文献速递主动脉疾病颈动脉与弓上血管

分支型与烟囱型腔内移植物在0区锚定行全腔内主动脉弓修复的结局比较

Comparison of the Outcomes of Total Endovascular Aortic Arch Repair Between Branched Endograft and Chimney Endograft Technique in Zone 0 Landing.
PubMed 文献 · J Endovasc Ther · 2021-11-20

单中心回顾性观察性队列研究纳入2010年1月至2020年3月40例不适合开放手术的主动脉弓疾病患者(分支型25例、烟囱型15例,中位年龄79岁),比较0区锚定全腔内修复结局;两种技术均可行,但烟囱型1a型内漏发生率显著更高,分支型围术期卒中率较高。

要点

  • 分支型与烟囱型0区锚定全腔内主动脉弓修复均可行,30天死亡率2.5%(1/40)。
  • 围术期卒中率10.0%(4/40),分支型16.0%(4/25)vs 烟囱型0%(0/15),p=0.278。
  • 1a型内漏率15.0%(6/40),烟囱型40.0%(6/15)vs 分支型0%(0/25),p=0.001。

核心结论

  • 对于不适合开放手术的高危主动脉弓疾病患者,分支型与烟囱型全腔内主动脉弓修复均可行。
  • 由于卒中率较高,需要严格的术前评估以预防卒中。
  • 烟囱型未观察到动脉瘤破裂,但由于1a型内漏发生率高,应仔细选择患者。

研究设计与样本

  • 单中心、回顾性、观察性队列研究。
  • 2010年1月至2020年3月纳入40例患者,分支型25例、烟囱型15例,中位年龄79岁,中位随访4.1年。
  • 患者均被认为不适合开放手术治疗。

主要发现

  • 所有手术成功,术后30天内无中转开放修复病例。
  • 30天死亡率2.5%(n=1;分支型0/25,0% vs 烟囱型1/15,6.7%;p=0.375)。
  • 围术期卒中率10.0%(n=4;分支型4/25,16.0% vs 烟囱型0/15,0%;p=0.278)。
  • 1a型内漏率15.0%(n=6;分支型0/25,0% vs 烟囱型6/15,40.0%;p=0.001)。
  • 8年生存率49.9%;8年无主动脉相关死亡率94.4%(分支型95.5% vs 烟囱型93.3%,p=0.504),8年无主动脉事件率60.7%(分支型70.7% vs 烟囱型40.0%,p=0.048)。

关键数值与推荐

  • 卒中危险因素为头臂动脉粥样斑块分级≥2(p<0.001)。
  • 1a型内漏危险因素为烟囱型技术(p=0.001)。

临床怎么用

  • 作者认为分支型与烟囱型全腔内主动脉弓修复可用于不适合开放手术的高危患者。
  • 作者指出因卒中率较高,需要严格术前评估以预防卒中。
  • 作者建议烟囱型患者应仔细选择,因1a型内漏发生率高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Zone 0 landing in thoracic endovascular aortic repair (TEVAR) has recently gained increasing attention for the treatment of high-risk patients. The aim of this study was to compare the outcomes of total endovascular aortic arch repair between branched TEVAR (bTEVAR) and chimney TEVAR (cTEVAR) in the landing zone (LZ) 0. MATERIALS AND METHODS: This was a single-center, retrospective, and observational cohort study. From January 2010 to March 2020, 40 patients (bTEVAR, n=25; cTEVAR, n=15; median age: 79 years) were enrolled in this study, with a median follow-up period of 4.1 years. These patients were considered unsuitable for open surgical treatment. RESULTS: All procedures were successful and no cases of conversion to open repair were noted during the 30-day postoperative period. The 30-day mortality was 2.5% (n=1; bTEVAR [0 of 25, 0%] vs cTEVAR [1 of 15, 6.7%]; p=0.375), the perioperative stroke rate was 10.0% (n=4; bTEVAR [4 of 25, 16.0%] vs cTEVAR [0 of 15, 0%], p=0.278), and type 1a endoleak rate was 15.0% (n=6; bTEVAR [0 of 25, 0%] vs cTEVAR [6 of 15, 40.0%], p=0.001). The risk factor for stroke was atheroma grade of ≥2 in the brachiocephalic artery (p<0.001). The risk factor for type 1a endoleak was cTEVAR (p=0.001). The 8-year survival rate was 49.9%. The aorta-related death-free rate and aortic event-free rate at 8 years were 94.4% (bTEVAR: 95.5% vs cTEVAR: 93.3%, p=0.504) and 60.7% (bTEVAR: 70.7% vs cTEVAR: 40.0%, p=0.048), respectively. CONCLUSIONS: Total endovascular aortic arch repair using bTEVAR and cTEVAR is feasible for the treatment of aortic arch diseases in high-risk patients who are unsuitable for open surgery. However, as the rate of stroke is high, strict preoperative evaluation to prevent stroke is needed. No rupture of the aneurysm was observed in cTEVAR, but patients should be selected carefully because of the high incidence of type 1a endoleak.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Kudo T, Kuratani T, Shirakawa Y, et al. Comparison of the Outcomes of Total Endovascular Aortic Arch Repair Between Branched Endograft and Chimney Endograft Technique in Zone 0 Landing. J Endovasc Ther. 2021. PMID: 34802327. doi:10.1177/15266028211059912

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。