指南与共识主动脉疾病

腹主动脉瘤在指南推荐直径以下修复的频率与指征特征

Characterizing the frequency and indications for repair of abdominal aortic aneurysms with diameters smaller than recommended by societal guidelines.
指南 / 共识 · J Vasc Surg · 2023-02-10

单中心回顾性分析2010—2020年456例择期腹主动脉瘤修复,147例(32%)低于指南直径推荐(男性<5.5 cm、女性<5.0 cm);血管质量倡议(VQI)44,820例中17,057例(38%)低于推荐。低于推荐者院内死亡更低(开放修复2.4% vs 4.6%,P<.0001;EVAR 0.3% vs 0.8%,P<.0001)。作者将单中心原因构成外推至全国,估计约10,064例有可接受的其他指征,6,993例无记录指征(相关35例死亡)。

要点

  • 单中心32%、VQI 38%的择期腹主动脉瘤修复直径低于指南推荐。
  • 低于推荐者院内死亡更低:开放修复2.4% vs 4.6%,EVAR 0.3% vs 0.8%(均P<.0001)。
  • 单中心低于推荐修复中41%无记录原因,23%为髂动脉瘤,10%为囊状,10%为快速扩张。

核心结论

  • 低于指南直径推荐的腹主动脉瘤修复在VQI和单中心均约占全部择期修复的三分之一。
  • 假设本中心实践具有代表性,近60%低于直径推荐的修复符合其他明确原因,其余40%无记录原因,意味着全部择期修复中13%为低于推荐且无可接受指征。

研究设计与样本

  • 单中心回顾性 review,纳入2010—2020年全部择期开放腹主动脉瘤修复(oAAA)和腹主动脉瘤腔内修复(EVAR),评估低于直径推荐(男性<5.5 cm、女性<5.0 cm)修复的发生率和指征。
  • 查询血管质量倡议(VQI)2010—2020年全部无症状oAAA和EVAR,识别低于直径推荐的修复,并将单中心分析结果应用于VQI队列以 extrapolate 全国原因估计。
  • 比较低于与符合直径推荐者的院内死亡和主要不良心脏事件(MACE)。

主要发现

  • 本中心456例择期AAA修复中147例(32%)低于直径推荐,EVAR中更常见(35% vs 28%)。
  • 低于推荐修复的原因:未记录41%、髂动脉瘤23%、囊状10%、快速扩张10%、患者焦虑7%、其他6%、远端栓塞3%。
  • VQI 44,820例择期AAA修复中17,057例(38%)低于直径推荐(EVAR 40%,oAAA 26%)。
  • 低于推荐者院内死亡更低:oAAA 2.4% vs 4.6%(P<.0001);EVAR 0.3% vs 0.8%(P<.0001)。
  • 将单中心结果应用于VQI,估计全国10,064例修复因尺寸标准以外的可接受指征实施,另有6,993例修复(相关35例死亡)无记录指征。

关键数值与推荐

  • 血管外科学会推荐男性AAA直径≥5.5 cm、女性≥5.0 cm时修复。
  • 低于直径推荐定义为男性<5.5 cm、女性<5.0 cm。
  • 低于推荐修复的原因分类为:髂动脉瘤、囊状形态、快速扩张、患者焦虑、远端栓塞、其他、无记录原因。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Although the Society for Vascular Surgery recommends repair of abdominal aortic aneurysms (AAA) at 5.5 cm or greater in men and 5.0 cm or greater in women, AAA repair below these thresholds has been well-documented. There are clear indications for repair other than these strict size criteria, but the expected proportion of such repairs in one's practice has not been studied. We sought to characterize the indications for repairs of aneurysms below diameter recommendations at a single academic center. Using the assumption that this real-world experience would approximate that of other practices, we then used national data to extrapolate these findings. METHODS: A single-center retrospective review was conducted of all elective open AAA (oAAA) and endovascular aneurysm repair (EVAR) from 2010 to 2020 to assess the incidence of and indications for repair of aneurysms below diameter recommendations (defined as <5.5 cm in men and <5.0 cm in women). Reasons for these repairs were defined as (1) iliac aneurysm, (2) saccular morphology, (3) rapid expansion, (4) patient anxiety, (5) distal embolization, (6) other, and (7) no documented reason. The Vascular Quality Initiative (VQI) was queried for all asymptomatic oAAA and EVAR (2010-2020) and repairs below diameter recommendations were identified. Findings from the single-center analysis were applied to the VQI cohort to extrapolate estimates of reasons for repairs done nationally. In-hospital mortality and major adverse cardiac events (MACE) were compared between those below size recommendations and those meeting size recommendations. RESULTS: Of 456 elective AAA repairs at our center, 147 (32%) were below size recommendations. This finding was more common for EVAR (35% vs 28%). Reasons were: not documented (41%), iliac aneurysm (23%), saccular (10%), rapid expansion (10%), patient anxiety (7%), other (6%), and distal embolism (3%). Of 44,820 elective AAA repairs in the VQI, 17,057 (38%) were below size recommendations (40% EVAR, 26% oAAA). Patients who were repaired below size recommendations had lower in-hospital death (oAAA, 2.4% vs 4.6% [P < .0001]; EVAR, 0.3% vs 0.8% [P < .0001]). When single-center findings were applied to the VQI dataset, an estimated 10,064 repairs were performed nationally for acceptable indications other than size criteria. Conversely, there may have been 6993 repairs (with an associated 35 deaths) performed without documented indication. CONCLUSIONS: Repairs for AAA below the recommended diameter guidelines account for approximately one-third of all elective AAA procedures in both the VQI and our single-center experience. Assuming our practice is typical, nearly 60% of repairs below size recommendations meet the criteria for other clear reasons. The remaining 40% lack a documented reason, meaning that 13% of all elective AAA repairs were done for aneurysms below size recommendations without an acceptable indication. As awareness of overuse and underuse is heightened, these data help to estimate the expected proportion of repairs for less common pathologies. They also provide a potential baseline data point for efforts at decreasing overuse.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Fan EY, Buckner MA, LiCausi J, et al. Characterizing the frequency and indications for repair of abdominal aortic aneurysms with diameters smaller than recommended by societal guidelines. J Vasc Surg. 2023. PMID: 36773667. doi:10.1016/j.jvs.2023.01.201

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。