复合手术室能否提高肾下腹主动脉腔内移植物近端释放的准确性
本回顾性单中心研究纳入2015年1月至2019年3月连续接受肾下腹主动脉分叉型腔内移植物(EVAR)的患者,比较复合手术室(HOR组)与移动式二维透视成像系统(非HOR组)近端释放准确性。HOR组近端释放更准确,但两组「近端锚定区」相关并发症无差异。
要点
- HOR组近端释放距离中位数更短(多变量模型P=0.022)。
- HOR组与非HOR组「近端锚定区」相关并发症无差异(单变量分析P=0.620)。
- HOR组随访时间中位数25[14-28]个月,非HOR组36[23-44]个月(P<0.001)。
核心结论
- 复合手术室使肾下腹主动脉腔内移植物近端释放更准确,但两组「近端锚定区」相关并发症无差异。
研究设计与样本
- 回顾性单中心分析,纳入2015年1月至2019年3月连续接受EVAR的患者,按手术是否在复合手术室(HOR组)或使用移动式二维透视成像系统(非HOR组)分组。
- 共纳入93例患者(87%男性,中位年龄73岁),HOR组49例,非HOR组44例。
主要发现
- 术前CTA分析示两组近端锚定区中位长度相似,但中位主动脉直径(P=0.012)和中位β夹角(P=0.027)不同。
- HOR组近端释放距离中位数更短(多变量模型,P=0.022)。
- HOR组与非HOR组「近端锚定区」相关并发症无差异(单变量分析,P=0.620)。
- HOR组和非HOR组随访时间中位数分别为25[14-28]个月和36[23-44]个月(P<0.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This work aims to evaluate the impact of hybrid rooms and their advanced tools on the accuracy of proximal deployment of infrarenal bifurcated endograft (EVAR). METHODS: A retrospective single center analysis was conducted between January 2015 and March 2019 including consecutive patients that underwent EVAR. Groups were defined whether the procedure was performed in a hybrid operating room (HOR group) or using a mobile 2D fluoroscopic imaging system (non-HOR group). The accuracy of the proximal deployment was estimated by the distance (mm) between the bottom of the lowest renal artery (LwRA) origin and the endograft radiopaque markers parallax (LwRA/EDG distance) after curvilinear reconstruction. The impact of HOR on the LwRA/EDG distance was investigated using a multiple linear regression model. A composite "proximal neck"-related complications event was studied (Cox models). RESULTS: Overall, 93 patients (87 %male, median age 73 years) were included with 49 in the HOR group and 44 in the non-HOR group. Preoperative CTA analysis of the proximal neck exhibited similar median length, but different median aortic diameter (P = 0.012) and median beta angulation (P = 0.027) between groups. The median LwRA/EDG distance was shorter in the HOR group (multivariate model, P = 0.022). No difference in "proximal neck"-related complications was evidenced between the HOR and non-HOR groups (univariate analysis, P = 0.620). Median follow-up time was respectively 25 [14-28] and 36 months [23-44] in the HOR group and in the non-HOR group (P < 0.001). CONCLUSION: HOR offer more accurate proximal deployment of infrarenal endografts, with however no difference in "proximal neck"-related complications between groups.
引用
- Pruvot L, Lopez B, Patterson BO, et al. Hybrid Room: Does it Offer Better Accuracy in the Proximal Deployment of Infrarenal Aortic Endograft? Ann Vasc Surg. 2021. PMID: 34902466. doi:10.1016/j.avsg.2021.11.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。