复杂性主动脉弓动脉瘤顺行原位分支支架移植术的早期临床结果
本研究评估了使用沟槽球囊技术的顺行原位分支支架移植术(RIBS)治疗复杂性主动脉弓动脉瘤(CAA)的早期结果,对30例高危患者行双RIBS(D-RIBS)重建左颈总动脉和头臂动脉。技术成功率为100%,30天死亡率为0%,术后脑梗死2例(6.7%),复发神经麻痹1例(3.3%)。作者认为早期结果可接受,沟槽球囊方法使开窗安全可靠,但需进一步研究和专用器械。
要点
- D-RIBS技术治疗高危CAA患者技术成功率100%,30天死亡率0%。
- 术后并发症包括脑梗死2例(6.7%)和复发神经麻痹1例(3.3%)。
- 随访中位14个月,12个月总生存率92.3%,无动脉瘤相关死亡。
核心结论
- 对于高危CAA患者,D-RIBS的早期临床结果可接受。
- 沟槽球囊方法能够实现安全可靠的开窗。
- 需要进一步研究和专用器械。
研究设计与样本
- 本研究为单臂研究,纳入30例高危患者,接受双RIBS(D-RIBS)使用沟槽球囊技术重建左颈总动脉和头臂动脉。
- 主要终点为技术成功和30天死亡率;次要终点为术后并发症、内漏率、总生存率、动脉瘤相关死亡和再干预。
主要发现
- 平均年龄77.1±6.6岁,平均最大短轴动脉瘤直径65.9±8.9 mm。
- 26例患者因择期弓部主动脉瘤行D-RIBS,4例为zone 2胸主动脉腔内修复失败后再干预。
- 从颈总动脉进行支架移植穿刺60次,所有病例技术成功(100%)。
- 术后并发症包括脑梗死2例(6.7%)和复发神经麻痹1例(3.3%);30天死亡率为0%。
- 中位随访14个月(6-56个月),12个月总生存率为92.3%,无动脉瘤相关死亡;观察到1b型和2型内漏各1例,无再干预。
临床怎么用
- 作者认为对于高危CAA患者,D-RIBS的早期临床结果可接受。
- 作者认为沟槽球囊方法能够实现安全可靠的开窗。
- 作者指出需要进一步研究和专用器械。
局限性
- 需要进一步研究和专用器械。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the early outcomes of retrograde in situ branched stent grafting (RIBS) using the gutter balloon technique for complex aortic arch aneurysms (CAAs). METHODS: The RIBS technique is an in situ needle fenestration procedure during thoracic endovascular aortic repair with the reconstruction of cervical branches. The double RIBS (D-RIBS) for the reconstruction of the left common carotid artery and the brachiocephalic artery using the gutter balloon technique was performed in 30 high-risk patients. We describe the early clinical results of the D-RIBS technique for CAAs. Primary end points were technical success and 30-day mortality. Secondary end points were postoperative complications, rates of endoleaks, overall survival, aneurysm-related death, and reinterventions. RESULTS: The mean age was 77.1 ± 6.6 years, and the mean maximum minor-axis aneurysmal diameter was 65.9 ± 8.9 mm. Twenty-six patients underwent D-RIBS for elective arch aortic aneurysm, and four patients were for reintervention after zone 2 thoracic endovascular aortic repair failure. Stent graft puncture was performed 60 times from the common carotid arteries, and technical success was achieved in all cases (100%). Postoperative complications included cerebral infarction in two patients (6.7%) and recurrent nerve palsy in one patient (3.3%). The 30-day mortality was 0%. During the median follow-up period of 14 months (6-56 months), overall survival at 12 months was 92.3% without any aneurysm-related death. Type 1 b and type 2 endoleaks were observed in one each, and no reintervention was encountered. CONCLUSIONS: Early clinical outcomes of the D-RIBS for high-risk patients with CAAs are acceptable. The gutter balloon method enables safe and reliable fenestration. Further studies and dedicated devices are warranted.
引用
- Ohki T, Maeda K, Baba T, et al. Early clinical outcomes of retrograde in situ branched stent grafting for complex aortic arch aneurysms. J Vasc Surg. 2021. PMID: 34742885. doi:10.1016/j.jvs.2021.10.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。