复杂腹主动脉及胸腹主动脉瘤血管内修复中髂动脉分支内假体联合开窗主动脉覆膜支架的早期结果与技术要点
本文回顾性分析了单中心2015年9月至2020年6月接受开窗主动脉瘤修复(FEVAR)的连续患者,其中16例联合使用髂动脉分支内假体(IBE)以保留髂内动脉灌注。技术成功率100%,无围术期死亡,平均随访430天总生存率100%,无动脉瘤相关死亡,肢体通畅率100%。
要点
- FEVAR中联合IBE可保留髂内动脉灌注,早期结果令人鼓舞。
- 16例中单侧IBE 15例,双侧1例;技术成功率100%,无围术期死亡。
- 平均随访430天,总生存率100%,肢体通畅率100%,无3型内漏。
核心结论
- 在复杂腹主动脉瘤血管内修复中,将IBE与FEVAR联合使用可保留髂内动脉,早期结果令人鼓舞。
研究设计与样本
- 回顾性综述了2015年9月至2020年6月单中心连续接受FEVAR的患者,患者被评估为开放修复高风险。
- 开窗主动脉组件为医师改良或定制制造;特别审查了FEVAR中部署IBE的病例,解剖细节来自术前CT扫描。
主要发现
- 研究期间共171例患者接受FEVAR,其中15例单侧IBE植入,1例双侧IBE植入。
- 14例涉及医师改良开窗内假体,以及Zenith开窗支架联合Excluder分叉主体和IBE。
- 平均手术时间340.2分钟,平均透视时间65.4分钟;共纳入67个内脏肾靶血管(平均3.9,范围3-5)和15条髂内动脉,平均使用造影剂160 cc。
- 完成造影无1型和3型内漏;技术成功率100%;无围术期死亡;1例术后第2天发生脊髓缺血,神经功能恢复。
- 平均随访430天,总生存率100%,无动脉瘤相关死亡;肢体通畅率100%;无3型内漏,1例1B型内漏正在监测;1例因1C型肾分支支架内漏行再干预。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Concomitant iliac artery aneurysms can pose challenges during repair of complex abdominal and thoracoabdominal aortic aneurysms. In fenestrated aortic aneurysm repairs (FEVAR), preservation of internal iliac perfusion is important to minimize risk of spinal cord ischemia. Currently, most commonly used fenestrated stent grafts and the only approved iliac branch devices are manufactured by different companies in the United States. We report our experience with combining Iliac Branch Endoprosthesis (IBE) (W.L. Gore and Associates, Flagstaff, AZ) and fenestrated stent grafts, using the Zenith platform (Cook Medical, Bloomington, IN). METHODS: Retrospective review of consecutive patients who underwent FEVAR at a single institution from September, 2015 to June, 2020 was performed. Patients were deemed high-risk for open repair. Fenestrated aortic components implanted were either physician-modified or custom manufactured. Cases in which IBEs were deployed during FEVAR were specifically reviewed. Anatomic details were obtained from preoperative CT scans. Postoperative outcomes such as mortality, technical success, major adverse events, limb patency, limb-related endoleaks and re-intervention rates were assessed. RESULTS: During the study period, 171 patients underwent FEVAR at our institution. Among those, 15 patients had unilateral IBE implantation during FEVAR, while one received bilateral IBE implantation. Fourteen cases involved physician-modified fenestrated endograft, and Zenith Fenestrated (Cook Medical, Bloomington, IN) in combination with Excluder bifurcated main body and IBE (W.L. Gore and Associates, Flagstaff, AZ). Mean operative, and fluoroscopy times were 340.2 minutes, and 65.4 minutes respectively. A total of 67 viscerorenal target vessels (mean = 3.9, range =_3-5) and 15 internal iliac arteries were incorporated, with a mean of 160 cc contrast used. Completion angiograms were free of type 1 and type 3 endoleaks. Technical success was 100%. There was no perioperative mortality. One patient developed spinal cord ischemia post-operative day two with neurological recovery. At mean follow-up of 430 days, overall survival was 100% with no aneurysm-related mortalities. Limb patency remained 100%. There were no type 3 endoleaks while one patient had a type 1B endoleak that is currently being monitored. There was one re-intervention for type 1C renal branch graft endoleak. CONCLUSION: Combining IBE with FEVAR allows internal iliac preservation during endovascular repair of complex abdominal aortic aneurysms, with encouraging early results.
引用
- Zhang LL, Pyun A, Magee GA, et al. Early Results and Technical Tips of Combining Iliac Branch Endoprostheses with Fenestrated Aortic Stent Grafts during Endovascular Repair of Complex Abdominal and Thoracoabdominal Aortic Aneurysms. Ann Vasc Surg. 2021. PMID: 34933106. doi:10.1016/j.avsg.2021.11.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。