GoBack导管首次用于下肢动脉复杂慢性完全闭塞成功穿通的经验
这项回顾性单中心研究分析了2018年5月至2020年7月间连续100例患者共101次下肢动脉血运重建,所有病例导丝穿通失败且均为慢性完全闭塞。GoBack导管总体技术成功率为92.1%,30天不良肢体事件包括小截肢4例(4.0%)、大截肢1例(1.0%)和再闭塞7肢(6.9%)。
要点
- GoBack导管用于下肢动脉复杂慢性完全闭塞再通,总体技术成功率92.1%。
- 病变中位长度24 cm,38例(37.6%)PACSS钙化分级为4或5级。
- 30天不良肢体事件:小截肢4例(4.0%)、大截肢1例(1.0%)、再闭塞7肢(6.9%)。
核心结论
- 新型GoBack导管为广泛外周血管介入中的复杂慢性完全闭塞再通提供多种腔内应用方式,技术成功率高且并发症率低。
研究设计与样本
- 回顾性单中心研究,分析2018年5月至2020年7月间使用研究器械的连续100例患者共101次下肢动脉血运重建。
主要发现
- 病变中位长度24 cm,38例患者(37.6%)外周动脉钙化评分系统(PACSS)钙化分级为4或5级。
- 20.8%的患者治疗了闭塞支架,慢性完全闭塞累及股腘段91.1%、髂动脉5.9%、胫动脉7.9%。
- GoBack导管用于进入或穿通慢性完全闭塞或闭塞支架的部分或全长,以及内膜下穿通后重返真腔。
- 器械经对侧和同侧顺行及逆行入路使用,总体技术成功率为92.1%。
- 3例患者在穿通或重返真腔部位发生轻微出血,均保守处理。
临床怎么用
- 作者认为,新型GoBack导管为广泛外周血管介入中的复杂慢性完全闭塞再通提供多种腔内应用方式,技术成功率高且并发症率低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the use of the GoBack-catheter (Upstream Peripheral Technologies) in complex revascularizations in lower limb arteries. MATERIALS AND METHODS: In this retrospective single-center study, the results of the first 100 consecutive patients including 101 limb-revascularizations, performed between May 2018 and July 2020 with the study device, were analyzed. In all cases, guidewire-crossing failed, and all lesions were chronic total occlusions (CTO), either de novo, reocclusions, or in-stent reocclusions. Successful crossing was defined as passing the CTO using the study device. Patency at discharge and after 30 days was defined as less than 50% restenosis on duplex sonography, without target lesion revascularization. RESULTS: Median lesion length was 24 cm and 38 patients (37.6%) had a calcium grading according to the peripheral arterial calcium scoring system (PACSS) of 4 or 5. In 20.8% of patients, an occluded stent was treated. CTOs involved the femoropopliteal segment in 91.1%, iliac arteries in 5.9%, and tibial arteries in 7.9%. The GoBack-catheter was employed for entering into or crossing through parts or the full length of a CTO or an occluded stent as well as for re-entering into the true lumen after subintimal crossing. The device was used via contralateral and ipsilateral antegrade as well as retrograde access with an overall technical success rate of 92.1%. In 3 patients minor bleeding occurred at the crossing or re-entry site, which were managed conservatively. Thirty-day adverse limb events comprised minor amputations in 4 patients (4.0%), 1 major amputation (1.0%), and reocclusions in 7 limbs (6.9%). CONCLUSION: The new GoBack-catheter offers versatile endovascular applicability for complex CTO recanalization in a broad range of peripheral vascular interventions with a high technical success and low complication rate.
引用
- Bakker O, Bausback Y, Wittig T, et al. First Experience With The GoBack-Catheter For Successful Crossing of Complex Chronic Total Occlusions in Lower Limb Arteries. J Endovasc Ther. 2021. PMID: 34964369. doi:10.1177/15266028211065962
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。