文献速递主动脉疾病

使用AneurysmFlow对体内腹主动脉瘤模型的血流模式进行实时评估

Real-Time Evaluation of Blood Flow Patterns Using AneurysmFlow for an in vivo Abdominal Aortic Aneurysm Model.
PubMed 文献 · Ann Vasc Surg · 2021-11-06

本研究利用AneurysmFlow可视化功能分析37例腹主动脉瘤患者的数字减影血管造影图像,将血流模式分为层流或湍流并评估边界层分离。结果显示,腔内血栓管腔占据比越大,动脉瘤越倾向于层流模式(P=0.03)且越可能不存在边界层分离(P=0.04);肾下主动脉颈至主动脉分叉的血流速度与腔内血栓管腔占据比呈正相关(P<0.001)。

要点

  • 腔内血栓管腔占据比越大,腹主动脉瘤越倾向于层流模式(P=0.03)。
  • 腔内血栓管腔占据比越大,越可能不存在边界层分离(P=0.04)。
  • 肾下主动脉颈至主动脉分叉的血流速度与腔内血栓管腔占据比呈正相关(P<0.001)。

核心结论

  • 使用AneurysmFlow对腹主动脉瘤进行实时个体化模型血流动力学分析,显示血流模式和血流速度随腔内血栓不同而变化。
  • 这种使用AneurysmFlow的新型分析方法有可能在获取腹主动脉瘤有临床意义的血流动力学信息方面发挥重要作用。

研究设计与样本

  • 研究纳入37例腹主动脉瘤患者,使用AneurysmFlow的可视化功能分析其数字减影血管造影图像。
  • 将血流模式分类为层流或湍流,并评估是否存在边界层分离。
  • 获取造影剂从肾下主动脉颈至主动脉分叉的时间以计算血流速度。
  • 评估包括腔内血栓管腔占据比在内的动脉瘤特征与血流动力学模式之间的关联。

主要发现

  • 以腔内血栓管腔占据比为自变量的逻辑回归分析显示,腔内血栓管腔占据比越大,动脉瘤越倾向于层流模式(P=0.03)。
  • 腔内血栓管腔占据比越大,越可能不存在边界层分离(P=0.04)。
  • 线性回归分析显示,肾下主动脉颈至主动脉分叉的血流速度与腔内血栓管腔占据比呈正相关(P<0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Many new tools for abdominal aortic aneurysm (AAA) rupture risk evaluation have been developed. These new tools need detailed hemodynamic information in AAA. However, hemodynamic data obtained from in vivo research are lacking. Thus, the objective of this study was to analyze blood flow patterns in an in vivo AAA model to acquire real-time hemodynamic information using AneurysmFlow, a novel flow evaluation system. METHODS: Digital subtraction angiography images of patients who underwent endovascular aneurysm repair were analyzed using the visualization function of the AneurysmFlow to classify blood flow patterns as laminar or turbulent flow. The presence of boundary layer separation was also evaluated. The time taken for contrast medium to travel from the infrarenal aortic neck to aortic bifurcation was acquired to calculate the flow velocity. Associations between characteristics of aneurysm including lumen occupying ratio of intraluminal thrombus (ILT) and the hemodynamic flow pattern were evaluated. RESULTS: A total of 37 AAA patients was enrolled. Their blood flow patterns were evaluated using the AneurysmFlow. Logistic regression analyses with lumen occupying ratio of ILT as an independent variable showed that the larger the lumen occupying ratio of ILT, the more likely the aneurysm was to show a laminar pattern (P = 0.03), and the more likely the boundary layer separation would not exist (P = 0.04). The flow velocity from the infrarenal aortic neck to the aortic bifurcation showed a positive association with the lumen occupying ratio of the ILT in linear regression analysis (P < 0.001). CONCLUSIONS: Hemodynamic analysis of AAA with the AneurysmFlow using real-time individual patient models showed different flow patterns and flow velocities depending on ILT. This novel analytic approach using AneurysmFlow has potential to play an important role in obtaining clinically meaningful hemodynamic information of AAA.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Park YJ, Mok SK, Park SC, et al. Real-Time Evaluation of Blood Flow Patterns Using AneurysmFlow for an in vivo Abdominal Aortic Aneurysm Model. Ann Vasc Surg. 2021. PMID: 34752852. doi:10.1016/j.avsg.2021.08.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。