首次术后CT血管造影的最短贴附长度可识别腹主动脉瘤腔内修复术后迟发Ia型内漏风险患者
本研究从连续数据库选取首次术后CTA后发生迟发Ia型内漏(T1aEL)的患者,与无并发症对照匹配,在首次术后CTA上测定内移植物贴附与位置(含最短贴附长度SAL)。结果显示T1aEL组中位SAL为11.6 mm vs 对照组20.7 mm(p=0.002),SAL<10 mm(OR 9.63,95%CI 1.60-57.99)与较大瘤颈直径(OR 1.80,95%CI 1.26-2.57)为迟发T1aEL的独立预测因素。
要点
- 首次术后CTA测得SAL<10 mm者迟发Ia型内漏风险显著升高(OR 9.63,95%CI 1.60-57.99)。
- 术前瘤颈直径较大亦为迟发Ia型内漏的独立预测因素(OR 1.80,95%CI 1.26-2.57)。
- T1aEL组中位SAL 11.6 mm vs 对照组20.7 mm(p=0.002)。
核心结论
- 术前瘤颈直径与EVAR后首次术后CTA上的SAL是迟发T1aEL的重要预测因素。
- SAL<10 mm的患者发生迟发T1aEL的风险显著更高。
- 未来研究应确定这些患者在实际T1aEL出现前能否从再干预中获益。
研究设计与样本
- 从连续数据库选取首次术后CTA后发生T1aEL的患者,并与无并发症对照匹配。
- 在首次术后CTA上测定内移植物贴附与位置,包括最短贴附长度(SAL)。
- 共纳入32例迟发T1aEL患者,匹配32例无并发症对照。
主要发现
- T1aEL组中位随访62.0(IQR 36.8,83.5)个月 vs 对照组47.5(IQR 34.0,79.3)个月;p=0.265。
- T1aEL组中位术前瘤颈直径26.6(IQR 24.9,29.6)mm vs 对照组23.4(IQR 22.5,25.3)mm;p<0.001。
- T1aEL组中位SAL 11.6(IQR 4.3,20.5)mm vs 对照组20.7(IQR 13.1,24.9)mm;p=0.002。
- 首次术后CTA上SAL<10 mm(OR 9.63,95%CI 1.60-57.99)与较大瘤颈直径(OR 1.80,95%CI 1.26-2.57)为迟发T1aEL的独立预测因素。
关键数值与推荐
- 首次术后CTA上SAL<10 mm者迟发T1aEL风险升高(OR 9.63,95%CI 1.60-57.99)。
- 术前瘤颈直径每增加一定幅度,迟发T1aEL风险升高(OR 1.80,95%CI 1.26-2.57)。
- 目前指南建议对密封长度<10 mm的患者重复CTA影像监测。
临床怎么用
- 首次术后CTA可测定SAL,用于识别迟发T1aEL高风险患者。
- SAL<10 mm的患者风险高,目前指南建议重复CTA影像监测。
- 作者认为未来研究应确定这些患者在T1aEL出现前能否从再干预中获益。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Imaging surveillance following endovascular aneurysm repair (EVAR) is strictly recommended. This study investigates the value of endograft apposition and position relative to the aortic neck on the first postoperative computed tomography angiography (CTA) in determining patients at risk for a late type Ia endoleak (T1aEL). MATERIALS AND METHODS: Patients with a T1aEL after the first postoperative CTA were selected from a consecutive database and matched with uncomplicated controls. Endograft apposition and position, including the shortest apposition length (SAL), were determined on the first postoperative CTA. The SAL is the shortest distance between the proximal endograft fabric and the first slice where circumferential apposition with the aortic wall is lost. Differences in endograft apposition at the first postoperative CTA were compared between groups. Logistic regression analysis identified independent predictors for late T1aEL. RESULTS: A total of 32 patients with a late T1aEL were included and matched with 32 uncomplicated controls. Median follow-up after primary EVAR was 62.0 (interquartile range [IQR]: 36.8, 83.5) months in the T1aEL group compared with 47.5 (IQR: 34.0, 79.3) months in the control group; p=0.265. Median preoperative neck diameter was significantly larger in the T1aEL group than in the control group (26.6 [IQR: 24.9, 29.6] mm versus 23.4 [IQR: 22.5, 25.3] mm); p<0.001. Patients in the T1aEL group had a median SAL of 11.6 (IQR: 4.3, 20.5) mm compared with 20.7 (IQR: 13.1, 24.9) mm in the control group; p=0.002. SAL <10mm on the first postoperative CTA (odds ratio [OR]: 9.63, 95% confidence interval [CI]: 1.60-57.99) and larger neck diameter (OR: 1.80, 95% CI: 1.26-2.57) were independent predictors for developing a late T1aEL. CONCLUSION: Preoperative neck diameter and SAL on the first postoperative CTA following EVAR are important predictors for the development of a late T1aEL. Patients with a SAL of <10mm had a significantly higher risk of developing a late T1aEL. Future research should determine whether these patients would benefit from reintervention before an actual T1aEL is present. CLINICAL IMPACT: Understanding the mechanisms of endovascular aneurysm repair failure is essential to further enhance clinical outcomes. Adequate proximal sealing is necessary to foster freedom from type 1a endoleak. This study demonstrates that the shortest apposition length (SAL) at the first postoperative computed tomography angiography (CTA) is able to identify patients at risk for a late type 1a endoleak. Especially patients with a SAL <10mm are at high risk. Currently, the guidelines advice repeated imaging with CTA in patients with a seal <10mm. Future research should determine whether these patients would benefit from re-intervention before an actual type 1a endoleak is present.
引用
- Geraedts ACM, Zuidema R, Schuurmann RCL, et al. Shortest Apposition Length at the First Postoperative Computed Tomography Angiography Identifies Patients at Risk for Developing a Late Type Ia Endoleak After Endovascular Aneurysm Repair. J Endovasc Ther. 2022. PMID: 36113063. doi:10.1177/15266028221120514
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。