文献速递血液透析通路

自体桡动脉头静脉与肱动脉头静脉动静脉瘘手术基于经时血流计评估的结局:一项回顾性研究

Outcomes of Autogenous Radiocephalic Versus Brachiocephalic Arteriovenous Fistula Surgery Based on Transit-Time Flowmeter Assessment: A Retrospective Study.
PubMed 文献 · Ann Vasc Surg · 2021-12-20

该回顾性研究纳入2017至2019年间194例匹配患者,比较自体肱动脉头静脉动静脉瘘(BC-AVF)与桡动脉头静脉动静脉瘘(RC-AVF)的结局。BC-AVF组术中最大流量更高(492.5 ± 186.9 mL/min vs 307.3 ± 113.0 mL/min),初级通畅率更高(88.7% vs 62.9%),中位观察19.4个月期间未增加AVF相关并发症风险。

要点

  • BC-AVF组术中最大流量为492.5 ± 186.9 mL/min,高于RC-AVF组的307.3 ± 113.0 mL/min(P < 0.001)。
  • BC-AVF组初级通畅率为88.7%,高于RC-AVF组的62.9%(P < 0.001)。
  • 中位观察19.4个月期间,BC-AVF组出现3例头静脉弓狭窄,未观察到动脉窃血综合征。

核心结论

  • 在中位19个月的观察期内,BC-AVF具有良好的血液透析特性,且未增加AVF相关并发症风险。
  • 采用包括术前锻炼、术中流量评估以保证足够流量、术后锻炼和药物治疗的多模式方法,BC-AVF未出现高流量相关并发症。

研究设计与样本

  • 回顾性研究,纳入2017至2019年间要求行自体BC-AVF或RC-AVF手术的194例匹配患者,每组97例。
  • 所有患者严格遵循本科室AVF手术围手术期管理方案,包括血管状态监测、伴或不伴止血带的锻炼、术中流量评估以及抗血小板和抗凝药物。
  • AVF功能和患者状态数据来自电子病历,最终评估通过2020年10月门诊就诊或电话进行。

主要发现

  • BC-AVF组计划吻合处的动脉和静脉尺寸大于RC-AVF组(P < 0.001)。
  • BC-AVF组术中最大流量均值为492.5 ± 186.9 mL/min,高于RC-AVF组的307.3 ± 113.0 mL/min(P < 0.001)。
  • 同时评估的平均搏动指数在BC-AVF组为0.5 ± 0.2,在RC-AVF组为0.6 ± 0.2(P < 0.001)。
  • 中位观察时长为19.4个月(11.0‒31.3个月),BC-AVF组初级通畅率为88.7%,高于RC-AVF组的62.9%(P < 0.001)。
  • BC-AVF组观察到3例头静脉弓狭窄,观察期间未观察到动脉窃血综合征;BC-AVF组和RC-AVF组死亡率分别为14.4%和9.3%(P = 0.267),死因组间无显著差异;RC-AVF相对于BC-AVF的死亡风险估计风险比为0.47(95% CI,0.19‒1.17,P = 0.106)。

临床怎么用

  • 作者认为,采用包括术前锻炼、术中流量评估以保证足够流量、术后锻炼和药物治疗的多模式方法,BC-AVF未出现高流量相关并发症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Despite the better operative results of autogenous brachiocephalic arteriovenous fistula (BC-AVF), it is considered secondary to autogenous radiocephalic AVF (RC-AVF) failure. Here we compared the results of our multidisciplinary management protocol of BC-AVF versus RC-AVF. METHODS: A total of 194 matched patients who requested autogenous BC-AVF or RC-AVF surgery between 2017 and 2019 were included in this retrospective study. All patients strictly adhered to our departmental perioperative management protocol for AVF surgery, including vessel status monitoring, exercise with or without a tourniquet, intraoperative flow assessment, and antiplatelet and anticoagulant medications. AVF function and patient status data were acquired from the electronic medical records, and the final evaluation was made via outpatient department visit or phone call in October 2020. RESULTS: Patients who underwent elective BC-AVF or RC-AVF (n = 97 each) were included. The patient groups had similar preoperative clinical characteristics. Artery and vein sizes at the planned anastomosis site were larger in the BC-AVF group (P < 0.001). The mean intraoperative maximal flow rate was higher in the BC-AVF group (492.5 ± 186.9 mL/min) than in the RC-AVF group (307.3 ± 113.0 mL/min, P < 0.001). The simultaneously evaluated mean pulsatility index was 0.5 ± 0.2 in the BC-AVF group and 0.6 ± 0.2 in the RC-AVF group (P < 0.001). The median observation duration was 19.4 months (11.0‒31.3 months). The primary patency rate was higher in the BC-AVF group (88.7%) than in the RC-AVF group (62.9%, P < 0.001). Patency duration was similar between groups, and the primary patency maintenance duration was longer in the BC-AVF group. Three cases of cephalic arch stenosis were observed in the BC-AVF group, while no cases of arterial steal syndrome were observed during the indexed observation period. Mortality rates were 14.4% and 9.3% in the BC-AVF and RC-AVF groups, respectively (P = 0.267), and the cause of death did not differ significantly between groups. For mortality, the estimated hazard ratio of RC-AVF over BC-AVF was 0.47 (95% CI, 0.19‒1.17, P = 0.106) during the observation period. CONCLUSION: BC-AVF had good characteristics for hemodialysis without an increased risk of AVF related complications during a median 19-month observation period. BC-AVF did not feature high flow-related complications with the multimodal approach, including preoperative exercise, intraoperative flow assessment to guarantee an adequate flow rate, postoperative exercise, and medications.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Ryu YG, Lee DK. Outcomes of Autogenous Radiocephalic Versus Brachiocephalic Arteriovenous Fistula Surgery Based on Transit-Time Flowmeter Assessment: A Retrospective Study. Ann Vasc Surg. 2021. PMID: 34936890. doi:10.1016/j.avsg.2021.12.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。