文献速递主动脉疾病

基于云的融合成像改善开窗支架腔内动脉瘤修复术中的手术指标

Cloud-based fusion imaging improves operative metrics during fenestrated endovascular aneurysm repair.
PubMed 文献 · J Vasc Surg · 2022-09-29

该回顾性研究比较了2013至2020年间191例开窗支架腔内动脉瘤修复术(FEVAR)中,使用Cydar EV智能地图引导(63例)与未使用(53例)的患者。结果显示Cydar EV组对比剂用量和辐射暴露显著降低,而透视时间和手术时间呈非显著下降趋势,术后主要不良事件和住院时间无显著差异。

要点

  • Cydar EV引导下FEVAR的碘对比剂用量显著低于无引导组(83±32 mL vs 105±44 mL,P=.005)。
  • Cydar EV组患者辐射暴露剂量面积乘积和累积空气比释动能均显著低于无引导组。
  • 两组术后主要不良事件、住院时间和ICU住院时间无显著差异。

主要发现

  • Cydar EV组平均透视时间66.2±33分钟 vs 无Cydar EV组69.3±28分钟(P=.598),差异无统计学意义。
  • Cydar EV组平均手术时间186±105分钟 vs 无Cydar EV组204.4±64分钟(P=.278),差异无统计学意义。
  • Cydar EV组碘对比剂用量83±32 mL vs 无Cydar EV组105±44 mL(P=.005),显著降低。
  • Cydar EV组剂量面积乘积630,990 mGy/cm2 vs 无Cydar EV组1,049,841 mGy/cm2(P<.001),显著降低。
  • Cydar EV组累积空气比释动能3084 mGy vs 无Cydar EV组4518 mGy(P=.02),显著降低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Endovascular treatment of complex aortic pathology has been associated with increases in procedural-related metrics, including the operative time and radiation exposure. Three-dimensional fusion imaging technology has decreased the radiation dose and iodinated contrast use during endovascular aneurysm repair. The aim of the present study was to report our institutional experience with the use of a cloud-based fusion imaging platform during fenestrated endovascular aneurysm repair (FEVAR). METHODS: A retrospective review of a prospectively maintained aortic database was performed to identify all patients who had undergone FEVAR with commercially available devices (Zenith Fenestrated; Cook Medical Inc, Bloomington, IN) between 2013 and 2020 and all endovascular aneurysm repairs performed using Cydar EV Intelligent Maps (Cydar Medical, Cambridge, UK). The Cydar EV cohort was reviewed further to select all FEVARs performed with overlay map guidance. The patient demographic, clinical, and procedure metrics were analyzed, with a comparative analysis of FEVAR performed without and with the Cydar EV imaging platform. Patients were excluded from comparative analysis if the data were incomplete in the dataset or they had a documented history of prior open or endovascular abdominal aortic aneurysm repair. RESULTS: During the 7-year study period, 191 FEVARs had been performed. The Cydar EV imaging platform was implemented in 2018 and used in 124 complex endovascular aneurysm repairs, including 69 consecutive FEVARs. A complete dataset was available for 137 FEVARs. With exclusion to select for de novo FEVAR, a comparative analysis was performed of 53 FEVAR without and 63 with Cydar EV imaging guidance. The cohorts were similar in patient demographics, medical comorbidities, and aortic aneurysm characteristics. No significant difference was noted between the two groups for major adverse postoperative events, length of stay, or length of intensive care unit stay. The use of Cydar EV resulted in nonsignificant decreases in the mean fluoroscopy time (69.3 ± 28 minutes vs 66.2 ± 33 minutes; P = .598) and operative time (204.4 ± 64 minutes vs 186 ± 105 minutes; P = .278). A statistically significant decrease was found in the iodinated contrast volume (105 ± 44 mL vs 83 ± 32 mL; P = .005), patient radiation exposure using the dose area product (1,049,841 mGy/cm2 vs 630,990 mGy/cm2; P < .001) and cumulative air kerma levels (4518 mGy vs 3084 mGy; P = .02) for patients undergoing FEVAR with Cydar EV guidance. CONCLUSIONS: At our aortic center, we have observed a trend toward shorter operative times and significant reductions in both iodinated contrast use and radiation exposure during FEVAR using the Cydar EV intelligent maps. Intelligent map guidance improved the efficiency of complex endovascular aneurysm repair, providing a safer intervention for both patient and practitioner.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Bailey CJ, Edwards JB, Giarelli M, et al. Cloud-based fusion imaging improves operative metrics during fenestrated endovascular aneurysm repair. J Vasc Surg. 2022. PMID: 36181994. doi:10.1016/j.jvs.2022.09.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。