文献速递主动脉疾病

对分支和开窗医师改良腔内移植物上肢入路全经股动脉途径的单中心回顾

A Single Center Review of a Total Transfemoral Approach to Upper Extremity Access in Branched and Fenestrated Physician Modified Endografts.
PubMed 文献 · Ann Vasc Surg · 2022-07-06

单中心2015至2020年56例医师改良腔内移植物修复肾旁或IV型胸腹主动脉瘤及更复杂胸腹主动脉瘤患者,按分支血管入路分为全经股动脉组27例与腋动脉或复合入路组29例,腋动脉或复合入路组手术时间、辐射剂量、透视时间和出血量均高于全经股动脉组,30天死亡率及主要不良事件包括卒中无显著差异。

要点

  • 腋动脉或复合入路组较全经股动脉组平均手术时间延长(418 vs 246 min,P<0.001)。
  • 腋动脉或复合入路组较全经股动脉组辐射剂量(2755 vs 1740 mGy,P=0.03)和透视时间(108 vs 74 min,P=0.01)增加。
  • 两组30天死亡率及主要不良事件包括卒中无显著差异。

核心结论

  • 与腋动脉或复合入路相比,复杂腔内主动脉瘤修复采用全经股动脉入路可减少手术时间、辐射剂量和透视时间,30天死亡率或主要不良事件无显著差异。
  • 作者认为治疗复杂动脉瘤时提高效率对减少患者和术者并发症很重要。

研究设计与样本

  • 单中心回顾性研究,纳入2015至2020年接受医师改良腔内移植物修复的患者。
  • 共56例患者,41例为肾旁或IV型胸腹主动脉瘤,15例为更复杂胸腹主动脉瘤。
  • 按分支血管入路分为全经股动脉组27例(48%)与腋动脉或复合(腋动脉加股动脉)入路组29例(52%)。
  • 主要结局为手术时间、辐射暴露、透视时间、造影剂和出血量;次要结局为30天死亡率和主要不良事件。
  • 采用线性回归模型评估入路类型与主要结局的关联。

主要发现

  • 腋动脉或复合入路组较全经股动脉组平均手术时间增加(418 vs 246 min,P<0.001)。
  • 腋动脉或复合入路组较全经股动脉组辐射暴露增加(2755 vs 1740 mGy,P=0.03)。
  • 腋动脉或复合入路组较全经股动脉组透视时间增加(108 vs 74 min,P=0.01)。
  • 腋动脉或复合入路组较全经股动脉组出血量增加(579 vs 202 cc,P=0.002)。
  • 30天死亡率或主要不良事件包括卒中无显著差异。

临床怎么用

  • 作者认为,在治疗复杂动脉瘤时,采用全经股动脉入路而非腋动脉或复合入路可减少手术时间、辐射暴露和透视时间,且30天死亡率或主要不良事件无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Aortic aneurysms are normally treated by an endovascular approach. Due to the lack of devices and increasing experience, there is a growing number of complex aneurysms undergoing repair by physician modified endografts (PMEGs). Previously, our practice was to target visceral vessels exclusively through upper extremity access. We have since then shifted to an all transfemoral approach when possible. This study aims to show the operative benefits of transfemoral only approaches. METHODS: Patients who underwent a PMEG at a tertiary center between 2015 and 2020 were included. Patients were stratified into 2 groups based on branched vessel approach-transfemoral only versus axillary or composite (axillary and femoral). Forty-one patients had a pararenal or type IV thoracoabdominal aortic aneurysm (TAAA) and 15 patients had more complex TAAA. Primary outcomes were operative time, radiation exposure, fluoroscopy time, contrast, and blood loss. Secondary outcomes were 30-day mortality and major adverse events. Linear regression models were used to evaluate the association between approach type and the main outcomes. RESULTS: Fifty-six patients were included with 48% (n = 27) in the transfemoral group and 52% (n = 29) in the axillary/composite group. Baseline characteristics were similar between the groups. Intraoperative outcomes revealed significant increase in the average operative time (418 vs. 246 min, P < 0.001), in radiation exposure (2,755 vs. 1,740 mGy, P = 0.03), in fluoroscopy time (108 vs. 74 min, P = 0.01) and in blood loss (579 vs. 202 cc, P = 0.002) in the axillary/composite group compared to the transfemoral group. There was no significant difference in 30-day mortality or major adverse events including stroke. CONCLUSIONS: This study shows a transfemoral approach to complex endovascular aortic aneurysm repair as opposed to axillary/composite approach has decreased operative time, radiation exposure, and fluoroscopy time and no significant differences in 30-day mortality or major adverse events. When treating complex aneurysms, improving efficiency is important to minimize morbidity to patients and operators.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Patel RJ, Mathlouthi A, Al-Nouri O, et al. A Single Center Review of a Total Transfemoral Approach to Upper Extremity Access in Branched and Fenestrated Physician Modified Endografts. Ann Vasc Surg. 2022. PMID: 35809740. doi:10.1016/j.avsg.2022.05.041

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。