文献速递颈动脉与弓上血管

血管内超声(IVUS)在颈动脉介入治疗中的临床价值:系统综述与Meta分析

Clinical Utility of Intravascular Ultrasound (IVUS) in Carotid Artery Interventions: A Systematic Review and Meta-analysis.
PubMed 文献 · J Endovasc Ther · 2021-12-27

该系统综述与Meta分析纳入截至2021年2月的英文文献,共29项研究、2015例患者,评估IVUS在颈动脉支架置入术中的临床价值。结果显示IVUS术后卒中/短暂性脑缺血发作汇总患病率为4%(95%CI 3%-5%),无症状卒中为46%(95%CI 31%-62%);IVUS较血管造影检出更多斑块突出(396例中33例 vs 396例中11例),并改变支架类型或尺寸(48例中8例)。作者认为IVUS在支架选择上优于CT/MR血管造影,但需大规模随机对照研究预测其临床结局作用。

要点

  • IVUS术后卒中/短暂性脑缺血发作汇总患病率为4%(95%CI 3%-5%)。
  • IVUS术后无症状卒中汇总患病率为46%(95%CI 31%-62%)。
  • IVUS较血管造影检出更多斑块突出(396例中33例 vs 396例中11例)。

核心结论

  • 该系统综述与Meta分析显示,IVUS在颈动脉支架置入术中较CT/MR血管造影更有利于支架选择,纳入研究偏倚风险低至中等。
  • 作者认为需要大规模、最好是随机对照的研究来预测IVUS在决定临床结局方面的作用。

研究设计与样本

  • 系统综述与Meta分析,检索截至2021年2月的英文文献。
  • 纳入报告IVUS参数与发现以及与其他影像模态比较的研究。
  • 共纳入29项研究、2015例患者;对11项研究、1566例患者进行比例Meta分析。
  • 统计分析使用R版本3.6.2。

主要发现

  • 9项研究中,IVUS术后卒中/短暂性脑缺血发作汇总患病率为4%(95%CI 3%-5%)。
  • 4项研究中,IVUS术后无症状卒中汇总患病率为46%(95%CI 31%-62%)。
  • 2项研究报告IVUS较血管造影检出更多斑块突出(396例中33例 vs 396例中11例)。
  • 3项研究中IVUS导致48例中8例支架类型或尺寸改变,这些改变在血管造影中被遗漏。
  • 2项研究报告VH-IVUS与真实组织学的一致性良好,为80%至85%。

临床怎么用

  • 原文结论未据此给出具体临床推荐。

局限性

  • 作者认为需要大规模、最好是随机对照的研究来预测IVUS在决定临床结局方面的作用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Carotid plaque morphology plays an important role in determining outcome of carotid artery stenting (CAS). Intravascular ultrasound (IVUS) and its extension VH (Virtual Histology)-IVUS evaluate plaque characteristics in real time and guide decision making during stenting. To date, there is no consensus about indications of IVUS and its validated methods. This systematic review and meta-analysis aims to evaluate the clinical utility of IVUS in carotid artery interventions (CAS) and develop a future consensus for research and practice parameters. METHODS: A systematic review and meta-analysis was performed of the English literature articles published till February 2021. Studies reporting on IVUS parameters and findings and also its performance compared with other imaging modalities were included in review. Pooled prevalence with 95% confidence intervals (CI) was calculated. The statistical analysis was conducted in R version 3.6.2. RESULTS: A total of 2015 patients from 29 studies were included. Proportional meta-analysis was performed on 1566 patients from 11 studies. In 9 studies, stroke/transient ischemic attack (TIA) had a pooled prevalence of 4% (95% CI 3%-5%) while asymptomatic stroke had a pooled prevalence of 46% (95% CI 31%-62%) in 4 studies following IVUS. Two studies reported that IVUS detected more plaque protrusion compared with angiography (n=33/396 vs 11/396). IVUS led to stent type or size change in 8 of 48 cases which were missed on angiography in 3 other studies. Concordance between VH-IVUS and true histology was good at 80% to 85% reported in 2 studies. CONCLUSIONS: This systematic review and meta-analysis showed, though IVUS fared better to computed tomography (CT)/magnetic resonance (MR) angiography for better stent selection during CAS, with low to moderate risk of bias in the studies included. However, large scale, preferably randomized controlled studies are needed to predict its role in determining clinical outcome.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Mishra B, Pandit AK, Miyachi S, et al. Clinical Utility of Intravascular Ultrasound (IVUS) in Carotid Artery Interventions: A Systematic Review and Meta-analysis. J Endovasc Ther. 2021. PMID: 34955053. doi:10.1177/15266028211064824

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。