编辑推荐——在分流模拟研究队列中为实现新创建动静脉内瘘的功能性而进行的干预
分流模拟研究纳入荷兰9个透析中心2015至2018年需要首次动静脉内瘘的222例患者,随访至内瘘创建后1年。约34%的内瘘需要干预以实现功能性,其中68%最终成为功能性;无辅助功能为54%,总体功能为78%。临床成功干预者的术前静脉直径更大且血栓性内瘘更少;辅助功能内瘘与无辅助功能内瘘的 secondary patency 相似,但每年所需干预更多。
要点
- 约三分之一的新创建动静脉内瘘需要干预以实现功能性,其中68%最终成为功能性。
- 临床成功干预者术前静脉直径更大(2.8 ± 1.0 mm vs. 2.3 ± 0.6 mm,p = .036),血栓性内瘘更少(7% vs. 43%,p = .006)。
- 辅助功能内瘘与无辅助功能内瘘的 secondary patency 相似(6个月时100%和98%,p = .44),但每年所需干预更多(2.6 vs. 1.7次/年;率比1.52,95% CI 1.04 - 2.18,p = .032)。
核心结论
- 约三分之一的新创建动静脉内瘘需要干预以实现功能性;大多数血栓性内瘘被放弃,且选择进行血栓切除术时很少达到临床成功;通畅内瘘为实现功能性的干预临床成功率高,因此可以重复进行直至内瘘成为功能性。
研究设计与样本
- 分流模拟研究为多中心前瞻性队列研究,纳入荷兰9个透析中心2015至2018年需要首次动静脉内瘘的222例患者,随访至内瘘创建后1年。
- 本观察性研究分析了基于病变和干预特征为实现功能性而进行的干预的技术和临床成功率,并比较了辅助功能和无辅助功能动静脉内瘘的临床结局。
主要发现
- 研究结束时接受透析治疗的患者中,无辅助内瘘功能为54%,总体内瘘功能为78%。
- 34%的动静脉内瘘需要干预以实现功能性,其中68%最终成为功能性;这些干预中75%为血管通路狭窄的经皮球囊血管成形术。
- 临床成功干预者术前静脉直径更大(2.8 ± 1.0 mm vs. 2.3 ± 0.6 mm,p = .036),血栓性内瘘更少(7% vs. 43%,p = .006)。
- 辅助功能内瘘与无辅助功能内瘘的 secondary patency 相似(6个月时100%和98%,p = .44),但每年所需干预更多(2.6 vs. 1.7次/年;率比1.52,95% CI 1.04 - 2.18,p = .032)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Although observational cohort studies report that interventions to achieve functionality are clinically successful in 85% of patients, the proportion of newly created autologous arteriovenous fistulas that result in functional vascular access typically is only 70 - 80%. To address this discrepancy, the selection and outcomes of interventions to achieve functionality in a multicentre prospective cohort study were analysed. METHODS: The Shunt Simulation Study enrolled 222 patients who needed a first arteriovenous fistula in nine dialysis units in The Netherlands from 2015 to 2018 and followed these patients until one year after access creation. In this observational study, the technical and clinical success rates of interventions to achieve functionality based on lesion and intervention characteristics were analysed and the clinical outcomes of arteriovenous fistulas with assisted and unassisted functionality were compared. RESULTS: For patients who were on dialysis treatment at the end of the study, unassisted fistula functionality was 54% and overall fistula functionality was 78%. Thirty-four per cent of arteriovenous fistulas required an intervention to achieve functionality, 68% of which eventually became functional. Seventy-five per cent of these interventions were percutaneous balloon angioplasties of vascular access stenoses. Patients with clinically successful interventions to achieve functionality had larger pre-operative vein diameters (2.8 ± 1.0 mm vs. 2.3 ± 0.6 mm, p = .036) and less often presented with thrombosed fistulas than patients with unsuccessful interventions (7% vs. 43%, p = .006). Arteriovenous fistulas with assisted functionality had similar secondary patency as fistulas with unassisted functionality (100% and 98% at six months, p = .44), although they required more interventions to maintain function (2.6 vs. 1.7 per year; rate ratio 1.52, 95% CI 1.04 - 2.18, p = .032). CONCLUSION: Interventions to achieve functionality were needed in about a third of newly created arteriovenous fistulas. Most thrombosed fistulas were abandoned, and when selected for thrombectomy rarely reached clinical success. On the other hand, interventions to achieve functionality of patent fistulas had high clinical success rates and therefore can be done repeatedly until the fistula has become functional.
引用
- van Vliet LV, Zonnebeld N, Bouwman LH, et al. Editor's Choice - Interventions to Achieve Functionality in Newly Created Arteriovenous Fistulas in the Shunt Simulation Study Cohort. Eur J Vasc Endovasc Surg. 2023. PMID: 36646270. doi:10.1016/j.ejvs.2023.01.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。