新型虹吸输尿管通道鞘可改善肾内压与灌注流量
本研究在体外幻影肾模型中比较新型虹吸输尿管通道鞘(UAS)与传统UAS。结果显示新型11/13F鞘的灌注流量显著高于传统11/13F和12/14F鞘,且稳态肾内压为0 mmHg,而传统鞘分别为20 mmHg和13 mmHg。提示该新型UAS具有降低肾内压并增加灌注流量的临床潜力。
要点
- 新型虹吸UAS的灌注流量显著高于传统11/13F和12/14F鞘。
- 新型UAS稳态肾内压为0 mmHg,传统11/13F和12/14F分别为20和13 mmHg。
- 体外模型提示新型UAS可在增加流量的同时降低肾内压。
核心结论
- 体外评估表明新型虹吸UAS相比更大直径的传统UAS能降低肾内压并显著增加灌注流量,具有临床潜力。
研究设计与样本
- 采用 validated phantom kidney with fibre optic pressure sensing capabilities 进行体外实验。
- 通过输尿管软镜以标准化80 cmH2O压力灌注,比较传统11/13F和12/14F UAS与新型11/13F虹吸UAS。
主要发现
- 传统11/13F UAS灌注流量为19.3 mL/min,新型为29.3 mL/min(P < 0.001)。
- 传统12/14F UAS灌注流量为22.7 mL/min,新型为29.3 mL/min(P = 0.002)。
- 稳态肾内压传统11/13F为20 mmHg,12/14F为13 mmHg,新型为0 mmHg。
临床怎么用
- 在软性输尿管镜碎石术中,该新型UAS可能有助于降低肾内压并改善灌注流量。
局限性
- 研究为体外幻影肾模型,结论需临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To describe a novel syphoning ureteric access sheath (UAS) intended for use during flexible ureterorenoscopy (URS). We aimed to assess if in vitro it could reduce intrarenal pressure (IRP) and increase irrigant flow compared to traditional UASs. MATERIALS AND METHODS: A validated phantom kidney with fibre optic pressure sensing capabilities was used to assess the IRP. Standardised 80 cmH2 O irrigation via a ureterorenoscope was instilled through traditional UASs (11/13 and 12/14 F) and compared to the novel 11/13-F syphoning UAS. The measured minute volume, calculated hourly flow volume, and steady state IRP were compared. RESULTS: The traditional 11/13 and 12/14-F UASs had statistically poorer irrigant flow than the novel syphoning UAS, at 19.3 vs 29.3 mL/min (P < 0.001) and 22.7 vs 29.3 mL/min (P = 0.002), respectively. The steady state IRP was 20 mmHg for the traditional 11/13 F and 13 mmHg for the 12/14 F compared to 0 mmHg for the novel UAS. CONCLUSION: The described novel UAS is different from traditional devices by incorporating a syphon mechanism. Our in vitro assessment demonstrates that the novel UAS holds clinical potential to reduce IRP while allowing a significant increase in irrigant flow compared to larger diameter traditional UASs.
引用
- Lazarus J, Kaestner L. Novel syphon ureteric access sheath has the potential to improve renal pressures and irrigant flow. BJU Int. 2021. PMID: 34496125. doi:10.1111/bju.15593