文献速递颈动脉与弓上血管

颈动脉内膜剥脱术围手术期脑与血流动力学监测方法的系统综述与Meta分析

A Systematic Review and Meta-Analysis on Perioperative Cerebral and Hemodynamic Monitoring Methods during Carotid Endarterectomy.
PubMed 文献 · Ann Vasc Surg · 2022-09-10

该系统综述与Meta分析比较颈动脉内膜剥脱术围手术期不同脑与血流动力学监测策略的结局,检索MEDLINE、EMBASE、CINAHL和Cochrane CENTRAL数据库,纳入17项随机对照试验、3项前瞻性观察研究和7项注册研究,共236,983例患者。汇总30天卒中率为1.8%(95%CI 1.4-2.2%),不同监测与转流策略间无显著差异,但作者认为不推荐常规不转流。

要点

  • 汇总30天卒中率为1.8%(95%CI 1.4-2.2%),随机对照试验为2.7%(95%CI 1.6-3.7%),注册研究为1.3%(95%CI 0.8-1.8%)。
  • 2000年前卒中风险为3.7%,2000年后降至1.6%。
  • 不同监测与转流策略间无显著差异,但随机对照试验常规不转流组观察到卒中率较高趋势。

核心结论

  • 不同转流与监测策略间未发现显著差异,但作者认为不推荐常规不转流。
  • 现有数据太有限,选择性转流时无法优选某一种神经监测方法。

研究设计与样本

  • 系统综述与Meta分析,遵循PRISMA指南,并在国际前瞻性系统综述注册库注册(CRD42021241891)。
  • 检索MEDLINE、EMBASE、CINAHL和Cochrane CENTRAL数据库,共识别3,460篇文章。
  • 纳入17项随机对照试验、3项前瞻性观察研究和7项注册研究,共报告236,983例患者。
  • 采用GRADE方法描述研究的方法学质量和证据确定性。

主要发现

  • 总体汇总30天卒中率为1.8%(95%CI 1.4-2.2%),范围0至12.6%。
  • 随机对照试验汇总30天卒中率为2.7%(95%CI 1.6-3.7%),注册研究为1.3%(95%CI 0.8-1.8%)。
  • 总体卒中风险从2000年前的3.7%降至2000年后的1.6%。
  • 不同监测与转流策略间未发现显著差异,但随机对照试验常规不转流组观察到卒中率较高趋势。
  • 总体30天死亡率、心肌梗死率和神经损伤率分别为0.6%(95%CI 0.4-0.8)、0.8%(95%CI 0.6-1.0)和1.3%(95%CI 0.4-2.2)。

关键数值与推荐

  • 主要结局为30天卒中率。
  • 次要结局包括30天同侧卒中、30天死亡率、转流率和并发症率。

临床怎么用

  • 作者认为不推荐常规不转流。
  • 作者认为现有数据太有限,选择性转流时无法优选某一种神经监测方法。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To compare outcomes between different strategies of perioperative cerebral and hemodynamic monitoring during carotid endarterectomy. DATA SOURCES: MEDLINE, EMBASE, CINAHL, and Cochrane CENTRAL databases were searched. METHODS: This review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and prospectively registered in the international prospective register of systematic reviews (CRD42021241891). The Grading of Recommendations, Assessment, Development and Evaluation approach was used to describe the methodological quality of the studies and certainty of the evidence. The primary outcome was 30-day stroke rate. Secondary outcomes measures are 30-day ipsilateral stroke, 30-day mortality, shunt rate, and complication rates. RESULTS: The search identified 3,460 articles. Seventeen randomized controlled trials (RCTs), three prospective observational studies and seven registries were included, reporting on 236,983 patients. The overall pooled 30-day stroke rate is 1.8% (95% CI 1.4-2.2%), ranging from 0 to 12.6%. In RCT's the pooled 30-day stroke rate is 2.7% (95% CI 1.6-3.7%) compared to 1.3% (95% CI 0.8-1.8%) in the registries. The overall stroke risk decreased from 3.7% before the year 2000 to 1.6% after 2000. No significant differences could be identified between different monitoring and shunting strategies, although a trend to higher stroke rates in routine no shunting arms of RCTs was observed. Overall, 30-day mortality, myocardial infarction and nerve injury rates are 0.6% (95% CI 0.4-0.8), 0.8% (95% CI 0.6-1.0) and 1.3% (95% CI 0.4-2.2), respectively. CONCLUSIONS: No significant differences between the compared shunting and monitoring strategies are found. However, routine no shunting is not recommended. The available data are too limited to prefer 1 method of neuromonitoring over another method when selective shunting is applied.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Vuurberg NE, Post ICJH, Keller BPJA, et al. A Systematic Review and Meta-Analysis on Perioperative Cerebral and Hemodynamic Monitoring Methods during Carotid Endarterectomy. Ann Vasc Surg. 2022. PMID: 36100123. doi:10.1016/j.avsg.2022.08.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。