文献速递主动脉疾病

三维打印引导开窗/分支胸主动脉腔内修复术行三支主动脉弓分支重建的疗效分析

Three-Dimensional Printing to Guide Fenestrated/Branched TEVAR in Triple Aortic Arch Branch Reconstruction With a Curative Effect Analysis.
PubMed 文献 · J Endovasc Ther · 2023-03-21

单中心回顾性总结2018年2月至2022年4月44例累及三支主动脉弓分支的弓部动脉瘤或夹层患者,在三维打印模型引导下用医师改良支架行开窗/分支胸主动脉腔内修复术,132支分支全部重建成功,无中转开放手术,30天内无死亡,术后神经系统并发症1例(2.3%)、逆行A型夹层1例(2.3%)。

要点

  • 三维打印模型将影像数据转为实体模型,用于引导开窗定位,提高开窗位置准确性。
  • 44例患者132支主动脉弓分支全部重建成功,无中转开放手术,30天内无死亡。
  • 术后神经系统并发症1例(2.3%),逆行A型夹层1例(2.3%)。

核心结论

  • 作者认为,与传统手术相比,三维打印引导下的三支主动脉弓分支重建是一种微创治疗方法,具有定位准确、术后恢复快、并发症少以及短期至中期疗效可靠的优点。
  • 作者指出,作为可重复的研究,其结果可为不同病例的胸主动脉腔内修复术提供参考。

研究设计与样本

  • 单中心研究,2018年2月至2022年4月共纳入44例累及三支主动脉弓分支的患者,其中主动脉弓动脉瘤14例、主动脉弓夹层30例(急性主动脉弓夹层22例、长期主动脉弓夹层8例)。
  • 患者中男性34例、女性10例,平均年龄59.84±11.72岁。
  • 根据计算机断层血管造影图像制作三维打印模型,并用于引导医师改良支架的开窗制作;所有患者均接受随访。

主要发现

  • 共132支分支成功重建,无中转开放手术病例。
  • 平均手术时间4.97±1.40小时,其中支架定制平均44.05±7.72分钟;平均术后住院时间9.91±4.47天;平均术中出血量480.91 mL(100-2810 mL);平均术后重症监护监测时间1.02天(0-5天)。
  • 术后30天内无死亡;术后神经系统并发症1例(2.3%),逆行A型夹层1例(2.3%)。

临床怎么用

  • 作者认为,三维打印引导下的三支主动脉弓分支重建与传统手术相比是一种微创治疗方法,具有定位准确、术后恢复快、并发症少以及短期至中期疗效可靠的优点。
  • 作者指出,三维打印技术可将影像数据转化为三维模型,提高开窗定位的准确性;缩径技术和内置小袖套技术补充了简化开窗选择流程并降低了内漏发生率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To summarize experience with and the efficacy of fenestrated/branched thoracic endovascular repair (F/B-TEVAR) using physician-modified stent-grafts (PMSGs) under 3D printing guidance in triple aortic arch branch reconstruction. MATERIALS AND METHODS: From February 2018 to April 2022, 14 cases of aortic arch aneurysms and 30 cases of aortic arch dissection (22 acute aortic arch dissection and 8 long-term aortic arch dissection)were treated by F/B-TEVAR in our department, including 34 males and 10 females, with an average age of 59.84 ± 11.72 years. Three aortic arch branches were affected in all patients. A 3D-printed model was made according to computed tomography angiography images and used to guide the fabrication of PMSGs. All patients were followed up. RESULTS: A total of 132 branches were successfully reconstructed with no case of conversion to open surgery. The average operation time was 4.97 ± 1.40 hours, including a mean 44.05 ± 7.72 minutes for stent-graft customization, the mean postoperative hospitalization duration was 9.91 ± 4.47 days, the average intraoperative blood loss was 480.91 mL (100-2810 mL), and the mean postoperative intensive care unit monitoring duration was 1.02 days (0-5 days). No deaths occurred within 30 days of surgery. Postoperative neurological complications occurred in 1 case (2.3%), and retrograde type A dissection occurred in 1 case (2.3%). CONCLUSION: Compared with conventional surgery, triple aortic arch branch reconstruction under the guidance of 3D printing is a minimally invasive treatment method with the advantages of accurate positioning, rapid postoperative recovery, few complications, and reliable short- to mid-term effects. CLINICAL IMPACT: At present the PMSG usually depend on imaging data and software calculation. With the guidance of 3D printing technology, image data could be transformed into 3D model, which has improved the accuracy of the positioning of the fenestrations. The diameter reduction technique and the internal mini cuff technique have made a complement to the slimed-down fenestration selection process and the low rate of endoleak. As reproducible study, our results may provide reference for TEVAR in different cases.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Fu DS, Jin Y, Zhao ZH, et al. Three-Dimensional Printing to Guide Fenestrated/Branched TEVAR in Triple Aortic Arch Branch Reconstruction With a Curative Effect Analysis. J Endovasc Ther. 2023. PMID: 36942654. doi:10.1177/15266028231161244

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。