靶内脏血管解剖构型对胸腹主动脉瘤腔内修复术后早期并发症的影响
本研究纳入2008至2020年本中心接受开窗或分支腔内修复的胸腹主动脉瘤患者54例(182根靶内脏支架),分析支架解剖构型与1年血栓及内漏的关系。排除分支病例后分析97根开窗支架,发现解剖构型与血栓无关,但与III型内漏相关。
要点
- 靶内脏支架解剖构型与1年内漏相关,与血栓无关。
- 发生内漏者支架更迂曲、离开移植物角度更大、支架起源更朝上。
- 分支病例因例数少被排除后仅分析开窗支架。
核心结论
- 靶内脏支架的解剖构型与开窗腔内修复术后1年III型内漏相关,但与血栓无关。
- 发生内漏的病例支架更迂曲、离开移植物的角度更大、支架起源更朝上。
研究设计与样本
- 单中心回顾性研究,纳入2008至2020年本中心因胸腹主动脉瘤接受开窗或分支腔内修复的患者54例(平均年龄72±713岁,原文此处表述有矛盾),共182根靶内脏支架(50根分支、132根开窗)。
- 术后1个月CT作为解剖参考,随访1年记录支架血栓和内漏,由三名独立观察者盲法分析。
主要发现
- 排除分支病例后分析97根开窗支架,观察到5例血栓和7例内漏。
- 分支病例支架更长、三维尾侧成角更大、ABC成角段更大。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Fenestrated and branched endovascular aortic repair (fEVAR-bEVAR) is a viable treatment option for thoracoabdominal aortic aneurysms but target visceral stent (TVS) endoleak and thrombosis remain a limiting factor. This study aims to evaluate TVS anatomy impact on 1-year risk of thrombosis and endoleak. METHODS: Patients treated with fEVAR-bEVAR for thoracoabdominal aneurysms between 2008 and 2020 in our centre were enrolled. We recorded comorbidities, operative details, 1-month postoperative CT scan (anatomical reference), and TVS behaviour: thrombosis and endoleak at 1-year follow-up. For each TVS, different points were identified using a centre-lumen-line: (A) TVS origin, (B) end of branch/fenestration, (C) visceral vessel entry, (D) end of TVS, (E) 1-cm distally. We analyzed TVS tortuosity ((centre-lumen-line/straight distance)-1, in %), image vector analysis of each segment in 2D (antero-posterior, left-right) and 3D (craneo-caudal displacement), and centre-lumen-line analysis (bending in ABC and CDE). Three independent observers performed a blind analysis, and anatomical differences between bEVAR/fEVAR, and cases with/without 1-year thrombosis and TVS endoleak, were compared using Kaplan-Meier curves (Log-Rank test), and t-test/Wilcoxon signed-ranks test respectively. RESULTS: Fifty-four patients (72 ± 713 years mean age; 182 TVS: 50 branches, 132 fenestrations) met the inclusion criteria. bEVAR cases had longer stents, with more caudal 3D angulation, and greater ABC angulated segment. After excluding bEVAR cases (low case number), 97 fEVAR TVS were analyzed. Five thrombosis and 7 endoleaks were observed. While anatomical configuration showed no association to thrombosis, it was related to endoleak: these cases presented more tortuous stents (5.97% ± 0.10, 21.40% ± 0,22, P = 0.011), with more angulated centre-lumen-line at ABC segment (5.69° ± 15.77°, 7.18° ± 7.77°, P = 0.012), and more upward-pointing stents in the origin of the stent (AB: 89.07° ± 24.46°, 109.09° ± 16.56°, P = 0.012; BC: 87.86° ± 21.10°, 113.11° ± 22.23°, P = 0.026). CONCLUSIONS: Anatomical configuration of the TVS is associated with type III endoleak, but not thrombosis, at 1-year following fEVAR. Cases with endoleak presented more tortuous stents, with a more angulated exit from the endograft, and upward-pointing of the origin of the stent.
引用
- Vigliotti RC, Mestres G, Ruiz Carmona C, et al. Impact of Target Visceral Vessel Anatomical Configuration on Early Complications Following Endovascular Repair of Thoracoabdominal Aortic Aneurysms. Ann Vasc Surg. 2021. PMID: 34788702. doi:10.1016/j.avsg.2021.10.044
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。