文献速递主动脉疾病外周动脉疾病

医师改良Y型髂动脉分支装置(PMYIBD)在腹主动脉瘤腔内修复术中保留髂内动脉的临床研究

Clinical Study of a Physician Modified Y-Type Iliac Branch Device (PMYIBD) in the Endovascular Repair of Abdominal Aortic Aneurysms to Preserve the Internal Iliac Artery.
PubMed 文献 · J Endovasc Ther · 2023-04-17

2018年9月至2022年4月,本科收治24例腹主动脉瘤或夹层动脉瘤累及髂总动脉患者,术中制备医师改良Y型髂动脉分支装置(PMYIBD)行腔内修复并重建髂内动脉。全部手术成功,平均随访(27.1±13.5)个月,无瘤腔扩大、内漏、支架移位或死亡。作者认为该技术安全有效,远期效果需进一步随访。

要点

  • 24例腹主动脉瘤或夹层动脉瘤患者术中制备PMYIBD行腔内修复,全部手术成功。
  • 共重建24条髂内动脉,平均随访(27.1±13.5)个月无瘤腔扩大、内漏、支架移位及死亡。
  • 作者认为PMYIBD为累及髂内动脉的复杂解剖主动脉疾病提供简单有效的全腔内修复方法。

核心结论

  • 医师改良Y型髂动脉分支装置技术对累及髂内动脉的主动脉疾病安全有效,尤其适用于复杂解剖条件。

研究设计与样本

  • 单臂临床研究,2018年9月至2022年4月在本院收治24例腹主动脉瘤或夹层动脉瘤累及髂总动脉患者,其中真性动脉瘤19例、夹层动脉瘤5例,平均年龄(65.3±7.6)岁。
  • 所有患者术前均行增强CT评估,结合术中造影在手术过程中制备Y型支架移植物行腹主动脉瘤腔内修复。

主要发现

  • 全部手术成功完成,平均手术时间(224.8±44.1)分钟,共重建24条髂内动脉。
  • 平均随访时间(27.1±13.5)个月,随访期间全部患者无瘤腔扩大、无内漏、无支架移位、无死亡。

临床怎么用

  • 作者认为在合适商业支架不可获得时,PMYIBD是临床医生的良好选择。
  • 作者认为保留髂内动脉在EVAR中有意义,PMYIBD为累及髂内动脉的主动脉疾病全腔内修复提供了简单有效的方法。

局限性

  • 作者指出远期效果需要进一步随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To report the method and curative effect of using a physician modified Y-type iliac branch device (PMYIBD) to preserve the internal iliac artery during the endovascular repair of abdominal aortic aneurysms. METHODS: From September 2018 to April 2022, 24 patients with abdominal aortic aneurysms or dissecting aneurysms, including 19 true aneurysms and 5 dissecting aneurysms involving the common iliac artery were treated in our department. The average age was (65.3 ± 7.6) years. All patients underwent preoperative evaluation by enhanced computed tomography. Combined with intraoperative angiography, a Y-type stent graft was prepared during surgery to perform endovascular repair of abdominal aortic aneurysms. RESULTS: All operations were successfully completed. The average operative duration was (224.8 ± 44.1) minutes. A total of 24 internal iliac arteries were reconstructed. The average follow-up time was (27.1 ± 13.5) months. During the follow-up, there was no expansion of aneurysm cavity, no endoleak or stent displacement, and no death occurred in all patients. DISCUSSION: The physician-modified Y-type iliac branched device (PMYIBD) provides an effective method for full-cavity repair. It has a wide range of indications and convenience. According to follow-up results, the early and mid-term had good curative effects; however, the long-term effects require further follow-up. CONCLUSION: The modified Y-type IBD technique is safe and effective for aortic diseases involving internal iliac artery especially with complex anatomy. CLINICAL IMPACT: It is meaningful to preserve the IIA during EVAR. The use of PMYIBD provides a simple and effective method for the total endovascular repair of aortic diseases involving the IIA. Several advantages such as minimal trauma, low mortality, low complication rates and perfect short- and medium-term effects emerge in clinical practice. PMYIBDs are good choices for clinicians before suitable commercial stents are available in markets.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Zhao Z, Jin Y, Fu D, et al. Clinical Study of a Physician Modified Y-Type Iliac Branch Device (PMYIBD) in the Endovascular Repair of Abdominal Aortic Aneurysms to Preserve the Internal Iliac Artery. J Endovasc Ther. 2023. PMID: 37066784. doi:10.1177/15266028231165185

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。