机器人辅助根治性前列腺切除术中荧光共聚焦显微镜数字冰冻切片技术
本研究前瞻性纳入24例接受机器人辅助根治性前列腺切除术的患者,术中采用荧光共聚焦显微镜对神经血管邻近切缘的剥离标本进行快速数字成像评估。所有患者最终病理显示神经血管邻近区域切缘阴性,其中4例因术中阳性而行二次切除后转阴;该技术可能作为NeuroSAFE的替代方案,在不影响肿瘤学安全的前提下优化功能结局。
要点
- 荧光共聚焦显微镜可术中快速评估前列腺切缘,图像类似HE染色。
- 24例患者神经血管邻近切缘最终病理均阴性,4例二次切除后转阴。
核心结论
- 机器人辅助根治性前列腺切除术中采用荧光共聚焦显微镜数字冰冻切片评估切缘,可能作为NeuroSAFE的替代方案,在不影响肿瘤学安全的前提下优化功能结局。
研究设计与样本
- 前瞻性研究,纳入24例接受机器人辅助根治性前列腺切除术并经术中荧光共聚焦显微镜控制切缘状态的患者。
主要发现
- 所有患者神经血管邻近区域剥离标本最终组织病理学切缘均为阴性。
- 4例患者接受了二次局灶性切除,最终切缘状态转为阴性。
- 5例术前有勃起功能的患者中4例恢复了性功能。
关键数值与推荐
- 术中采用Mohs技术从新鲜前列腺剥离切缘:取尖部及左右后外侧三个切片。
- 荧光共聚焦显微镜立即获取剥离标本数字图像并与远程病理学家共享。
- 切缘阳性时可因荧光共聚焦显微镜能在平面样本上定位感兴趣区域而行神经血管束的局灶二次切除。
临床怎么用
- 术中可对神经血管邻近切缘行荧光共聚焦显微镜快速评估,阳性时行局灶二次切除以转为阴性。
- 该技术可能帮助在保留功能的同时确保肿瘤学安全,但需进一步验证。
局限性
- 原文未报告该技术与NeuroSAFE的直接比较数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Robot-assisted radical prostatectomy (RARP) involves a tradeoff between oncological control and functional outcomes. Intraoperative control of surgical margins (SMs) may help in ensuring the safety of the dissection. Fluorescence confocal microscopy (FCM) is an effective method for interpretation of prostate tissue and provides digital images with an appearance similar to hematoxylin-eosin staining. OBJECTIVE: To describe an alternative technique to NeuroSAFE for intraoperative evaluation of neurovascular-adjacent margins shaved from ex vivo specimens using FCM analysis. DESIGN, SETTING, AND PARTICIPANTS: This was a prospective study of 24 patients undergoing RARP with intraoperative FCM control of margin status. SURGICAL PROCEDURE: After surgical dissection, SMs are sectioned from the fresh prostate using the Mohs technique (shaving): three slices from the apex and the right and left posterolateral aspects are obtained. Digital images of the shavings are immediately acquired via FCM and shared with a remote pathologist. In the case of a positive SM, a focal secondary resection of the bundle can be performed owing to the ability of FCM to locate a region of interest on the flat sample. MEASUREMENTS: The primary outcome measure was the rate of negative margins at neurovascular-adjacent sites. Oncological and functional outcomes for patients with 1 yr of follow-up are also reported. RESULTS AND LIMITATIONS: All patients had negative SMs in shavings from neurovascular-adjacent areas at final histopathology; four underwent a secondary resection with final conversion to negative SM status. Nine of ten patients with 1-yr follow-up are free of biochemical recurrence (prostate-specific antigen persistence in one pN1 case), nine are fully continent, and four of the five with preoperative potency have recovered their sexual function. CONCLUSIONS: Digital frozen sections with FCM during RARP may represent an alternative to NeuroSAFE for possible optimization of functional outcomes without compromising oncological safety. PATIENT SUMMARY: We developed a technique to ensure complete removal of cancer tissue during surgical removal of the prostate. Tissue specimens are examined via digital microscopy in real time during the operation. This allows the surgeon to remove more tissue if cancer is detected at the margins of a specimen, while avoiding unnecessary removal of healthy tissue.
引用
- Rocco B, Sarchi L, Assumma S, et al. Digital Frozen Sections with Fluorescence Confocal Microscopy During Robot-assisted Radical Prostatectomy: Surgical Technique. Eur Urol. 2021. PMID: 33965288. doi:10.1016/j.eururo.2021.03.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。