文献速递泌尿系结石

基于术中内镜数字图像的纯与混合泌尿系结石自动识别

Towards automatic recognition of pure and mixed stones using intra-operative endoscopic digital images.
PubMed 文献 · BJU Int · 2021-07-14

本研究评估深度学习卷积神经网络(CNN)在临床环境中利用术中内镜图像自动识别纯与混合肾结石形态特征的可行性。单中心前瞻性研究纳入347个结石表面和236个结石剖面观察,CNN对纯Ia/COM的预测准确率在表面和剖面图像中分别为91%和94%,对混合型结石也能部分区分其成分。研究表明CNN是识别结石成分的有前景方法。

要点

  • CNN对纯Ia/COM结石的表面和剖面图像预测准确率分别为91%和94%。
  • 纯IIIb/UA结石使用表面图像获得最高灵敏度98%。
  • 混合Ia/COM+IIb/COD中,表面图像预测Ia/COM为84%、IIb/COD为70%、两者同时为65%。

核心结论

  • 深度学习CNN可从术中内镜图像中识别纯与混合肾结石成分,是计算机辅助诊断的有前景方法。

研究设计与样本

  • 单中心前瞻性研究,由20年经验泌尿外科医生术中检查所有肾结石表面和剖面,收集形态学标准生成标注数据集,训练深度CNN预测纯与混合结石成分。

主要发现

  • 共纳入347个结石表面观察和236个结石剖面观察,约80%结石仅一种形态类型,约20%显示两种。
  • 纯IIIb/UA使用表面图像灵敏度最高达98%。
  • 纯Ia/COM最常见,表面和剖面图像分别正确预测91%和94%。
  • 混合Ia/COM+IIb/COD中,表面图像预测Ia/COM为84%、IIb/COD为70%、两者同时为65%。
  • 混合Ia/COM+IIIb/UA中,剖面图像预测Ia/COM为91%、IIIb/UA为69%、两者同时为74%。

临床怎么用

  • 术中内镜图像经CNN分析可提供结石形态信息,辅助成分诊断。

局限性

  • 本研究为初步研究,需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess automatic computer-aided in situ recognition of the morphological features of pure and mixed urinary stones using intra-operative digital endoscopic images acquired in a clinical setting. MATERIALS AND METHODS: In this single-centre study, a urologist with 20 years' experience intra-operatively and prospectively examined the surface and section of all kidney stones encountered. Calcium oxalate monohydrate (COM) or Ia, calcium oxalate dihydrate (COD) or IIb, and uric acid (UA) or IIIb morphological criteria were collected and classified to generate annotated datasets. A deep convolutional neural network (CNN) was trained to predict the composition of both pure and mixed stones. To explain the predictions of the deep neural network model, coarse localization heat-maps were plotted to pinpoint key areas identified by the network. RESULTS: This study included 347 and 236 observations of stone surface and stone section, respectively; approximately 80% of all stones exhibited only one morphological type and approximately 20% displayed two. A highest sensitivity of 98% was obtained for the type 'pure IIIb/UA' using surface images. The most frequently encountered morphology was that of the type 'pure Ia/COM'; it was correctly predicted in 91% and 94% of cases using surface and section images, respectively. Of the mixed type 'Ia/COM + IIb/COD', Ia/COM was predicted in 84% of cases using surface images, IIb/COD in 70% of cases, and both in 65% of cases. With regard to mixed Ia/COM + IIIb/UA stones, Ia/COM was predicted in 91% of cases using section images, IIIb/UA in 69% of cases, and both in 74% of cases. CONCLUSIONS: This preliminary study demonstrates that deep CNNs are a promising method by which to identify kidney stone composition from endoscopic images acquired intra-operatively. Both pure and mixed stone composition could be discriminated. Collected in a clinical setting, surface and section images analysed by a deep CNN provide valuable information about stone morphology for computer-aided diagnosis.

来源:BJU Int,查看原文。版权归原作者所有。

引用

  1. Estrade V, Daudon M, Richard E, et al. Towards automatic recognition of pure and mixed stones using intra-operative endoscopic digital images. BJU Int. 2021. PMID: 34133814. doi:10.1111/bju.15515

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。