文献速递颈动脉与弓上血管

经股动脉颈动脉支架置入术中应用远端栓塞保护与院内结局改善相关

Distal embolic protection use during transfemoral carotid artery stenting is associated with improved in-hospital outcomes.
PubMed 文献 · J Vasc Surg · 2023-02-14

基于血管质量倡议(Vascular Quality Initiative)2005年3月至2021年12月的数据,在29853例经股动脉颈动脉支架置入术(tfCAS)患者中,95%尝试放置远端滤器。倾向性评分匹配后,未尝试放置滤器与院内卒中/死亡、卒中和死亡率显著升高相关。滤器放置失败者的卒中/死亡风险与未尝试放置者相当,但高于成功放置滤器者。

要点

  • tfCAS未尝试远端栓塞保护与院内卒中/死亡风险显著升高相关(aRR 1.72)。
  • 滤器放置失败者卒中/死亡风险较成功放置滤器者升高两倍以上(aRR 2.10)。
  • 滤器放置失败与未尝试放置的结局无显著差异。

主要发现

  • 在29853例接受tfCAS的患者中,28213例(95%)尝试了远端栓塞保护滤器,1640例(5%)未尝试。
  • 匹配后纳入6859例患者,未尝试放置滤器与院内卒中/死亡风险显著升高相关(6.4% vs 3.8%;aRR 1.72;95%CI 1.32-2.23;P < .001)。
  • 未尝试放置滤器与院内卒中风险显著升高相关(3.7% vs 2.5%;aRR 1.49;95%CI 1.06-2.08;P = .022)。
  • 未尝试放置滤器与院内死亡风险显著升高相关(3.5% vs 1.7%;aRR 2.07;95%CI 1.42-3.020;P < .001)。
  • 滤器放置失败与成功放置相比,卒中/死亡(5.8% vs 2.7%;aRR 2.10;95%CI 1.38-3.21;P = .001)和卒中(5.3% vs 1.8%;aRR 2.87;95%CI 1.78-4.61;P < .001)风险更高;滤器放置失败与未尝试放置相比,卒中/死亡(5.4% vs 6.2%;aRR 0.99;95%CI 0.61-1.63;P = .99)、卒中(4.7% vs 3.7%;aRR 1.40;95%CI 0.79-2.48;P = .20)和死亡(0.9% vs 3.4%;aRR 0.35;95%CI 0.12-1.01;P = .052)无显著差异。

关键数值与推荐

  • 作者结论支持当前血管外科学会(Society for Vascular Surgery)指南推荐在tfCAS中常规使用远端栓塞保护。
  • 作者认为若滤器无法安全放置,应考虑颈动脉血运重建的替代方法。

临床怎么用

  • 作者结论支持当前血管外科学会(Society for Vascular Surgery)指南推荐在tfCAS中常规使用远端栓塞保护。
  • 作者认为若滤器无法安全放置,应考虑颈动脉血运重建的替代方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Despite current guidelines recommending the use of distal embolic protection during transfemoral carotid artery stenting (tfCAS) to prevent periprocedural stroke, there remains significant variation in the routine use of distal filters. We sought to assess in-hospital outcomes in patients undergoing tfCAS with and without embolic protection using a distal filter. METHODS: We identified all patients undergoing tfCAS in the Vascular Quality Initiative from March 2005 to December 2021 and excluded those who received proximal embolic balloon protection. We created propensity score-matched cohorts of patients who underwent tfCAS with and without attempted placement of a distal filter. Subgroup analyses of patients with failed vs successful filter placement and failed vs no attempt at filter placement were performed. In-hospital outcomes were assessed using log binomial regression, adjusted for protamine use. Outcomes of interest were composite stroke/death, stroke, death, myocardial infarction (MI), transient ischemic attack (TIA), and hyperperfusion syndrome. RESULTS: Among 29,853 patients who underwent tfCAS, 28,213 (95%) had a filter attempted for distal embolic protection and 1640 (5%) did not. After matching, 6859 patients were identified. No attempted filter was associated with significantly higher risk of in-hospital stroke/death (6.4% vs 3.8%; adjusted relative risk [aRR], 1.72; 95% confidence interval [CI], 1.32-2.23; P < .001), stroke (3.7% vs 2.5%; aRR, 1.49; 95% CI, 1.06-2.08; P = .022), and mortality (3.5% vs 1.7%; aRR, 2.07; 95% CI, 1.42-3.020; P < .001). In a secondary analysis of patients who had failed attempt at filter placement vs successful filter placement, failed filter placement was associated with worse outcomes (stroke/death: 5.8% vs 2.7%; aRR, 2.10; 95% CI, 1.38-3.21; P = .001 and stroke: 5.3% vs 1.8%; aRR, 2.87; 95% CI, 1.78-4.61; P < .001). However, there were no differences in outcomes in patients with failed vs no attempted filter placement (stroke/death: 5.4% vs 6.2%; aRR, 0.99; 95% CI, 0.61-1.63; P = .99; stroke: 4.7% vs 3.7%; aRR, 1.40; 95% CI, 0.79-2.48; P = .20; death: 0.9% vs 3.4%; aRR, 0.35; 95% CI, 0.12-1.01; P = .052). CONCLUSIONS: tfCAS performed without attempted distal embolic protection was associated with a significantly higher risk of in-hospital stroke and death. Patients undergoing tfCAS after failed attempt at filter placement have equivalent stroke/death to patients in whom no filter was attempted, but more than a two-fold higher risk of stroke/death compared with those with successfully placed filters. These findings support current Society for Vascular Surgery guidelines recommending routine use of distal embolic protection during tfCAS. If a filter cannot be placed safely, an alternative approach to carotid revascularization should be considered.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Wang SX, Marcaccio CL, Patel PB, et al. Distal embolic protection use during transfemoral carotid artery stenting is associated with improved in-hospital outcomes. J Vasc Surg. 2023. PMID: 36796592. doi:10.1016/j.jvs.2023.01.210

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。