应用动脉血流评估预测颈动脉内膜切除术中阻断诱导的脑缺血
研究在156例颈动脉内膜切除术患者中,于阻断前直接测量颈总动脉血流,评估直接动脉血流比值对阻断期间体感诱发电位下降的预测价值。结果显示仅直接动脉血流比值在两组间有显著差异(P = 0.011),比值≤0.58可预测脑缺血。
要点
- 156例颈动脉内膜切除术患者中30例出现阻断期间体感诱发电位下降。
- 直接动脉血流比值(颈内动脉血流/颈总动脉血流)≤0.58可预测脑缺血。
- 直接动脉血流比值是唯一在两组间有显著差异的参数(P = 0.011)。
核心结论
- 使用超声血流计直接测量动脉血流有助于在颈动脉内膜切除术中颈动脉阻断前预测脑缺血。
研究设计与样本
- 研究纳入2013年4月至2020年3月期间的156例颈动脉内膜切除术患者,于阻断前直接测量颈总动脉血流(直接动脉血流),并评估术前磁共振成像解剖信息、氙增强计算机断层扫描脑血流及体表颈动脉回声的颈动脉收缩期峰值流速。
- 术中监测短潜伏期体感诱发电位,将阻断期间振幅下降≥50%定义为脑缺血的指标;手术在全身麻醉下进行,所有病例均插入分流管。
主要发现
- 156例颈动脉内膜切除术患者中,30例在阻断期间出现体感诱发电位下降。
- 有无体感诱发电位下降的患者之间,基线特征及术中、术后结果无显著差异。
- 在评估的参数中,仅直接动脉血流比值(颈内动脉血流/颈总动脉血流)在两组间有显著差异(P = 0.011)。
- 直接动脉血流比值≤0.58可预测颈动脉内膜切除术中的脑缺血。
关键数值与推荐
- 阻断期间体感诱发电位振幅下降≥50%被视为脑缺血的指标。
- 直接动脉血流比值≤0.58可预测颈动脉内膜切除术中的脑缺血。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Cross-clamping during carotid endarterectomy (CEA) is associated with the risk of cerebral ischemia. Various studies have evaluated different criteria for detecting cerebral ischemia, but difficulties arise when ischemic changes appear after the carotid artery is cross-clamped and incised. Here, we explored a parameter that can predict cerebral ischemia prior to cross-clamping during CEA using a blood-flow meter. METHODS: The carotid arterial blood flow was measured directly (direct ABF) in the common carotid artery prior to cross-clamping. The anatomical information in preoperative magnetic resonance imaging, cerebral blood flow in xenon-enhanced computed tomography, and carotid peak systolic flow velocity by carotid echo from the skin surface were also evaluated. A decrease in the short-latency somatosensory evoked potentials (SSEP) during cross-clamping to insert a shunt was assessed, and a decrease in amplitude of ≥ 50% was considered an indicator for cerebral ischemia. Surgery was performed under general anesthesia, and a shunt was inserted in all cases. RESULTS: Of 156 CEA patients between April 2013 and March 2020, 30 had decreased SSEP during cross-clamping. The baseline characteristics and intra- and postoperative findings were not significantly different between patients with and without a decrease in SSEP. Among the evaluated parameters, only the direct-ABF ratio (ABF-internal carotid artery/ABF-common carotid artery) differed significantly between the 2 groups (P = 0.011). The direct-ABF ratio ≤ 0.58 was predictive of cerebral ischemia during CEA. CONCLUSIONS: Direct-ABF measurement with an ultrasonic blood-flow meter can be useful for predicting cerebral ischemia prior to carotid artery cross-clamping during CEA.
引用
- Ishikawa T, Yamaguchi K, Funatsu T, et al. Prediction of Cross-Clamp-Induced Cerebral Ischemia During Carotid Endarterectomy Using Arterial Blood Flow Assessment. Ann Vasc Surg. 2021. PMID: 34954039. doi:10.1016/j.avsg.2021.11.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。