本研究回顾性分析了2017年1月至2020年2月96例接受三种商用髂分支装置(IBD)治疗主髂动脉或髂动脉瘤的患者,主要终点为24个月时IBD不稳定率。三种IBD的24个月分支不稳定率相似(Jotec 1/24(4.1%)、Gore 1/12(8.3%)、Cook 6/47(12.7%),P=0.502),无分支闭塞及分支相关内漏的统计学差异;Jotec组主动脉瘤囊最大直径较基线显著减小,仅与Gore组相比有差异。结论认为IBD是保留髂内动脉通畅的安全方法,IBD不稳定率低。

要点

  • 24个月分支不稳定率:Jotec 1/24(4.1%)、Gore 1/12(8.3%)、Cook 6/47(12.7%),P=0.502。
  • Jotec组主动脉瘤囊最大直径较基线显著减小,仅与Gore组相比有差异。
  • 24个月无任何分支不稳定的Kaplan-Meier估计值:Jotec 95.8%、Gore 91.6%、Cook 86.8%。

核心结论

  • 使用IBD是治疗主髂动脉或髂动脉瘤时保留髂内动脉通畅的安全方法,IBD不稳定率低。

研究设计与样本

  • 回顾性研究,纳入2017年1月至2020年2月共96例患者,评估三种商用IBD(Zenith Branch Iliac Endovascular Graft、Gore Excluder Iliac Branch System、E-liac Stent Graft System)的安全性和有效性。
  • 主要终点为24个月时IBD不稳定率;次要终点包括任何内漏发生、臀部跛行、IBD相关再干预及全因死亡率、术后急性肾损伤、主动脉瘤囊最大直径较基线变化。

主要发现

  • 24个月分支不稳定率三组相似:Jotec 1/24(4.1%)、Gore 1/12(8.3%)、Cook 6/47(12.7%),P=0.502。
  • 分支闭塞和分支相关内漏无统计学差异。
  • Jotec组主动脉瘤囊最大直径较基线显著减小,仅与Gore组相比有差异。
  • 任何内漏发生、再干预及全因死亡率无其他差异。
  • 24个月无任何分支不稳定的Kaplan-Meier估计值:Jotec 95.8%、Gore 91.6%、Cook 86.8%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of study was to assess the safety and effectiveness of 3 different commercial iliac branch devices (IBDs): the Zenith Branch Iliac Endovascular Graft; the Gore Excluder Iliac Branch System and the E-liac Stent Graft System for the treatment of aorto-iliac or iliac aneurysms. METHODS: From January 2017 to February 2020, a retrospective reviewed was conducted on a total of 96 patients. Primary endpoint was IBD instability rate at 24 months. Secondary endpoints included onset of any endoleaks, buttock claudication, IBD-related reintervention and all-death rates, postoperative acute kidney, and changes in maximum diameter from baseline of the aortic aneurysmal sac. RESULTS: At 24 months, the branch instability rate was similar among the 3 IBDs employed [Jotec 1/24 (4.1%), Gore 1/12 (8.3%), Cook 6/47 (12.7%), P-value = 0.502]. As well, no statistical difference in terms of branch occlusion and branch-related endoleaks was observed. The Jotec group showed a significant decrease in maximum diameter from the baseline of the aortic aneurysmal sac when compared to the Gore group alone. No other differences were found relevant to the onset of any endoleaks, reinterventions, and all-death rates. At 24 months, the Kaplan-Meier estimate of survival freedom from any branch instability was 95.8%, 91.6%, and 86.8% for Jotec, Gore and Cook groups, respectively. CONCLUSIONS: The use of IBDs represents a safe method for preserving patency of the IIA during treatment of aorto-iliac or iliac aneurysms providing a low rate of IBD instability.