比较径向与套层激光光纤尖端对大隐静脉主干反流腔内激光消融术结局的影响
该回顾性分析纳入2020至2022年74例(85条肢体)大隐静脉反流患者,比较径向与套层激光光纤尖端行腔内激光消融术的技术成功率与并发症。技术成功78条肢体(92.9%),两组技术成功率及疼痛、瘀斑、再通、血肿、浅静脉血栓和VCSS评分差异均无统计学意义。结论认为光纤尖端配置对结局无显著影响。
要点
- 径向光纤组技术成功率94.1%,套层光纤组90%,差异无统计学意义(P=0.18)。
- 术后疼痛、瘀斑、再通、血肿及浅静脉血栓与光纤尖端配置无显著关联。
- 两组间静脉临床严重程度评分(VCSS)差异无统计学意义(P=0.14)。
核心结论
- 激光光纤尖端配置或其品牌对大隐静脉反流腔内激光消融术的结局无显著影响。
- 径向与套层激光光纤尖端在腔内激光消融术中表现出相似的安全性和有效性。
研究设计与样本
- 回顾性分析,纳入2020至2022年记录有大隐静脉反流的患者。
- 共74例患者(85条肢体)接受腔内激光消融术,其中径向光纤54条、套层光纤32条。
- 纳入标准为年龄超过18岁、原发性静脉曲张、无恶性肿瘤和血液系统疾病、记录有大隐静脉反流超过0.5秒。
- 所有患者均行大隐静脉腔内激光消融术,根据需要辅以泡沫硬化治疗或门诊静脉切除术。
主要发现
- 技术成功78条肢体(92.9%),6条肢体(7.1%)在1个月时大隐静脉近端3 cm再通。
- 2例患者出现血肿,5例患者出现浅静脉血栓。
- 术后疼痛、瘀斑、再通、血肿形成和浅静脉血栓与不同激光光纤尖端配置无显著关联(P值分别为0.95、0.6、0.18、1和1)。
- 两组间VCSS评分无显著差异(P=0.14)。
- 技术成功率套层光纤组为90%,径向光纤组为94.1%(P=0.18)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Saphenous vein reflux is one of the leading causes of cosmetic and functional disabilities. The recent European Society of Vascular Surgery guidelines recommend endovenous thermal ablation over surgery or sclerotherapy for the treatment of great saphenous vein (GSV) reflux in patients with chronic venous disease. The aim of this study is to compare different laser fiber tip configurations to outcome regarding technical success and incidence of complications. DESIGN: A retrospective analysis conducted on patients with documented GSV reflux from 2020 to 2022, comparing baseline parameters and outcome between 2 groups of laser tip fibers used; radial tip and jacketed tip. Primary end point was technical success. Secondary endpoints included incidence of complications in each group, and VCSS score difference in both groups. METHODS: Inclusion criteria entailed patients with primary varicose veins over the age of 18 years, free from malignancy, hematological disorders, and having documented GSV reflux of more than 0.5 sec. All patients had endovenous laser ablation (EVLA) of the GSV, with complementary foam sclerotherapy or ambulatory phlebectomies as required. RESULTS: A total of 74 patients underwent EVLA (85 limbs). Fifty-four were done using the radial laser fibers, and 32 using jacketed fibers. Technical success was achieved in 78 limbs (92.9%), 6 limbs (7.1%) had recanalization of the proximal 3 cm of the GSV at 1 month, 2 patients experienced hematomas, and 5 patients had superficial vein thrombosis. There was no significant association between postoperative pain, bruising, recanalization, hematoma formation, and superficial vein thrombosis with different laser fiber tip configurations (P-value 0.95, 0.6, 0.18, 1, and 1, respectively), nor was there any significant difference in VCSS between them (P-value 0.14).Technical success was 90% in the jacketed fibers and 94.1% in the radial fibers group (P-value 0.18). CONCLUSIONS: Neither does laser fiber tip configuration nor its make have a significance on outcome of EVLA of GSV reflux. Both radial and jacketed laser fiber tips exhibit similar safety and efficacy in EVLA.
引用
- Zaki MM, Tawfick SE, Gohar KS, et al. Comparing the Effects of Radial and Jacketed Laser Tip Fibers on Outcome of Endovenous Laser Ablation of Lower Limb Truncal Venous Reflux. Ann Vasc Surg. 2023. PMID: 36746271. doi:10.1016/j.avsg.2023.01.045
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。