文献速递主动脉疾病

复杂血管腔内主动脉修复术后预防性自动容量导向引流方案下脊髓引流相关并发症

Spinal drain-related complications after complex endovascular aortic repair using a prophylactic automated volume-directed drainage protocol.
PubMed 文献 · J Vasc Surg · 2023-04-25

该回顾性单中心研究纳入2014年1月至2020年12月期间接受复杂血管腔内主动脉修复(cEVAR)并放置脑脊液引流(CSFD)的147例患者,采用自动容量导向引流方案。18例(12.2%)发生CSFD相关并发症,其中3例(2%)为致残性;19例(13%)发生脊髓缺血(SCI),6例(4%)残留症状且判定为致残。SCI患者中引流相关并发症发生率(31.6%)高于无SCI患者(9.4%,P=0.014)。作者认为对SCI高风险患者选择性使用预防性自动容量导向CSFD与高并发症发生率相关,应谨慎使用。

要点

  • 147例cEVAR患者预防性放置CSFD,18例(12.2%)发生CSFD相关并发症,3例(2%)为致残性。
  • 19例(13%)发生SCI,其中13例(68%)症状完全逆转,6例(4%)残留症状且判定为致残。
  • SCI患者引流相关并发症发生率31.6%,高于无SCI患者的9.4%(P=0.014)。

核心结论

  • 对SCI高风险患者选择性使用预防性自动容量导向CSFD与高并发症发生率相关,应谨慎使用。
  • 发生SCI者中,增加CSFD引流量常可实现症状逆转,但代价是出血并发症增多。

研究设计与样本

  • 回顾性单中心研究,纳入2014年1月至2020年12月期间在某三级血管中心接受cEVAR并放置CSFD的全部患者。
  • 共识别448例cEVAR患者,其中147例(32.8%)接受预防性CSFD;平均年龄69岁,男性占63%。
  • 最常见病理为胸腹主动脉瘤(61%),最常见术式为分支型EVAR(55.1%)。
  • 所有引流均使用自动引流系统(LiquoGuard7;Möller Medical GmbH)进行容量导向引流。
  • 引流并发症按改良Rankin量表分为致残性与非致残性;主要终点为任何CSFD相关并发症。

主要发现

  • 18例(12.2%)发生CSFD相关并发症,其中3例(2%)为致残性。
  • 19例(13%)发生SCI:12例(8.4%)轻截瘫,5例(3.4%)截瘫,2例(1.4%)感觉异常。
  • SCI患者中13例(68%)症状完全逆转,6例(4%)残留症状且判定为致残。
  • SCI患者引流相关并发症发生率31.6%,高于无SCI患者的9.4%(P=0.014)。
  • 无SCI患者中仅2例(1.6%)发生致残性引流相关并发症。

临床怎么用

  • 作者认为对SCI高风险患者选择性使用预防性自动容量导向CSFD应谨慎使用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: A common measure to lower the risk for spinal cord ischemia (SCI) during complex endovascular aortic repair (cEVAR) is prophylactic cerebrospinal fluid drainage (CSFD). This method has caused controversy because of drain-related complications. Spinal drains are usually pressure directed. The objective of this study was to evaluate the risk of CSFD-related complications and SCI within the context of an automated volume-directed drain protocol. METHODS: This is a retrospective, single-center study of all cEVARs with CSFD at a tertiary vascular center between January 2014 and December 2020. Demographics, complications, and spinal drain data were recorded. All drainages were volume based using an automatic drainage system (LiquoGuard7; Möller Medical GmbH). Spinal drain complications were categorized as disabling and nondisabling according to the modified Rankin scale. The primary end point was any CSFD-related complication. RESULTS: A total of 448 cEVAR patients were identified, of whom 147 (32.8%) had prophylactic CSFD. The mean age was 69 years (63% male). The most common pathology (61%) was thoracoabdominal aortic aneurysm, and the most common procedure was branched EVAR (55.1%). Eighteen (12.2%) patients developed a CSFD-related complication, whereof three (2%) were disabling. Nineteen (13%) patients developed SCI: 12 (8.4%) paraparetic, 5 (3.4%) paraplegic, and 2 (1.4%) paresthesias. Of these, 13 (68%) had full reversal of symptoms, whereas 6 patients (4%) had residual symptoms and were deemed disabling. Drain-related complications were more common in patients with SCI (31.6%) compared with those without (9.4%, P = .014). In the latter group, only two patients (1.6%) developed a disabling drain-related complication. CONCLUSIONS: Selective use of prophylactic, automated volume-directed CSFD in patients at high risk for SCI was associated with a high incidence of complications and should be used with caution. Among those developing SCI, reversal was achieved frequently with increased CSFD volume, but at the price of more bleeding complications.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Jónsson GG, Mani K, Mosavi F, et al. Spinal drain-related complications after complex endovascular aortic repair using a prophylactic automated volume-directed drainage protocol. J Vasc Surg. 2023. PMID: 37105333. doi:10.1016/j.jvs.2023.03.505

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。