文献速递泌尿系结石膀胱癌与上尿路尿路上皮癌肾癌与肾肿瘤

三团注CT尿路造影在血尿评估中减少辐射剂量的随机对照试验

Comparison of Conventional and Triple Bolus Computerized Tomographic Urography Protocols for Radiation Dose Reduction in Hematuria Evaluation: A Randomized Controlled Trial.
PubMed 文献 · J Urol · 2021-02-19

三团注方案仅需2次扫描,辐射暴露较常规4次扫描方案降低33%(1,145 vs 1,715 mGy*cm,p<0.001),且两组对泌尿系统病变的检出率无差异。

要点

  • 三团注CT尿路造影较常规方案辐射剂量降低33%,病变检出率相当。
  • 肉眼血尿病变检出率:三团注70% vs 常规73%(p=0.72)。
  • 镜下血尿病变检出率:三团注59% vs 常规50%(p=0.68)。

核心结论

  • 在肉眼和镜下血尿评估中,三团注CT尿路造影显著降低辐射暴露,同时提供与常规CT相当的泌尿生殖系统病变检出。
  • 上尿路充盈缺损的检测能力未专门测试。

研究设计与样本

  • 前瞻性随机对照试验,纳入肉眼或镜下血尿患者,常规CT组100例,三团注CT组100例。
  • 三团注方案:2次扫描(平扫+3次对比剂注射后第二次扫描);常规方案:4次扫描(平扫+皮髓质期、肾实质期、排泄期)。

主要发现

  • 三团注CT辐射暴露较常规CT降低33%(1,145 vs 1,715 mGy*cm,p<0.001)。
  • 肉眼血尿病变检出率:三团注70%,常规73%(p=0.72)。
  • 镜下血尿病变检出率:三团注59%,常规50%(p=0.68)。
  • 两组间尿路结石、肾囊肿、泌尿系统肿块、膀胱病变和前列腺病变的检出率均无差异。

临床怎么用

  • 在血尿评估中可考虑采用三团注CT尿路造影方案以减少辐射暴露,同时保持病变检出能力。

局限性

  • 上尿路充盈缺损的检测能力未专门测试。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Computerized tomographic urography is the diagnostic tool of choice for evaluating hematuria. In keeping with the ALARA (As Low As Reasonably Achievable) principle, we evaluated a triple bolus computerized tomography protocol designed to reduce radiation exposure. MATERIALS AND METHODS: Patients with macroscopic or microscopic hematuria were prospectively randomized to conventional computerized tomography (100) or triple bolus computerized tomography (100). The triple bolus computerized tomography protocol entails 2 scans: pre-contrast scan followed by 3 contrast injections at 40 seconds, 60 seconds and 20 minutes prior to the second scan to capture all 3 phases. The conventional computerized tomography protocol requires 4 scans: pre-contrast scan, and 3 post-contrast scans at the corticomedullary, nephrographic and excretory phases. Radiation exposure and the detection of urological pathology were recorded based on radiology reports. RESULTS: There were no differences in patient demographics or body mass index between the 2 groups. Triple bolus computerized tomography exposed patients to 33% less radiation (1,715 vs 1,145 mGy*cm for conventional vs triple bolus computerized tomography; p <0.001). For macroscopic hematuria, the pathology detection rates were 70% for triple bolus and 73% for conventional computerized tomography (p=0.72). For microscopic hematuria, the detection rates were 59% for triple bolus and 50% for conventional computerized tomography (p=0.68). In both groups, the rates of detection of urolithiasis, renal cysts, urological masses, bladder pathology and prostate pathology were no different between triple bolus and conventional computerized tomography. CONCLUSIONS: In both the settings of macroscopic and microscopic hematuria evaluation, triple bolus computerized tomography significantly reduces radiation exposure while providing equivalent detection of genitourinary pathology compared to conventional computerized tomography. The ability to detect upper tract filling defects was not specifically tested.

来源:J Urol,查看原文。版权归原作者所有。

引用

  1. Karani R, Sung JM, Xie L, et al. Comparison of Conventional and Triple Bolus Computerized Tomographic Urography Protocols for Radiation Dose Reduction in Hematuria Evaluation: A Randomized Controlled Trial. J Urol. 2021. PMID: 33605796. doi:10.1097/JU.0000000000001603

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。