桡动脉头静脉吻合口长度对动静脉内瘘成熟的影响
回顾2015年3月至2018年12月接受桡动脉头静脉动静脉内瘘(RCAVF)侧端吻合术的114例患者,比较初始血液透析成功组与失败组,发现桡动脉头静脉吻合口长度与内瘘成熟率无统计学显著关联(P=0.55),而抢先建立内瘘、静脉直径和流量是初始透析成功的显著因素。
要点
- 114例RCAVF患者中初始血液透析成功83例(72.8%),失败31例(27.2%)。
- 桡动脉头静脉吻合口长度不是初始透析成功的显著因素(P=0.55)。
- 抢先建立内瘘(P=0.01)、静脉直径(P<0.001)和流量(P<0.001)与初始透析成功显著相关。
核心结论
- 桡动脉头静脉吻合口长度在统计学上不影响RCAVF的成熟率,但延长桡动脉切口可能提高初始血液透析成功率。
研究设计与样本
- 回顾性分析2015年3月至2018年12月接受侧端吻合方式建立RCAVF的患者,比较初始血液透析成功组与失败组的可能因素包括桡动脉头静脉吻合口长度。
主要发现
- 共114例患者接受RCAVF建立,其中男性72例(63.2%)、女性42例(36.8%)。
- 术前动脉切口长度平均为14.1 mm(范围11.0-16.0 mm)。
- 114例中初始血液透析成功83例(72.8%);初始血液透析失败31例(27.2%),其中球囊血管成形术成功17例、失败4例、未进行10例。
- 球囊血管成形术后二次成功率为87.7%。
- 因素分析显示抢先建立内瘘(P=0.01)、静脉直径(P<0.001)和流量(P<0.001)是初始血液透析成功的显著因素,而RCAVF的桡动脉头静脉吻合口长度不是显著因素(P=0.55)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A radiocephalic arteriovenous fistula (RCAVF) is associated with better long-term patency and fewer complications. However, RCAVF have lower maturation rate for hemodialysis compared with upper AVF or arteriovenous graft. We performed this study to determine the effect of the radiocephalic (RC) anastomotic length on the AVF maturation. METHODS: We reviewed the patients who underwent RCAVF creation with a side-to-end manner from March 2015 to December 2018. AVF maturation was defined as successful hemodialysis (HD) in at least two consecutive sessions. We compared the possible factors including the RC anastomotic length between the initial HD success group and initial HD failure group. RESULTS: A total of 114 patients underwent RCAVF creation: 72 males and 42 females (63.2% and 36.8%, respectively). The mean preoperative arteriotomy length of the AVF was 14.1 mm (range 11.0-16.0 mm). Out of 114 patients, initial HD was executed successfully in 83 patients (72.8%). Among the 31 patients with initial HD failure (27.2%) balloon angioplasty was successfully performed in 17 patients, failed in 4 patients, and not performed in 10 patients. The secondary success rate after balloon angioplasty was 87.7%. After factor analysis, pre-emptive AVF (P = 0.01), vein diameter (P < 0.001), and flow rate (P < 0.001) were revealed significant factors for initial HD success, but not RC anastomotic length of AVF (P = 0.55). CONCLUSION: The length of the radiocephalic anastomosis does not affect the RCAVF maturation rate statistically. However, lengthening of arteriotomy on the radial artery may increase the initial success rate of HD.
引用
- Ahn HY, Cho BS, Kim H, et al. Effect of Radiocephalic Anastomotic Length on the Maturation of Arteriovenous Fistula. Ann Vasc Surg. 2021. PMID: 34788706. doi:10.1016/j.avsg.2021.10.045
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。