球囊诱导再分层与假腔血栓形成治疗慢性B型主动脉夹层:技术与长期结果
该回顾性单中心观察性研究纳入8例慢性B型主动脉夹层已行胸主动脉腔内修复且假腔逆流经球囊诱导再分层与假腔血栓形成(BAILOUT)技术矫正的患者,技术成功率和临床成功率均为100%,中位随访62.5个月无主动脉直径增加,3年时全部患者假腔完全血栓形成,作者认为该技术安全可行,但样本量小和回顾性设计是局限。
要点
- BAILOUT技术通过球囊破裂夹层内膜片实现再分层,阻断假腔逆流。
- 8例患者技术成功率和临床成功率均为100%,无早期再干预。
- 中位随访62.5个月,无主动脉直径增加,3年时全部患者假腔完全血栓形成。
核心结论
- BAILOUT技术在小样本队列中安全可行,是克服慢性B型夹层假腔逆流的简单快捷方法。
研究设计与样本
- 观察性、回顾性、单中心研究,分析2006年至2020年间8例慢性B型主动脉夹层已行胸主动脉腔内修复且假腔逆流经BAILOUT矫正的非连续队列患者。
主要发现
- 技术成功率和临床成功率均为100%,假腔逆流完全中断。
- 无早期手术再干预,中位随访62.5个月(四分位距43.2-94.1)期间仅1例死亡与手术无关。
- 术后1个月、3个月、1年、5年和7年无主动脉相关不良事件生存率分别为87.5%、62.5%、62.5%、62.5%和62.5%。
- 随访期间无胸主动脉直径增加,3年时全部患者CT血管造影显示假腔完全血栓形成。
临床怎么用
- 原文未据此给出推荐。
局限性
- 小样本和回顾性设计是研究的局限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To evaluate the safety, feasibility, and effectiveness of the BAlloon Inducted re-Lamination and false lUmen Thrombosis (BAILOUT) as a simple technique to address the retrograde false lumen (FL) perfusion and subsequent aneurysmatic degeneration of the thoracic aorta due to a stent-graft crimped in a small true lumen in chronic Type B dissections. METHODS: An observational, retrospective, single-center study analyzing a nonconsecutive cohort of 8 patients affected by chronic type B aortic dissections already treated with thoracic endovascular repair and with an FL lumen backflow corrected with BAILOUT between 2006 and 2020. After a standard distal extension of the previously implanted graft, the distal end of the graft area was ballooned to completely rupture the dissection lamella to relaminate the aorta hindering the FL backflow. Computed tomography was routinely performed within the first postoperative week before discharge and then at 3 months, at 6 months, and yearly thereafter. The technical and clinical success rates were analyzed. Primary outcomes were safety and feasibility of the technique, secondary ones included FL thrombosis evaluation, and total aortic diameter analysis at the above-defined levels during the follow-up. Safety was defined if clinical success was reached. Feasibility was intended as technical success obtention. RESULTS: The technical and clinical success achieved was 100% with the complete interruption of FL backflow stating the safety and feasibility of the BAILOUT technique. No early procedure reinterventions were recorded and during a median follow-up of 62.5 months [interquartile range 43.2-94.1], only 1 death unrelated to the procedure was recorded. Freedom from aortic-related adverse events at 1 month, 3 months, 1 year, 5, and 7 years was 87.5%, 62.5%, 62.5%, 62.5%, and 62.5%, respectively. During the follow-up, no one increment of the diameter of the thoracic aorta was documented and all the patients at 3 years of computed tomography angiography showed a complete FL thrombosis. CONCLUSIONS: The BAILOUT technique demonstrates to be safe and feasible in this small cohort of patients as a simple and quick way to overcome the issue of FL backflow in chronic type B dissection. Small cohort and retrospective designs were limitations of the study.
引用
- Gennai S, Andreoli F, Leone N, et al. Balloon Inducted Re-Lamination and False Lumen Thrombosis in Chronic Type B Aortic Dissection: Technique and Long-Term Results. Ann Vasc Surg. 2023. PMID: 36646251. doi:10.1016/j.avsg.2022.12.091
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。