文献速递主动脉疾病

近端锥形支架联合远端限制性支架行胸主动脉腔内修复术治疗高锥度B型主动脉夹层

Thoracic Endovascular Aortic Repair of Highly Tapered Type B Aortic Dissection with Proximal Tapered Stent Grafts and Distal Restrictive Stent Grafts.
PubMed 文献 · Ann Vasc Surg · 2022-05-18

34例高锥度B型主动脉夹层患者随机分为限制性TEVAR组(16例)和标准TEVAR组(18例),限制性TEVAR采用近端锥形支架联合远端限制性支架。结果显示限制性TEVAR组支架锥度与降主动脉匹配、支架覆盖更长,术后6、12、24个月降主动脉完全重塑率均优于标准TEVAR组,两组累积生存率无差异。

要点

  • 限制性TEVAR组支架锥度与降主动脉匹配(24.7±3.4% vs 27.3±4.2%,P=0.068),标准TEVAR组不匹配(13.5±3.3% vs 30.5±9.6%,P<0.001)。
  • 限制性TEVAR组支架覆盖长度长于标准TEVAR组(220.4±21.1 mm vs 175.3±17.8 mm,P<0.001)。
  • 限制性TEVAR组术后6、12、24个月降主动脉完全重塑率均优于标准TEVAR组,两组累积生存率无差异(P=0.166)。

核心结论

  • 近端锥形支架联合远端限制性支架的限制性TEVAR可匹配高锥度B型主动脉夹层的锥度、延长支架覆盖长度,并较标准TEVAR带来更好的降主动脉重塑。

研究设计与样本

  • 随机对照研究,纳入34例高锥度B型主动脉夹层患者,随机分为限制性TEVAR组(16例)和标准TEVAR组(18例)。
  • 高锥度B型主动脉夹层定义为近端和远端胸主动脉锚定区真腔最大直径锥度大于8 mm或锥度比大于20%。
  • 限制性TEVAR组行近端锥形支架联合远端限制性支架,以匹配降主动脉锥度并延长支架覆盖长度;标准TEVAR组仅植入近端锥形支架。
  • 通过随访期间CT血管造影评估主动脉重塑。

主要发现

  • 限制性TEVAR组支架锥度与降主动脉匹配(24.7±3.4% vs 27.3±4.2%,P=0.068),标准TEVAR组不匹配(13.5±3.3% vs 30.5±9.6%,P<0.001)。
  • 限制性TEVAR组支架覆盖长度长于标准TEVAR组(220.4±21.1 mm vs 175.3±17.8 mm,P<0.001)。
  • 限制性TEVAR组术后6个月降主动脉完全重塑率高于标准TEVAR组(40% vs 5.6%,P=0.03)。
  • 限制性TEVAR组术后12个月降主动脉完全重塑率高于标准TEVAR组(60% vs 16.7%,P=0.027)。
  • 限制性TEVAR组术后24个月降主动脉完全重塑率高于标准TEVAR组(78.6% vs 41.2%,P=0.036);两组累积生存率无差异(P=0.166)。

关键数值与推荐

  • 高锥度B型主动脉夹层定义:近端和远端胸主动脉锚定区真腔最大直径锥度大于8 mm或锥度比大于20%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study evaluated aortic remodeling in highly tapered type B aortic dissection (TBAD) patients who underwent thoracic endovascular aortic repair (TEVAR) with a proximal tapered stent graft plus a distal restrictive stent graft to maximize thoracic coverage while avoiding distal excessive oversizing. METHODS: Thirty-four patients presenting with highly tapered TABD were randomized to restricted TEVAR (r-TEVAR) and standard TEVAR groups. Highly tapered TBAD was defined as the maximal diameter of the true lumen at proximal and distal thoracic aorta landing zone tapers greater than 8 mm or taper ratio greater than 20%. Patients in the r-TEVAR group underwent proximal tapered stent grafts plus distal restrictive stent grafts, to match the taper ratio of the descending thoracic aorta (DTA) and extend the length of stent coverage. Patients in the standard TEVAR group underwent proximal tapered stent grafts implantation without distal restrictive stent grafts. Aortic remodeling was estimated by computed tomography angiography (CTA) during the follow-up. RESULTS: In total, 16 patients underwent r-TEVAR, and 18 patients underwent standard TEVAR. The taper ratio of the stent graft matched the DTA in the r-TEVAR group (24.7 ± 3.4% vs. 27.3 ± 4.2%, P = 0.068), but did not match that in the standard TEVAR group (13.5 ± 3.3% vs. 30.5 ± 9.6%, P < 0.001). The length of stent graft coverage in the r-TEVAR group was longer than that in the standard TEVAR group (220.4 ± 21.1 mm vs. 175.3 ± 17.8 mm, P < 0.001). Compared with the standard TEVAR group, the r-TEVAR group had better complete remodeling of the DTA at 6 months (40% vs. 5.6%, P = 0.03), 12 months (60% vs. 16.7%, P = 0.027), and 24 months (78.6% vs. 41.2%, P = 0.036) after the operation. There was no difference in the cumulative survival rate between the r-TEVAR and standard TEVAR groups (P = 0.166). CONCLUSIONS: The r-TEVAR with overlapping proximal tapered stent grafts and distal restrictive stent grafts can match the taper of highly tapered TABD, extend the length of stent graft coverage, and lead to better remodeling of the DTA than standard TEVAR.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Niu L, Bao X, Yu W, et al. Thoracic Endovascular Aortic Repair of Highly Tapered Type B Aortic Dissection with Proximal Tapered Stent Grafts and Distal Restrictive Stent Grafts. Ann Vasc Surg. 2022. PMID: 35595209. doi:10.1016/j.avsg.2022.05.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。