文献速递主动脉疾病

考虑低血压相关主动脉直径减小情况下钝性胸主动脉损伤主动脉覆膜支架的最佳尺寸选择

Optimal Sizing of Aortic Stent Graft for Blunt Thoracic Aortic Injury Considering Hypotension-Related Decrease in Aortic Diameter.
PubMed 文献 · J Endovasc Ther · 2022-11-07

本研究纳入2014至2020年因钝性胸主动脉损伤行胸主动脉腔内修复术的25例患者,比较急诊室初始CT、术中主动脉造影及门诊最终CT的主动脉尺寸。结果显示,血流动力学不稳定(收缩压≤90 mmHg或平均压≤70 mmHg)患者主动脉直径在术中及随访时显著增大;作者认为对此类患者选用130%oversizing的支架可减少内漏且足够安全。

要点

  • 血流动力学不稳定患者术中主动脉直径可能较正常状态缩小超过15%。
  • 本研究中支架平均按初始造影130%oversizing置入,按最终CT为122%。
  • 作者认为收缩压≤90 mmHg或平均压≤70 mmHg者可选用130%oversizing支架。

核心结论

  • 在血流动力学不稳定且收缩压(术中)≤90 mmHg或平均压(术中)≤70 mmHg时,尽管已充分复苏,选用130%oversizing的胸主动脉腔内修复支架可减少内漏发生且足够安全。

研究设计与样本

  • 回顾性纳入2014至2020年因钝性胸主动脉损伤行胸主动脉腔内修复术的25例患者,收集急诊室及术前血流动力学参数,测量初始CT、术中主动脉造影及门诊最终CT的主动脉尺寸。

主要发现

  • 最终CT/初始CT与最终CT/初始造影(近端降胸主动脉)的平均值分别为113%和105%。
  • 收缩压(术中)≤90 mmHg者最终CT/初始CT(近端降胸主动脉)为122.2% vs 108.8%(p=0.01),最终CT/初始造影为113.4% vs 102.1%(p<0.01),均显著高于收缩压(术中)>90 mmHg者。
  • 平均压(术中)≤70 mmHg者最终CT/初始CT(近端降胸主动脉)为120.4% vs 109.0%(p=0.03),最终CT/初始造影为111.4% vs 102.6%(p=0.01),均显著高于平均压(术中)>70 mmHg者。
  • 置入支架平均按初始造影130%oversizing,基于最终CT为122%oversizing。

临床怎么用

  • 作者认为,对充分复苏后收缩压(术中)≤90 mmHg或平均压(术中)≤70 mmHg的血流动力学不稳定钝性胸主动脉损伤患者,可选用130%oversizing的胸主动脉腔内修复支架以减少内漏且足够安全。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the optimal sizing of an aortic stent graft in patients with blunt thoracic aortic injury (BTAI), considering the decrease in diameter in hypovolemic status. MATERIALS AND METHODS: From 2014 to 2020, 25 patients who underwent thoracic endovascular aortic repair (TEVAR) for BTAI were included. Hemodynamic parameters in the emergency room (ER) and just before the main procedure (MP) were collected. The aortic sizes were measured during initial computed tomography (CT) on arrival in the ER, aortography (AG) during TEVAR, and final CT in the outpatient clinic. The appropriateness of the inserted stent graft size was investigated. RESULTS: The mean values of the final CT/initial CT and final CT/initial AG (proximal descending thoracic aorta [pDTA]) were 113% and 105%, respectively. The final CT/initial CT (pDTA; 122.2% vs 108.8%, p=0.01) and final CT/initial AG (pDTA; 113.4% vs 102.1%, p<0.01) were significantly higher in patients with systolic blood pressure (SBP; MP) ≤90 mm Hg. The final CT/initial CT (pDTA; 120.4% vs 109.0%, p=0.03) and final CT/initial AG (pDTA; 111.4% vs 102.6%, p=0.01) were significantly higher in patients with mean blood pressure (MBP; MP) ≤70 mm Hg. On an average, the inserted stent grafts were oversized by 130% on initial AG. Based on the final CT scan, the inserted stent graft was as large as 122%. CONCLUSION: In the case of hemodynamic instability with SBP (MP) ≤90 mm Hg or MBP (MP) ≤70 mm Hg, despite adequate resuscitation, an oversized TEVAR stent graft of 130% can reduce the occurrence of endoleak and is sufficiently safe. CLINICAL IMPACT: Despite sufficient resuscitation, the aorta size measured during TEVAR in patients with hemodynamic instability with systolic BP <90 mmHg and mean BP <70 mmHg may be reduced by more than 15% compared to that in the normal state. In this study, the mean size of the stent grafts were oversized by 130% on initial aortography, but were oversized by 122% based on final CT. When the stent graft was oversized by 130% in TEVAR for hemodynamic unstable patient with BTAI, the patient reached the proper oversizing subsequent to hemodynamic recovery.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Bae M, Jeon CH. Optimal Sizing of Aortic Stent Graft for Blunt Thoracic Aortic Injury Considering Hypotension-Related Decrease in Aortic Diameter. J Endovasc Ther. 2022. PMID: 36342200. doi:10.1177/15266028221134894

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。