文献速递主动脉疾病

DeBakey I型夹层杂交主动脉弓修复中应用术中数字减影血管造影处理左锁骨下动脉

Use of On-Site Digital Subtraction Angiography for Left Subclavian Artery Management During Hybrid Aortic Arch Repair in DeBakey I Dissection.
PubMed 文献 · J Endovasc Ther · 2022-01-10

本病例报告报道一名61岁DeBakey I型主动脉夹层患者,在中等低温循环停搏(26°C)和选择性脑灌注下使用Thoraflex-Hybrid假体于2区锚定行冻结象鼻技术,覆盖左锁骨下动脉开口且未额外行左锁骨下动脉去分支。术中通过左锁骨下动脉反流分析联合术中数字减影血管造影(ARTIS Pheno syngo软件)证实左锁骨下动脉灌注充分,术后无神经功能障碍或缺血,7天后血管造影CT显示左锁骨下动脉生理性灌注及近端降主动脉假腔血栓性闭塞。作者认为血管造影引导下处理复杂DeBakey I型夹层及困难解剖可能简化2区远端吻合口近端化而不需额外左锁骨下动脉去分支。

要点

  • 61岁DeBakey I型夹层患者在中等低温循环停搏(26°C)和选择性脑灌注下使用Thoraflex-Hybrid假体于2区锚定行冻结象鼻技术,覆盖左锁骨下动脉开口且未额外去分支。
  • 术中通过左锁骨下动脉反流分析联合术中数字减影血管造影(ARTIS Pheno syngo软件)证实左锁骨下动脉灌注充分。
  • 术后无神经功能障碍或缺血,7天后血管造影CT显示左锁骨下动脉生理性灌注及近端降主动脉假腔血栓性闭塞。

核心结论

  • 作者认为,对复杂DeBakey I型夹层及困难解剖患者采用血管造影引导下处理可能简化冻结象鼻技术中2区远端吻合口近端化,即使不额外行左锁骨下动脉去分支。

研究设计与样本

  • 单例病例报告:61岁DeBakey I型主动脉夹层患者,行冻结象鼻技术杂交主动脉弓修复,中等低温循环停搏(26°C)和选择性脑灌注,Thoraflex-Hybrid(Vascutek Terumo)假体锚定于2区,覆盖左锁骨下动脉开口,未额外行左锁骨下动脉去分支。

主要发现

  • 术中采用选择性脑灌注期间左锁骨下动脉反流分析联合术中数字减影血管造影(ARTIS Pheno syngo软件)证实左锁骨下动脉灌注充分。
  • 术后病程中未发生神经功能障碍或缺血。
  • 术后7天血管造影CT显示左锁骨下动脉生理性灌注,随后近端降主动脉假腔血栓性闭塞。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: A hybrid aortic repair using the frozen elephant trunk (FET) technique with an open distal anastomosis in zone 2 and debranching of the left subclavian artery (LSA) has been demonstrated to be favorable and safe. Although a transposition of the LSA reduces the risk of cerebellar or medullar ischemia, this may be challenging in difficult LSA anatomies. CASE REPORT: We present the case of a 61-year old patient with DeBakey I aortic dissection, treated with FET in moderate hypothermic circulatory arrest (26°C) and selective cerebral perfusion using a Thoraflex-Hybrid (Vascutek Terumo) prosthesis anchored in zone 2, with overstenting of the LSA orifice and no additional LSA debranching. Sufficient perfusion of the LSA was proved intraoperatively using LSA backflow analysis during selective cerebral perfusion in combination with on-site digital subtraction angiography (ARTIS Pheno syngo software). No neurologic dysfunction or ischemia occurred in the postoperative course. An angiographic computed tomography revealed physiologic LSA perfusion, with subsequent thrombotic occlusion of the false lumen in the proximal descending aorta after 7 days. CONCLUSION: Using an angiography-guided management in patients with complex DeBakey I dissection and difficult anatomy may simplify a proximalization of the distal anastomosis in zone 2 for FET, even without an additional LSA debranching.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Haldenwang PL, Elghannam M, Buchwald D, et al. Use of On-Site Digital Subtraction Angiography for Left Subclavian Artery Management During Hybrid Aortic Arch Repair in DeBakey I Dissection. J Endovasc Ther. 2022. PMID: 35012388. doi:10.1177/15266028211068759

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。