腹主动脉腔内修复术前置入主动脉袖套预防II型内漏的早中期结果
回顾性单中心研究纳入9例腹主动脉瘤患者,在EVAR主体置入前使用主动脉袖套预防II型内漏,技术成功率100%,无围手术期及术后并发症、死亡或再干预,6例无内漏,3例袖套覆盖范围外腰动脉来源II型内漏,随访期间5例瘤囊缩小、3例稳定、1例短暂性瘤囊扩张但1.5年后无变化。
要点
- EVAR术前置入主动脉袖套预防II型内漏,技术成功率100%。
- 术后CT示6例无内漏,3例为袖套覆盖范围外腰动脉来源的II型内漏。
- 随访期间5例瘤囊缩小、3例稳定、1例短暂性扩张但1.5年后无变化。
核心结论
- 作者认为主动脉袖套技术是EVAR中预防II型内漏的一种有利的腔内方法,单个主动脉袖套可简单可靠地闭塞从瘤囊发出的分支动脉。
研究设计与样本
- 回顾性单中心研究,分析9例腹主动脉瘤患者(平均年龄79岁,范围69-88岁;8例男性),均接受使用主动脉袖套预防II型内漏的EVAR。
主要发现
- 技术成功率为100%,无术中或术后并发症,无死亡或再干预发生。
- 术后CT示6例无内漏,3例存在主动脉袖套置入范围外的腰动脉来源II型内漏,但任何患者袖套置入范围内的动脉均未观察到II型内漏。
- 成功闭塞动脉的平均数量为4.2条(范围2-8条)。
- 所有患者随访均超过6个月(平均18.6个月,范围6-36个月);随访期间5例瘤囊缩小,3例瘤体大小稳定,仅1例出现短暂性瘤囊扩张,但1.5年后该扩张无变化。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Postoperatively persistent type II endoleaks (T2ELs) in abdominal endovascular aneurysm repair (EVAR) are known risk factors for long-term aneurysm enlargement. Therefore, various measures have been proposed to prevent T2ELs. Notably, the Kilt technique, which can be used in patients with dumbbell-shaped morphology, employs an aortic cuff deployed in the distal seal zone before the main body. Although previous studies have successfully applied this technique for preventing T2ELs, the mid- and long-term outcomes remain unclear. This study aimed to report the early- to mid-term outcomes in cases where an aortic cuff technique was used to prevent T2ELs. MATERIALS AND METHODS: This retrospective single-center study analyzed 9 patients (mean age, 79 years; range, 69-88 years; 8 men) with abdominal aortic aneurysms. All patients underwent EVAR using an aortic cuff to prevent T2ELs. The primary end points were technical success (successful deployment) and clinical success (no T2ELs). Secondary end points included morbidity, reintervention, and aortic remodeling during follow-up. RESULTS: The technical success rate was 100%. There were no intraprocedural or postoperative complications. No deaths or reinterventions occurred. Postoperative computed tomography showed no endoleaks in 6 patients, while T2ELs from the lumbar artery outside the aortic cuff deployment range were noted in 3 patients. However, no T2ELs were observed in the artery in the aortic cuff deployment range in any patient. The average number of successfully occluded arteries was 4.2 (range, 2-8). All patients had follow-up >6 (mean, 18.6; range, 6-36) months. Aneurysm sac shrinkage occurred in 5 patients during the follow-up period, whereas aneurysm size was stable in 3 patients. In contrast, only 1 patient showed transient dilation of the aneurysm sac enlargement; however, this dilation remained unchanged even after 1.5 years. CONCLUSION: The aortic cuff technique is a favorable endovascular method for preventing T2ELs in EVAR. The present study showed that a single aortic cuff could easily and reliably occlude arteries branched from the aneurysm sac.
引用
- Mikami T, Kawaharada N, Kamada T, et al. Early- and Mid-Term Results of Abdominal Endovascular Aneurysm Repair Using an Aortic Cuff Prior to the Main Body to Prevent Type II Endoleaks. J Endovasc Ther. 2022. PMID: 35416069. doi:10.1177/15266028221090446
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。