文献速递外周动脉疾病

血管内冲击波碎石术在下肢外周动脉疾病中的疗效与安全性:系统评价与荟萃分析

Efficacy and Safety of Intravascular Lithotripsy in Lower Extremity Peripheral Artery Disease: A Systematic Review and Meta-Analysis.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2021-12-06

该系统评价与荟萃分析纳入9项研究、共681例患者(769处病变),评估血管内冲击波碎石术(IVL)治疗下肢外周动脉疾病(PAD)的疗效与安全性。IVL前后直径狭窄减少59.3%(95%CI 53.30%-65.31%),限流性或D/E/F型夹层发生率仅1.25%(95%CI 0.60%-2.61%),支架置入汇总事件率为15.89%(95%CI 5.22%-39.34%)。作者认为IVL是钙化斑块修饰的有效安全方法,但不推荐常规使用,需更高质量证据进一步阐明其疗效。

要点

  • IVL前后直径狭窄减少59.3%(95%CI 53.30%-65.31%)。
  • 限流性或D/E/F型夹层发生率仅1.25%(95%CI 0.60%-2.61%)。
  • 支架置入汇总事件率为15.89%(95%CI 5.22%-39.34%)。

核心结论

  • 该荟萃分析支持IVL是下肢PAD钙化斑块修饰的有效安全方法,直径狭窄减少59.3%(95%CI 53.30%-65.31%),血管并发症极少。
  • 作者认为不推荐常规使用该器械,需更高质量证据阐明IVL在不同临床特征(如病变位置和长度)下及与其他治疗方式(如斑块旋切术)比较的疗效。

研究设计与样本

  • 按照系统评价与荟萃分析首选报告条目(PRISMA)声明进行荟萃分析。
  • 使用PubMed、Web of Sciences、OvidSP和EMBASE以预设检索词进行系统文献检索。
  • 共纳入9项研究,涵盖681例因PAD接受IVL的患者(769处病变)。

主要发现

  • 75.53%(95%CI 66.08%-83.03%)的病变报告为严重钙化。
  • IVL前后直径狭窄比较显示直径狭窄减少59.3%(95%CI 53.30%-65.31%)。
  • 限流性或D/E/F型夹层发生于仅1.25%(95%CI 0.60%-2.61%)的病例。
  • 支架置入的总体汇总事件率为15.89%(95%CI 5.22%-39.34%)。

临床怎么用

  • 作者认为不推荐常规使用该器械;需更高质量证据阐明IVL在不同临床特征(如病变位置和长度)下及与其他治疗方式(如斑块旋切术)比较的疗效。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Intravascular lithotripsy (IVL) is a novel technique for plaque modification during endovascular revascularisation for peripheral artery disease (PAD) with severe calcification. The aim of this paper was to perform a systematic review and meta-analysis of contemporary data to elucidate the efficacy and safety of IVL in lower extremity PAD. DATA SOURCES: A systematic literature search with pre-defined search terms was performed using PubMed, Web of Sciences, OvidSP, and EMBASE. REVIEW METHODS: A meta-analysis was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Patient characteristics, lesion calcification, pre-IVL and post-IVL diameter stenosis, complications, and stent rates were evaluated. RESULTS: Nine studies were included, encompassing a total of 681 patients (769 lesions) with IVL performed for PAD, of which 75.53% (95% confidence interval [CI] 66.08% - 83.03%) of the lesions were reported to have severe calcification. Comparison between pre-IVL and post-IVL diameter stenosis demonstrated a diameter stenosis reduction of 59.3% (95% CI 53.30% - 65.31%). Vascular complications were rare, with flow limiting or type D/E/F dissection occurring in only 1.25% (95% CI 0.60% - 2.61%) of cases. The overall pooled event rate for stent placement was 15.89% (95% CI 5.22% - 39.34%). CONCLUSION: This meta-analysis supports IVL as an effective and safe approach for calcified plaque modification in lower extremity PAD, achieving a diameter stenosis reduction of 59.3% (95% CI 53.30% - 65.31%) with minimal vascular complications. Routine use of this device is not recommended; further high quality evidence is required to elucidate the efficacy of IVL with respect to different clinical characteristics such as lesion location and length, and in comparison with other treatment modalities such as atherectomy.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Wong CP, Chan LP, Au DM, et al. Efficacy and Safety of Intravascular Lithotripsy in Lower Extremity Peripheral Artery Disease: A Systematic Review and Meta-Analysis. Eur J Vasc Endovasc Surg. 2021. PMID: 34887206. doi:10.1016/j.ejvs.2021.10.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。