文献速递主动脉疾病

胸主动脉腔内修复术治疗胸主动脉医源性损伤

Thoracic Endovascular Aortic Repair for Iatrogenic Injury of the Thoracic Aorta.
PubMed 文献 · J Endovasc Ther · 2021-12-12

一例36岁特发性脊柱侧凸女性患者,T4至L3双侧椎弓根螺钉内固定术后10个月,CT血管造影显示左侧T5和T6经椎弓根螺钉分别突入胸降主动脉3 mm和5 mm。在血管外科与神经外科联合手术中,同期行胸主动脉腔内修复术(TEVAR)并取出侵入螺钉,术后第4天出院,两年血管造影显示TEVAR位置良好,无造影剂外渗或主动脉异常。作者认为,对于椎弓根螺钉导致的医源性主动脉损伤,同期TEVAR和脊柱螺钉取出是一种安全可行的治疗选择,可在不多次往返手术室的情况下完成脊柱重建。

要点

  • 椎弓根螺钉可突入胸降主动脉,CT血管造影可显示突出程度。
  • 同期TEVAR和脊柱螺钉取出可在一次手术中完成血管修复与脊柱重建。
  • 术后两年血管造影显示TEVAR位置良好,无造影剂外渗或主动脉异常。

核心结论

  • 对于椎弓根螺钉导致的医源性主动脉损伤,同期TEVAR和脊柱螺钉取出是一种安全可行的治疗选择,可在不多次往返手术室的情况下完成脊柱重建。

研究设计与样本

  • 病例报告:一例36岁特发性脊柱侧凸女性患者,T4至L3双侧椎弓根螺钉内固定术后10个月出现中段胸痛。

主要发现

  • CT血管造影显示左侧T5和T6经椎弓根螺钉分别突入胸降主动脉3 mm和5 mm。
  • 患者取右侧卧位,在血管外科与神经外科联合手术中成功置入TEVAR,同期经后路脊柱暴露取出侵入螺钉,神经外科同期完全翻修脊柱内固定。
  • 患者术后恢复良好,术后第4天出院。
  • 两年血管造影显示TEVAR位置良好,无造影剂外渗或主动脉异常。

临床怎么用

  • 作者认为,对于椎弓根螺钉导致的医源性主动脉损伤,同期TEVAR和脊柱螺钉取出是一种安全可行的治疗选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Address iatrogenic injury to the descending thoracic aorta by breached spinal screws through a novel approach of concomitant spinal screw removal and thoracic endovascular repair (TEVAR) placement. CASE REPORT: A 36-year-old female with idiopathic scoliosis underwent T4 to L3 bilateral pedicle instrumentation with spinal fusion and correction of scoliosis deformity. Ten months post-operative, she continued to complain of mid-thoracic pain; computed tomography (CT) angiography revealed protrusion of the left T5 and T6 transpedicular screws into her descending thoracic aorta by 3 and 5 mm, respectively. She was taken to the odds ratio (OR) in a combination case with vascular and neurosurgery. Positioned in the right lateral decubitus position, TEVAR was successfully deployed while neurosurgery concurrently removed the invading spinal screws via posterior spinal exposure. Neurosurgery then completely revised the spinal hardware during the same operation. The patient progressed well throughout the remainder of her hospital stay and was discharged on postoperative day 4. Two-year angiography demonstrated a well-placed TEVAR with no extravasation or aortic abnormality. CONCLUSIONS: In the setting of iatrogenic aortic injury due to pedicle screws, concomitant TEVAR and spinal screw removal is a safe and feasible treatment option that allows for spinal reconstruction to occur without multiple trips to the operating room.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Tharp P, King RW, Frankel BM, et al. Thoracic Endovascular Aortic Repair for Iatrogenic Injury of the Thoracic Aorta. J Endovasc Ther. 2021. PMID: 34894824. doi:10.1177/15266028211065968

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。