文献速递外周动脉疾病

逆行球囊辅助方法在复杂再通术中预防远端栓塞

Retrograde Balloon-Assisted Approach to Prevent Distal Embolization During Complex Recanalization Procedures.
PubMed 文献 · J Endovasc Ther · 2022-11-22

该技术描述了一种利用通用现成器械的补救性策略:通过逆行入路在膝下目标血管远端置入并扩张低profile球囊,以拦截再通操作(如斑块旋切和机械血栓切除)产生的碎屑;完成血运重建后,经4F弯导管顺行抽吸碎屑。作者认为,在膝下血运重建存在固有远端栓塞风险、尤其远端单支血管流出时,可考虑该逆行球囊辅助的现成栓塞保护方法。

要点

  • 逆行球囊辅助的现成栓塞保护方法可用于膝下血运重建中固有远端栓塞风险增高的场景。
  • 在可能产生远端栓塞的近端操作前,经远端逆行入路置入并扩张低profile球囊以拦截碎屑。
  • 完成血运重建后,经4F弯导管顺行抽吸可能存在的远端栓塞碎屑。

核心结论

  • 对于膝下血运重建术中固有远端碎屑风险增高、尤其是存在远端单支血管流出时,可考虑采用逆行球囊辅助的现成栓塞保护方法。

研究设计与样本

  • 该研究为技术描述,介绍一种利用通用现成器械预防膝下远端栓塞的补救性技术策略。

主要发现

  • 通过逆行入路在膝下目标血管置入并扩张低profile球囊,可利用球囊扩张产生的停滞血柱拦截再通操作产生的碎屑。
  • 完成血运重建后,经4F弯导管顺行推进至远端扩张球囊处,若发生远端栓塞可按标准方式抽吸碎屑。

临床怎么用

  • 作者认为,在膝下血运重建术中固有远端碎屑风险增高、尤其是存在远端单支血管流出时,可考虑采用逆行球囊辅助的现成栓塞保护方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of the study is to describe a bailout technical strategy to prevent below-the-knee (BTK) distal embolization during procedures with increased inherent risk using universally-available "off-the-shelf" devices. TECHNIQUE: A conventional retrograde access is obtained of the BTK target vessel where embolization protection is sought. Before starting any potential proximal maneuver with an associated significant risk of distal embolization (eg, atherectomy and mechanical thrombectomy), a low-profile balloon is inserted and inflated through the distal retrograde access, so that any debris resulting from the recanalization procedure is blocked by the stagnant column of blood generated by the inflated balloon. Once the revascularization procedure has been completed, a 4F curved catheter is antegradely advanced down to the distally-inflated balloon, and in case of distal embolization the debris is aspirated in a standard fashion way. CONCLUSION: A retrograde balloon-assisted "off-the-shelf" embolic protection approach may be considered for BTK revascularization procedures where there is an inherent increased risk of distal trash, especially in the presence of distal single-vessel runoff. CLINICAL IMPACT: Distal embolization following endovascular procedures can have devastating consequences and there is a general recommendation for selective use of EPDs in high-risk-scenarios. The increased cost and low availability of the current EPD devices for BTK/BTA arteries have prohibited their widespread use. The retrograde balloon-assisted "off-the-shelf" EPD prevents distal embolization during procedures with increased risk of distal trash using inexpensive, nonspecific equipment available in any basic endovascular suite.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Ysa A, Lobato M, Arroniz A, et al. Retrograde Balloon-Assisted Approach to Prevent Distal Embolization During Complex Recanalization Procedures. J Endovasc Ther. 2022. PMID: 36415934. doi:10.1177/15266028221138024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。