比较慢速输注序列K空间填充磁共振血管造影与计算机断层血管造影检测Adamkiewicz动脉
本研究纳入63例胸主动脉或胸腹主动脉疾病患者(30例主动脉夹层,33例主动脉瘤),均行CTA和慢速输注序列K空间填充钆增强MRA检测Adamkiewicz动脉(AKA)。MRA在全部患者中的AKA检出率高于CTA(92.1% vs 71.4%,P=0.003),在主动脉夹层患者(93.3% vs 66.7%,P=0.01)及动脉瘤患者中AKA起源于非动脉瘤段者(100% vs 81.8%,P=0.03)也更高。开放或腔内修复术后脊髓缺血发生率为1.8%。
要点
- 慢速输注序列K空间填充MRA在全部63例患者中AKA检出率92.1%,高于CTA的71.4%(P=0.003)。
- 主动脉夹层30例中MRA检出率93.3%,高于CTA的66.7%(P=0.01)。
- 动脉瘤患者中AKA起源于非动脉瘤段22例,MRA检出率100%,高于CTA的81.8%(P=0.03)。
核心结论
- 尽管慢速输注MRA检查时间更长、成像技术较CTA更复杂,但其高空间分辨率可能更适于在各类胸主动脉和胸腹主动脉手术前检测AKA。
研究设计与样本
- 共纳入63例胸主动脉或胸腹主动脉疾病患者(30例主动脉夹层,33例主动脉瘤),均行CTA和慢速输注序列K空间填充钆增强MRA检测AKA。
主要发现
- 全部63例患者中,MRA与CTA的AKA检出率分别为92.1%和71.4%(P=0.003)。
- 30例主动脉夹层患者中,MRA与CTA的AKA检出率分别为93.3%和66.7%(P=0.01)。
- 7例AKA起源于假腔的主动脉夹层患者中,MRA与CTA的AKA检出率分别为100%和0%。
- 22例AKA起源于非动脉瘤段的动脉瘤患者中,MRA与CTA的AKA检出率分别为100%和81.8%(P=0.03)。
- 开放或腔内修复术后脊髓缺血发生率为1.8%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Radiographic detection of the Adamkiewicz artery (AKA) before aortic surgery helps to avoid spinal cord ischemia (SCI). We applied magnetic resonance angiography (MRA) using gadolinium enhancement (Gd-MRA) by means of the slow-infusion method with sequential k-space filling and compared AKA detectability with that of computed tomography angiography (CTA). METHODS: A total of 63 patients with thoracic or thoracoabdominal aortic disease (30 with aortic dissection [AD] and 33 with aortic aneurysm) who underwent both CTA and Gd-MRA to detect AKA were evaluated. The detectability of the AKA using Gd-MRA and CTA were compared among all patients and subgroups based on anatomical features. RESULTS: The detection rates of the AKAs using Gd-MRA and CTA were higher in all 63 patients (92.1% vs. 71.4%, P = 0.003). In AD cases, the detection rates using Gd-MRA and CTA were higher in all 30 patients (93.3% vs. 66.7%, P = 0.01) as well as in 7 patients whose AKA originated from false lumens (100% vs. 0%). In aneurysm cases, the detection rates using Gd-MRA and CTA were higher in 22 patients whose AKA originated from the nonaneurysmal parts (100% vs. 81.8%, P = 0.03). In clinical, SCI was observed in 1.8% of cases after open or endovascular repair. CONCLUSIONS: Despite the longer examination time and more complicated imaging techniques compared to those of CTA, the high spatial resolution of slow-infusion MRA may be preferable for detecting AKA before performing various thoracic and thoracoabdominal aortic surgeries.
引用
- Mizushima S, Mine T, Abe M, et al. Comparison of Slow-Infusion Magnetic Resonance Angiography with Sequential K-Space Filling and Computed Tomography Angiography to Detect the Adamkiewicz Artery. Ann Vasc Surg. 2023. PMID: 36868460. doi:10.1016/j.avsg.2023.02.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。