多孔da Vinci Xi与单孔da Vinci SP机器人根治性前列腺切除术围手术期结局的倾向性评分分析
结果显示SP组总手术时间和控制台时间均显著更长,但出血>100ml的比例显著更低,两组并发症、疼痛评分和切缘阳性率无显著差异。
要点
- SP组总手术时间中位差14分钟(95%CI 9-19),控制台时间中位差5分钟(95%CI 0-5),均显著更长。
- SP组出血>100ml的比例显著更低(差27%,95%CI 12-42%)。
- 两组并发症、疼痛评分及切缘阳性率无显著差异,SP组前列腺外侵犯比例更高(差16%,95%CI 4.6-27%)。
核心结论
- SP机器人用于根治性前列腺切除术在初始学习阶段安全有效,围手术期性能满意,但需长期随访评估功能与肿瘤学结局。
研究设计与样本
- 单中心前瞻性收集2019年6月至2020年4月行根治性前列腺切除术的患者数据,SP组71例,Xi组875例,经倾向性评分匹配后各71例进行比较。
- 匹配协变量包括年龄、BMI、Charlson合并症指数、SHIM评分、AUA症状评分、前列腺体积、PSA、Gleason评分、D'Amico风险分组及神经保留程度。
主要发现
- SP组总手术时间中位差14分钟(95%CI 9-19),控制台时间中位差5分钟(95%CI 0-5),均显著更高。
- SP组出血>100ml的比例显著更低(差27%,95%CI 12-42%)。
- 两组均无术中或术后并发症报告,6、12、18小时疼痛评分及切缘阳性率无显著差异。
- SP组前列腺外侵犯比例显著更高(差16%,95%CI 4.6-27%)。
- 随访期间无生化复发;45天控尿率差异11%(95%CI -5.6%至28%),勃起功能率差异-7.3%(95%CI -21%至6.2%)。
临床怎么用
- 在初始学习阶段,SP机器人可安全有效地完成根治性前列腺切除术,但手术时间较长,需注意出血量优势与前列腺外侵犯比例较高的差异。
局限性
- 功能和肿瘤学结局的比较随访时间较短,中位随访SP组4.4月、Xi组3.2月。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Use of the single-port da Vinci SP robotic platform for various urological procedures has been described by several groups. However, the comparative performance of the SP robot in relation to earlier models such as the da Vinci Xi is still unclear. OBJECTIVE: To compare intraoperative and short-term postoperative outcomes between the da Vinci Xi and SP robots for patients undergoing radical prostatectomy (RP) in a referral center. DESIGN, SETTING, AND PARTICIPANTS: Data were prospectively collected for patients undergoing RP from June 2019 to April 2020 in a single center. The da Vinci SP was used for 71 patients and the da Vinci Xi for 875 patients. After propensity score (PS) matching, two groups of 71 patients were selected for the comparative study. INTERVENTION: RP via a transperitoneal approach using the same technique steps and anatomy access with both robot consoles. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: A PS analysis was performed using the covariates age, body mass index, Charlson comorbidity index, Sexual Health Inventory for Men score, American Urological Association symptom score, prostate size, prostate-specific antigen levels, Gleason score, D'Amico risk group, and degree of nerve-sparing. Intraoperative performance and short-term functional (continence and potency) and oncological outcomes were compared between the groups. RESULTS AND LIMITATIONS: Median follow-up was 4.4 mo (interquartile range [IQR] 1.6-7.2) for the SP group and 3.2 mo (IQR 1.6-4.8) for the Xi group (p = 0.2). The median total operative time and median console time were both significantly higher in the SP group, with median differences of 14 min (95% confidence interval [CI] 9-19) and 5 min (95% CI 0-5), respectively. The proportion of patients with blood loss of >100 ml was significantly lower in the SP group (difference of 27%, 95% CI 12-42%). No intra- or postoperative complications were reported in either group. There were no significant differences in pain scores at 6, 12, and 18 h or in positive surgical margin rates between the groups. The SP group had a significantly higher percentage of extraprostatic extension than the Xi group (difference of 16%, 95% CI 4.6-27%). None of the patients experienced biochemical recurrence during follow-up. The difference in continence rates at 45 d between the SP and Xi groups was 11% (95% CI -5.6% to 28%) and the difference in potency rates at 45 d was -7.3% (95% CI -21% to 6.2%). The short-term follow-up for comparison of functional and oncological outcomes is a limitation. CONCLUSIONS: Despite differences in trocar placement and technology between the two da Vinci consoles, the SP has satisfactory intraoperative performance compared to the Xi. SP surgery can be performed safely and effectively during the initial learning phase. However, longer-term follow-up is needed to provide further evidence on the impact of SP implementation on functional and oncological outcomes. PATIENT SUMMARY: We compared intraoperative and short-term postoperative outcomes for patients who underwent radical prostatectomy using two different robots, the da Vinci Xi and the single-port da Vinci SP. We found that operative time was longer for the Single Port console. Studies with long-term follow-up are needed to compare the functional and oncological outcomes.
引用
- Moschovas MC, Bhat S, Sandri M, et al. Comparing the Approach to Radical Prostatectomy Using the Multiport da Vinci Xi and da Vinci SP Robots: A Propensity Score Analysis of Perioperative Outcomes. Eur Urol. 2020. PMID: 33357994. doi:10.1016/j.eururo.2020.11.042
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。