Amplatzer血管塞联合Endologix AFX覆膜支架用于慢性B型主动脉夹层患者内脏入口封堵

Amplatzer Vascular Plug With Endologix AFX Lining for Visceral Re-Entry Closure in a Patient With Chronic Type B Aortic Dissection.
PubMed 文献 · J Endovasc Ther · 2022-10-27

本病例报告描述一名70岁女性慢性B型主动脉夹层患者,随访发现瘤囊增大,腹腔干开口处存在孤立残余破口。使用12 mm Amplatzer血管塞(AVP2)封堵后造影仍见假腔残余血流,随后置入Endologix AFX VELA近端覆膜支架覆盖血管塞膜,无内漏。结论认为血管塞联合Endologix AFX覆膜支架衬里可有效实现腹腔干开口处入口破口的完全封闭。

要点

  • 70岁女性慢性B型主动脉夹层瘤囊增大,腹腔干开口处孤立残余破口。
  • 12 mm AVP2封堵后造影仍见假腔残余血流,加用Endologix AFX VELA覆膜支架后无内漏。
  • 作者认为血管塞联合AFX覆膜支架衬里可有效封闭腹腔干开口处入口破口。

核心结论

  • 作者认为,血管塞联合Endologix AFX覆膜支架衬里可有效实现该患者腹腔干开口处入口破口的完全封闭。

研究设计与样本

  • 病例报告:一名70岁女性慢性B型主动脉夹层患者,已接受治疗,随访发现瘤囊增大。

主要发现

  • 造影显示腹腔干开口处存在孤立残余破口。
  • 置入12 mm AVP2封堵破口后,造影仍显示假腔残余血流。
  • 随后置入Endologix AFX VELA近端覆膜支架覆盖AVP膜,未见内漏。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To demonstrate the efficacy of a combination of Amplatzer vascular plug (AVP2) and Endologix AFX for a visceral entry closure. CASE REPORT: A 70-year-old woman with treated chronic type B aortic dissection was seen to have sac enlargement. An isolated residual tear was observed at the origin of the celiac artery. A 12 mm AVP2 was successfully deployed for the entry closure. Angiography after the plug deployment still demonstrated residual flow to the false lumen. Hence, an Endologix AFX VELA proximal endograft was deployed, covering the AVP membrane and leaving no endoleak. CONCLUSION: Deployment of a vascular plug with Endologix AFX lining was efficacious for securing complete closure of an entry tear at the origin of the celiac artery in our patient. CLINICAL IMPACT: Vascular plugs are reported to be effective for closing small entries, although their effectiveness is limited when the entry site is not located on the flat intima, or in a high-flow situation. In the presented case, an isolated entry tear at the origin of the celiac artery was successfully closed with a vascular plug following Endologix AFX stent-graft lining of the true lumen.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Watanabe S, Saito Y, Murata K, et al. Amplatzer Vascular Plug With Endologix AFX Lining for Visceral Re-Entry Closure in a Patient With Chronic Type B Aortic Dissection. J Endovasc Ther. 2022. PMID: 36300538. doi:10.1177/15266028221131450

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。