颈动脉内膜切除术后采用不同材料行补片血管成形术的临床结局相似
该回顾性队列研究纳入2010年1月至2020年12月在本三级转诊中心行初次颈动脉内膜切除术并采用牛心包补片或涤纶补片关闭切口的患者,比较远期随访结局。结果显示两组在短暂性脑缺血发作或脑血管意外、再狭窄、再干预及全因死亡率方面均无显著差异,牛心包补片组术后血肿发生率显著更低,涤纶补片组有3例补片感染而牛心包补片组无感染。
要点
- 牛心包补片与涤纶补片在颈动脉内膜切除术后远期TIA或CVA、再狭窄、再干预及全因死亡率方面无显著差异。
- 牛心包补片组术后30天内血肿发生率显著低于涤纶补片组(2% vs 6%,P = .047)。
- 涤纶补片组有3例补片感染,牛心包补片组无补片感染。
核心结论
- 该大型回顾性研究表明牛心包补片与涤纶补片具有相当的安全性和耐久性,提示两种补片均可安全用于颈动脉内膜切除术的补片血管成形术。
- 补片感染罕见,且在牛心包补片组中未发生。
研究设计与样本
- 回顾性队列研究,纳入2010年1月至2020年12月在本三级转诊中心行初次颈动脉内膜切除术并采用牛心包补片或涤纶补片关闭切口的全部患者。
- 2015年牛心包补片作为涤纶补片的替代材料引入。
- 共纳入417例颈动脉内膜切除术患者,其中254例(61%)接受牛心包补片,163例(39%)接受涤纶补片。
- 平均年龄70.2 ± 8.7岁,男性占67%。
- 牛心包补片组中位随访时间15个月(范围12-27个月),涤纶补片组42个月(范围16-60个月),P < .001。
主要发现
- 术后血肿(≤30天)在牛心包补片组显著更低(2% vs 6%,P = .047)。
- 短期结局无其他显著差异。
- 单变量Cox回归分析显示涤纶补片与牛心包补片对TIA或CVA(P = .106)、再狭窄(P = .211)、再干预(P = .549)及全因死亡率(P = .158)的效应估计无显著差异。
- 多变量分析调整混杂因素后仍无显著差异:TIA或CVA(P = .939)、再狭窄(P = .057)、再干预(P = .193)及全因死亡率(P = .742)。
- 涤纶补片组有3例患者发生补片感染,牛心包补片组无补片感染。
临床怎么用
- 作者认为牛心包补片与涤纶补片均可安全用于颈动脉内膜切除术的补片血管成形术。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Patch angioplasty during carotid endarterectomy (CEA) is commonly used to treat carotid artery stenosis. However, the choice of which patch to use remains a matter of debate. Autologous venous material has disadvantages such as wound-related problems at the harvest site and a prolonged intervention time. These limitations can be bypassed when synthetic or biological patches are used. Both materials have been associated with divergent advantages and disadvantages. Therefore, the aim of our study was to compare the long-term follow-up outcomes in patients who underwent CEA and closure with either a bovine pericardial patch (BPP) or polyester patch. METHODS: A retrospective cohort study was conducted including all patients who underwent primary CEA and closure with a BPP or a polyester patch between January 2010 and December 2020 at our tertiary referral center. In 2015, the BPP was introduced as an alternative for polyester. The primary outcome was the occurrence of transient ischemic attack (TIA) or cerebrovascular accident (CVA) during follow-up and secondary outcomes included restenosis, reintervention, all-cause mortality, and patch infection. Cox proportional hazard models were used and hazard ratios with 95% confidence intervals were used to predict these outcomes. RESULTS: We included 417 CEA patients; 254 patients (61%) received a BPP and 163 received (39%) a polyester patch. The mean age was 70.2 ± 8.7 years and 67% were male. The median follow-up time was 15 months (range, 12-27 months) for BPP and 42 months (range, 16-60 months) for polyester (P < .001). Postoperative hematoma (≤30 days) was significantly lower in the BPP cohort (2% BPP vs 6% polyester; P = .047). No other significant differences on short-term outcomes were found. Univariable Cox regression analyses showed no significant differences between the effect estimates of polyester and BPP on TIA or CVA (P = .106), restenosis (P = .211), reintervention (P = .549), or all-cause mortality (P = .158). No significant differences were found after adjusting for confounders in the multivariable analyses: TIA or CVA (P = .939), restenosis (P = .057), reintervention (P = .193) and all-cause mortality (P = .742). Three patients with a polyester patch had patch infection compared with none of the patients in the group who received a BPP. CONCLUSIONS: This large retrospective study showed comparable safety and durability of both BPP and polyester suggesting that both patch types can be safely applied for CEA with patch angioplasty. Patch infection was rare and was absent in the BPP group.
引用
- Liesker DJ, Gareb B, Looman RS, et al. Patch angioplasty during carotid endarterectomy using different materials has similar clinical outcomes. J Vasc Surg. 2022. PMID: 36208708. doi:10.1016/j.jvs.2022.09.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。