文献速递主动脉疾病

胸主动脉腔内修复术中采用Knickerbocker技术阻断B型主动脉夹层逆行假腔血流的单中心初步经验

Initial Single-Center Experience With the Knickerbocker Technique During Thoracic Endovascular Aortic Repair to Block Retrograde False Lumen Flow in Patients With Type B Aortic Dissection.
PubMed 文献 · J Endovasc Ther · 2022-11-07

该单中心回顾性分析纳入11例B型主动脉夹层患者,在胸主动脉腔内修复术中采用Knickerbocker技术阻断逆行假腔血流。术中造影显示9/11例(82%)在球囊扩张水平成功封闭假腔,围手术期死亡1例(9%)。随访3个月时,球囊扩张水平近端胸主动脉100%患者假腔完全血栓化,但支架移植物远端内脏水平假腔通畅率仍高(假腔血栓形成率11%),导致该水平及肾下腹主动脉扩张。

要点

  • Knickerbocker技术 feasible 且有效,使支架移植物覆盖段主动脉获得正向重构。
  • 术中球囊扩张水平假腔成功封闭率为82%(9/11例),围手术期死亡1例(9%)。
  • 3个月随访时,球囊扩张近端胸主动脉100%患者假腔完全血栓化,但内脏水平假腔血栓形成率仅11%。

核心结论

  • Knickerbocker技术可行且有效,在一小队列患者中使支架移植物覆盖的主动脉获得正向重构。

研究设计与样本

  • 单中心回顾性分析,连续纳入所有接受Knickerbocker技术阻断逆行假腔血流的主动脉夹层患者,共11例。

主要发现

  • 术中控制造影显示11例中9例(82%)在球囊扩张水平成功封闭假腔。
  • 围手术期死亡1例(9%),原因为卒中。
  • 早期再干预2例,分别因腹膜后出血和左锁骨下动脉 bypass 后颈部乳糜漏。
  • 中位临床随访6个月(四分位距2-11个月),随访期间死亡2例:1例于TEVAR后2个月不明原因死亡,1例于11个月后因升主动脉假性动脉瘤破裂死亡。
  • 3个月随访时,球囊扩张水平近端胸主动脉100%患者显示假腔完全血栓化,假腔直径减小(100%),总主动脉直径稳定(44%)或减小(56%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Effectiveness of thoracic endovascular aortic repair in type B aortic dissection is impaired by persistent retrograde false lumen flow via distal re-entry tears. Controlled, stentgraft-assisted balloon dilatation of the true lumen at its lower end, or Knickerbocker technique, may block retrograde false lumen flow and consequently improve effectiveness by inducing immediate thrombosis along the entire descending thoracic aorta. MATERIALS AND METHODS: A single-center retrospective analysis was performed for all consecutive patients with aortic dissection treated with the Knickerbocker technique to block retrograde false lumen flow. RESULTS: Eleven patients were included for analysis. Intraoperative control angiography showed successful occlusion of the false lumen at the level of balloon dilatation in 9 out of 11 patients (82%). There was one perioperative mortality (9%), due to stroke. There were 2 early reinterventions, due to retroperitoneal bleeding and due to chyle leakage in the neck after left subclavian artery bypass. Median clinical follow-up duration was 6 (interquartile range [IQR] 2-11] months. There were 2 deaths during follow-up, one at 2 months after TEVAR from unknown cause of death, and one after 11 months due to rupture of an ascending aortic pseudoaneurysm. The Knickerbocker technique led to positive aortic remodeling. At 3 months follow-up, 100% of patients showed complete false lumen thrombosis in the thoracic aorta proximal to the level of balloon dilatation, with decreasing false lumen diameters (100%) and stable (44%) or decreasing (56%) total aortic diameters. In most patients, the false lumen distal to the stentgraft (i.e. at visceral level) remained patent (11% false lumen thrombosis rate), leading to ≥2 mm dilatation at this level (78% of patients) and in the infrarenal abdominal aorta (56% of patients) at 3 months postoperatively. No distal stent-graft-induced new entry tears were noticed during follow-up. CONCLUSION: The Knickerbocker technique is feasible and effective, leading to positive aortic remodeling of the aorta covered by stentgraft in all of a small cohort of patients. CLINICAL IMPACT: Persistent, retrograde false lumen perfusion from distal re-entries following thoracic endovascular aortic repair (TEVAR) for Stanford type B aortic dissection, may lead to progressive, aneurysmal dilatation. Controlled, stent graft-assisted balloon dilatation of the true lumen in the distal descending aorta (i.e. Knickerbocker technique) during TEVAR effectively excludes the false lumen from persistent flow resulting in positive aortic remodeling in our small cohort of patients, and hence potentially eliminates the risk of late post-dissection aneurysm formation in the descending thoracic aorta.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. de Beaufort HWL, Vos JA, Heijmen RH, et al. Initial Single-Center Experience With the Knickerbocker Technique During Thoracic Endovascular Aortic Repair to Block Retrograde False Lumen Flow in Patients With Type B Aortic Dissection. J Endovasc Ther. 2022. PMID: 36342189. doi:10.1177/15266028221134889

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。