术修复,34例(27%)接受EVAR。
  • 开放手术组中15例(16%)解剖符合IFU,EVAR组中16例(47%)解剖符合IFU。
  • IFU外解剖者中,90%(87/97)瘤颈解剖不合适,64%(62/97)瘤颈长度不足;35例远端髂动脉着陆区不合适。
  • 围术期死亡率为27%(34/128),开放手术与EVAR间无差异(25/94 vs 9/34;p=0.989)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of the study is to ascertain endovascular aneurysm repair (EVAR) suitability in relation to stent-graft-specific instructions for use (IFU) in patients with a ruptured abdominal aortic aneurysm (RAAA). MATERIALS AND METHODS: Using the preoperative computed tomography angiography (CTA), the aortic morphology of patients undergoing surgical repair of a RAAA in 2 Dutch hospitals between January 2014 and December 2019 was retrospectively assessed. Three-dimensional and central luminal line reconstructions were used. Anatomical suitability was defined according to the IFU of the stent graft system used. RESULTS: Of 128 included patients, 112 (88%) were men and the mean age was 74.1 (SD=7.6) years. Anatomy within IFU for EVAR was present in 31 patients (24%). Overall, 94 patients (73%) were treated with open surgical repair (OSR) and 34 patients (27%) were treated with EVAR. Anatomy within IFU was present in 15 OSR patients (16%) and 16 EVAR patients (47%). In patients with anatomy outside of IFU, 90% (87/97) had unsuitable neck anatomy and 64% (62/97) had insufficient neck length. An unsuitable distal iliac landing zone was observed in 35 patients. Perioperative mortality was 27% (34/128), with no difference between OSR and EVAR (25/94 vs 9/34; p=0.989). CONCLUSION: Most RAAA patients in this series did not have aortic anatomy within IFU for EVAR, mainly due to insufficient neck length. However, whether anatomy outside of IFU equates to unsuitability for EVAR in an emergency setting remains a matter of debate and warrants further research. CLINICAL IMPACT: The treatment of a ruptured abdominal aortic aneurysm can consist of endovascular repair or open repair. Retrospective anatomical assessment shows that most patients do not have anatomy inside the instructions for use for endovascular aneurysm repair, mainly due to insufficient neck length. Whether anatomy outside the instructions for use equates unsuitability for endovascular aneurysm repair remains a matter of debate.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Gjosha B, Jan Boer G, Fioole B, et al. Assessing Endovascular Aneurysm Repair Suitability According to Graft-Specific Instructions for Use in Patients With a Ruptured Abdominal Aortic Aneurysm. J Endovasc Ther. 2023. PMID: 37096758. doi:10.1177/15266028231169180

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。